Regulations and standards
8
4
Regulations and standards
4-1 UL
Standards
This product is recognized by UL under the UL Standards.
Applicable standard
Certifi cation body
Standards File No.
UL 508C
UL
E171462
4-2 EU
Directive
CE Marking
This product is affixed the CE Marking under the Low Voltage Directive and EMC Directive.
Low Voltage Directive
Applicable standards
EN 61800-5-1
Installation condition
(EN Standards)
To be incorporated in equipment.
Overvoltage category: II
Pollution degree: 2
Degree of protection: IP20 (Pulse input type)
IP10 (Built-in controller type,
Pulse input type with RS-485 communication interface)
Protection against electric shock: Class I
This product cannot be used in IT power distribution systems.
Install the product within the enclosure in order to avoid contact with hands.
When a product can be touched with hands, be sure to ground. Make sure to ground the Protective Earth Terminals
of the motor and driver.
To protect against electric shock using an earth leakage breaker (RCD), connect a type B earth leakage breaker to
the primary side of the driver.
When using a circuit breaker (MCCB), use a unit conforming to the EN or IEC standard.
Isolate the motor cable, power-supply cable and other drive cables from the signal cables (CN1, CN5) by means of
double insulation.
The temperature of the driver's heat sink may exceed 90 °C (194 °F) depending on the driving conditions.
Accordingly, take heed of the following items:
• Do not touch the driver.
• Do not use the driver near flammable objects.
• Always conduct a trial operation to check the driver temperature.
EMC Directive
This product is conducted EMC testing under the conditions specifi ed in “Example of motor and driver installation and
wiring” on p.27. The conformance of your mechanical equipment to the EMC Directive will vary depending on such
factors as the configuration, wiring and layout for other control system devices and electrical parts used with this
product. It therefore must be verified through conducting EMC measures in a state where all parts including this
product have been installed in the equipment.
Applicable Standards
EMI
EN 55011 Group1 Class A, EN 61000-6-4, EN 61800-3, EN 61000-3-2, EN 61000-3-3
EMS
EN 61000-6-2, EN 61800-3
This equipment is not intended for use in residential environments nor for use on a low-
voltage public network supplied in residential premises, and it may not provide
adequate protection to radio reception interference in such environments.