Guidance
35
10 Guidance
If you are new to the
AZ
Series, read this section to understand the operating methods along with the operation fl ow.
How to read the guidance
This chapter explains the operation procedure as follows.
Connection (
p.35)
Home position setting (
p.36) *
* Perform the home position setting only once
initially. Once the home position is set, it is no
need to set afterward.
Trial operation (
p.38)
Positioning operation (
p.40)
High-speed return-to-home operation (
p.41)
10-1
Connection
Wire the driver by reference to the fi gure. Be sure to connect a control power supply (24 VDC).
The following explanation is an example for when the built-in controller type driver of single-phase 200-240 VAC is
used.
Connect to MOTOR
Connect to +24V, 0V
Cable for motor
Connect to ENCODER
Cable for encoder
Main power supply
Single-phase 200-240 VAC
Move the motor to a desired
home position manually.
CN1 connector
Control power
supply (24 VDC)
PC in which the
MEXE02
has been installed
+24V
0V
Required
Required
Grounding
* Cables represented in gray color are accessories. Use the cable for encoder when the length of the encoder cable of
motor is not enough.