Setting
32
Address number (slave address)
Set the address number (slave address) using the address number setting switch (ID) and SW1-No.1 of the function
setting switch. Make sure each address number (slave address) you set for each driver is unique.
Factory setting
Built-in controller type; ID: 0, SW1-No.1: OFF
Pulse input type with RS-485 communication interface; ID: 1, SW1-No.1: OFF
ID
SW1-No.1
Address number
(slave address)
ID
SW1-No.1
Address number
(slave address)
0
OFF
0 *
0
ON
16
1
1
1
17
2
2
2
18
3
3
3
19
4
4
4
20
5
5
5
21
6
6
6
22
7
7
7
23
8
8
8
24
9
9
9
25
A
10
A
26
B
11
B
27
C
12
C
28
D
13
D
29
E
14
E
30
F
15
F
31
* In the case of Modbus protocol, the address number (slave address) 0 is reserved for broadcasting, so do not use this
address.
Transmission rate
Set the transmission rate using transmission rate setting switch (BAUD).
The transmission rate to be set should be the same as the transmission rate of the master controller.
Factory setting
Built-in controller type; 7
Pulse input type with RS-485 communication interface; 4
BAUD
Transmission rate (bps)
0
9600
1
19200
2
38400
3
57600
4
115,200
5
230,400
6
Not used.
7
Network converter
8 to F
Not used.
Do not set BAUD to positions 6 and 8 to F.