4 Installation
-
15
-
4.5 Installing and wiring in compliance with EMC
directive
General
•
EMC Directive
The
AXH
series has been designed and manufactured for incorporation in general
industrial machinery. The EMC directive requires that the equipment incorporating
this product comply with these directives.
The installation and wiring method for the motor and driver are the basic methods
that would effectively allow the customer’s equipment to be compliant with the
EMC directive.
The compliance of the final machinery with the EMC directive will depend on such
factors as configuration, wiring, layout and risk involved in the control-system
equipment and electrical parts. It there fore must be verified through EMC measures
by the customer of the machinery.
•
Applicable Standards
EMI Emission
Tests EN
61000-6-4
EMS Immunity
Tests EN
61000-6-2
Installing and wiring
Effective measures must be taken against the EMI that the
AXH
series may give to
adjacent control-system equipment, as well as the EMS of the
AXH
series itself, in
order to prevent a serious functional impediment in the machinery.
The use of the following installation and wiring methods will enable the
AXH
series
to be compliant with the EMC directive (the aforementioned compliance standards).
•
About power source
The
AXH
series products are of the DC power-input specification.
Use a DC power supply (such as a switching power supply) that is optimally
compliant with the EMC directive.
•
Motor cable connection
When extending the motor cable, use the optional extension cable. The maximum
extension distance including the cable length of the motor itself should be 2 m
(6.6 ft.).
Option model
Applicable unit type
CC02AXH
[1.5 m (4.9 ft.)]
AXH015
type,
AXH230
type,
AXH450
type
CC02AXH2
[1.5 m (4.9 ft.)]
AXH5100
type
∗
It is also possible to use
FC02HBL
[1.5 m (4.93 ft.)] for the lead wire type of
AXH230
and
AXH450
.