Parameter R/W commands
4 P
ar
82
8-6
ABZO sensor setting parameters
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
2032
07F0h
Mechanism settings
0: Prioritize ABZO setting
1: Manual setting
0
D
2034
07F2h
Initial coordinate generation & wrap
coordinate setting
0: Prioritize ABZO setting
1: Manual setting
0
D
2035
07F3h
Mechanism limit parameter setting
0: Follow ABZO setting
1: Disable
0
D
2036
07F4h
Mechanism protection parameter setting
0: Follow ABZO setting
1: Disable
0
D
2037
07F5h
JOG/HOME/ZHOME operation setting
0: Prioritize ABZO setting
1: Manual setting
0
D
8-7
Mechanism settings parameters
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
448
01C0h
Electronic gear A
1 to 65,535
1
C
449
01C1h
Electronic gear B
1 to 65,535
1
450
01C2h
Motor rotation direction
0: Positive side=Counterclockwise
1: Positive side=Clockwise
2: Positive side=Counterclockwise
(the driver parameter is applied)
3: Positive side=Clockwise
(the driver parameter is applied)
1
C
2017
07E1h
Mechanism lead pitch
1 to 32,767
1
C
2033
07F1h
Gear ratio setting
0: Gear ratio setting disable
1 to 32,767: Gear ratio (1=0.01)
0
C
2553
09F9h
Mechanism lead decimal
digit setting
0: ×1 [mm]
1: ×0.1 [mm]
2: ×0.01 [mm]
3: ×0.001 [mm]
0
C
8-8
Initial coordinate generation & wrap coordinate parameters
Parameter ID
Name
Setting range
Initial
value
Update
Dec
Hex
455
01C7h
Wrap setting
0: Disable
1: Enable
1
C
457
01C9h
Initial coordinate generation & wrap
setting range
Refer to p.83. (1=0.1 rev)
10
C
459
01CBh
Initial coordinate generation & wrap range
offset ratio
0 to 10,000 (1=0.01 %)
5,000
C
460
01CCh
Initial coordinate generation & wrap range
offset value
−536,870,912 to 536,870,911 steps
0
C
461
01CDh
The number of the RND-ZERO output in
wrap range
1 to 536,870,911 divisions
1
C
Summary of Contents for AlphaStep AZ Series
Page 14: ...1 Introduction 14...
Page 34: ...2 Hardware 34...
Page 118: ...6 Reference materials 118...
Page 119: ...6 Reference materials 119...