Connection
2 Har
29
z
Example of installation and wiring
Host controller
Main
power supply
Noise
filter
Control
power supply
Noise
filter
AC
AC
Motor
Driver *1
Grounded panel
Power supply cable
(shielded cable)
Connection cable *2
Cable clamp
is a shield box.
is a ferrite core.
symbol indicate the grounding.
Cable
clamp
Cable
clamp
*1 The driver is grounded by making the heat sink contact directly with the grounded panel.
*2 An Oriental Motor cable is used.
•
The driver uses components that are sensitive to static electricity. Take measures against static
electricity since static electricity may cause the driver to malfunction or suffer damage.
•
When connecting the following products, cover the motor cable with a shielded braided sleeving.
Use the cable clamps to ground both ends of the shielded braided sleeving.
−
AZ
Series:
AZM14
,
AZM15
,
AZM24
,
AZM26
−
EAC
Series:
EACM2
−
EAS
Series:
EASM2
−
DR
Series:
DR20
,
DR28
−
DGII
Series:
DGM60
−
EH
Series:
EH3
,
EH4
Summary of Contents for AlphaStep AZ Series