Parameter R/W commands
4 P
ar
82
* It is used to set the voltage mode of the main power supply. The voltage mode of the main power supply is
discriminated in 50 ms after the main power supply is turned on. Set the “Main power mode” parameter to
"0: 24 VDC" or "1: 48 VDC" when the main power supply starts up slowly or the voltage of the main power supply is
unstable.
8-3
Coordinate parameters
Parameter ID
Name
Setting range
Initial value
Update
Dec
Hex
451
01C3h
Software overtravel
−1: Disable
0: Immediate stop
1: Deceleration stop
2: Immediate stop with alarm
3: Deceleration stop with alarm
3
A
452
01C4h
Positive software limit
−2,147,483,648 to 2,147,483,647 steps
2,147,483,647
A
453
01C5h
Negative software limit
−2,147,483,648 to 2,147,483,647 steps
−2,147,483,648
A
454
01C6h
Preset position
−2,147,483,648 to 2,147,483,647 steps
0
A
8-4
Operation parameters
Parameter ID
Name
Setting range
Initial
value
Update
Dec
Hex
322
0142h
Starting speed
0 to 4,000,000 Hz
500
B
327
0147h
Acceleration/deceleration unit
0: kHz/s
1: s
2: ms/kHz
0
C
328
0148h
Permission of absolute positioning without
setting absolute coordinates
0: Disable
1: Enable
0
B
8-5
Direct data operation parameters
Parameter ID
Name
Setting range
Initial
value
Update
Dec
Hex
272
0110h
Direct data operation zero
speed command action
0: Deceleration stop command
1: Speed zero command
0
B
24852
6114h
Direct data operation trigger
setting
−6: Operation type
−5: Position
−4: Speed
−3: Starting/changing rate
−2: Stopping deceleration
−1: Operating current
0: Disable
1: Apply all data
1
A