THE MAIN UNIT

The main unit gives you all the readings and controls. It should be
placed  indoors.

The main unit is powered up by the 12V AC adapter.

To install it,

1.Position  the  main  unit  and  other  units  within  effective  range

(100 meters).

2.Insert  four  UM3  or  “AA”-sized  alkaline  batteries  for  backup

purposes

.

3.Mount  the  main  unit  safely  in  place.  Or  use  its  table  stand  to

place it on a flat surface.

4.Connect the AC power adapter to the main unit and a wall socket.

5.Press the [RESET] button on the main unit to initiate operation.

The  main  unit  will  start  searching  for  signals  for  about  four
minutes. Upon successful reception, the readings will be displayed.
The main unit will update the readings at regular intervals.

Note:

 

If

 the main unit is operating solely on battery power, the EL

backlight and RS232 connection will be disabled. 

To connect the

main unit to the PC, the AC power adaptor must be connected.

LOW-BATTERY WARNING

There  are  low-battery  indicators 

[

]

  for  the  main  unit,  rain

gauge, baro-thermo-hygrometer, thermo-hygrometer and optional
remote  thermo  and  thermo-hygro  sensors.  Replace  the  batteries
when  the  respective  indicators  light  up.

Note:

 The readings collected from the thermo-hygrometer and any

optional remote thermo and thermo-hygro sensors share the same
display window. The “OUT” and remote channel will share the same
low-battery  indicator.  When  the  battery  level  of  the  thermo-
hygrometer is low, the low-battery indicator will turn on. If it is one
of  the  optional  remote  sensors,  the  low-battery  indicator  will
blink. To locate the channel in question, press the window to scan
through all available devices. The low-battery indicator will stop
blinking if the battery level is low for that one.

SECTION  3  OPERATION

THE MAIN UNIT

A.

WEATHER    FORECAST    AND    BAROMETRIC    READING
WINDOW

B.

INDOOR    TEMPERATURE    WINDOW

C.

INDOOR    HUMIDITY    WINDOW

D.

OUTDOOR/CHANNEL    TEMPERATURE    WINDOW

E.

OUTDOOR/CHANNEL     HUMIDITY    WINDOW

F.

RAINFALL    WINDOW

G.

RF  CALENDAR  CLOCK  AND  DAILY  ALARM  WINDOW

H.

WIND SPEED    AND    DIRECTION    WINDOW

I.

CHANNEL    BUTTON

J.

MEMORY    BUTTON

K.

ALARM    BUTTON

L.

SET    BUTTON

M.

UNIT    BUTTON

N.

ALARM    ON/OFF    BUTTON

O.

 

]  BUTTON

P.

 

]  BUTTON

Q.

[ RESET]   BUTTON

R.

RS232  SERIAL  PORT

S.

DC 12V JACK

Summary of Contents for WMR928NX

Page 1: ...ransmitter STR938 The WMR928NX can support up to seven different remote instruments You can also connect up to three optional thermo or thermo hygro sensors to the system Optional items include Thermo hygro sensor THGR228N THGR238N Thermo sensor THR228N THR238N Contact an authorized dealer for optional items SECTION 2 INSTALLATION The WMR928NX operates at 433MHz No wire installation is required am...

Page 2: ...the rain collector to check the leveling 5 Use metal ring to adjust the leveling of the rain collector if necessary 6 Close the cover of the rain collector THE SOLAR TRANSMITTERS The solar transmitters make use of solar energy to power the instruments they are connected to Note It is recommended to insert two UM3 or AA sized super lithium batteries for sub zero weather conditions For the solar tra...

Page 3: ...gauge baro thermo hygrometer thermo hygrometer and optional remote thermo and thermo hygro sensors Replace the batteries when the respective indicators light up Note The readings collected from the thermo hygrometer and any optional remote thermo and thermo hygro sensors share the same display window The OUT and remote channel will share the same low battery indicator When the battery level of the...

Page 4: ...flash 4 Use and to change to the desired setting 5 Press SET for minutes setting 6 Use and to change to the desired setting 7 Press SET to confirm Note the window will show if no alarm is armed Once set the alarm clock will be activated automatically and the alarm indicator will light up When an alarm goes off press any button to stop it The alarm is still active and will go off again the next day...

Page 5: ...ory is clear INDOOR HUMIDITY The current indoor relative humidity taken by the indoor baro thermo hygrometer is displayed on the indoor hygrometer window To display the maximum minimum and current humidity 1 Press the indoor humidity window 2 Press MEMORY repeatedly for the desired record The time and date of the record will also be displayed alternatively with STAMP icon in the clock window To cl...

Page 6: ...tting will be displayed OUTDOOR AND CHANNEL HUMIDITY The relative humidity readings taken by the outdoor thermo hygrometer and separate thermo hygro sensors are displayed on the outdoor channel humidity window As this window can display up to four different sets of data specify the instrument or channel you want to read To do so 1 Press the outdoor channel humidity window 2 Press CHANNEL to go fro...

Page 7: ...r receive the signal from those sensors 2 If you have disconnected signals you cannot clear the memory THE RESET BUTTON This button is only used when the system is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button The main unit will return to all default settings and start searching for signals again Before resetting the main unit you should do the same f...

Page 8: ... Scientific products such as digital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes contact information for our customer care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the i...

Reviews: