Oregon Scientific WMR928NX User Manual Download Page 8

8

 E

N

Wind Chill Temperature

Measuring  Range

: -52°C to 60°C (-61.6°F to 140°F)

Resolution

: 1°C (2°F)

Rainfall

Daily  and  Cumulative

:  0 to 9999 mm (0 to 393.7 in)

Measuring  Range

Rainfall Rate

: 0 to 999 mm/hr (0 to 39.37 in/hr)

Measuring  Range

Daily  and  Cumulative

: 1 mm (0.04 inch)

Resolution

Rainfall  Rate  Resolution

: 1mm/hr (0.04 m/h) typical

WMR928NX

 :

Weight

: 505  g

Dimension

: 204 (L) x 139 (W) x 39 (H)

Power

: 12V  AC / DV adapter

Power backup

: 4 x UM3 - “AA” size alkaline battery

WGR918N :

Weight

: 430  g

Dimension

: 295 (L) x 116.5 (W) x 550 (H)

Power

: solar cell (STR938)

THGR918N :

Weight

: 111.5  g

Dimension

: 113.5 (L) x 42.5 (W) x 107.5 (H)

Power : Main

: solar cell (STR928N)

PCR918N :

Weight

: 276  g

Dimension

:       113.5 x 145 (H)

Power  : Main

: sole cell (STR928N)

BTHR918N :

Weight

: 78.4 g

Dimension

: 180 (L) x 70 (W) x 19 (H)

Power

: 4 x UM4 - “AAA” size alkaline battery

STR928N :

Weight

: 266  g

Dimension

: 115 (L) x 81 (W) x 141 (H)

Power back up

: 2 x UM3- “AA” size  alkaline battery

(recommend super lithium battery for
weather condition under  0°C)

STR938 :

Weight

: 290  g

Dimension

: 115 (L) x 81 (W) x 138 (H)

Power back up

: 2 x UM3- “AA” size  alkaline battery

(recommend super lithium battery for
weather condition under  0°C)

CAUTION

— The content of this manual is subject to change without

further  notice.

— Due  to  printing  limitation,  the  displays  shown  in  this

manual may differ from the actual display.

— The  contents  of  this  manual  may  not  be  reproduced

without the permission of the manufacturer.

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more about
Oregon Scientific products such as digital cameras; MP3 players;
children's  electronic  learning  products  and  games;  projection
clocks;  health  and  fitness  gear;  weather  stations;  and  digital  and
conference phones. The website also includes contact information
for our customer care department in case you need to reach us, as
well  as  frequently  asked  questions  and  customer  downloads.

We hope you will find all the information you need on our website,
however  if  you'd  like  to  contact  the  Oregon  Scientific  Customer
Care department directly, please visit www2.oregonscientific.com/
service/support or call 949-608-2848 in the US. For international
enquiries,  please  visit  www2.oregonscientific.com/about/
international/default.asp

EC-DECLARATION OF CONFORMITY

This  product  contains  the  approved  transmitter  module  that
complies with the essential requirements of Article 3 of the R&TTE
1999  /  5  /  EC  Directive,  if  used  as  intended  and  the  following
standards  have  been  applied:

Safety of information technology equipment

(Article 3.1.a of the R&TTE Directive)

Applied  Standard

EN 60950-1:  2001

Electromagnetic compatibility

(Article 3.1.b of the R&TTE Directive)

Applied  Standards

ETSI EN 301 489-1-3 (Ver.1.4.1) :  2002-08

Efficient use of radio frequency spectrum

(Article 3.2 of the R&TTE Directive)

Applied  Standards

ETSI EN 300 220-3 (Ver1.1.1) :  2000-09

Additional  information:

The product herewith complies with the requirements of the Low
Voltage Directive 73 / 23 / EC, the EMC Directive 89 / 336 / EC and
carries the CE marking accordingly.

Carmelo  Cubito

Agrate Brianza (MI) / Italy January 2004

Manufacturer’s EU R&TTE  Representative

COUNTRIES  RTTE  APPROVAL  COMPLIED

                       All EC countries, Switzerland   CH

and Norway     N

Summary of Contents for WMR928NX

Page 1: ...ransmitter STR938 The WMR928NX can support up to seven different remote instruments You can also connect up to three optional thermo or thermo hygro sensors to the system Optional items include Thermo hygro sensor THGR228N THGR238N Thermo sensor THR228N THR238N Contact an authorized dealer for optional items SECTION 2 INSTALLATION The WMR928NX operates at 433MHz No wire installation is required am...

Page 2: ...the rain collector to check the leveling 5 Use metal ring to adjust the leveling of the rain collector if necessary 6 Close the cover of the rain collector THE SOLAR TRANSMITTERS The solar transmitters make use of solar energy to power the instruments they are connected to Note It is recommended to insert two UM3 or AA sized super lithium batteries for sub zero weather conditions For the solar tra...

Page 3: ...gauge baro thermo hygrometer thermo hygrometer and optional remote thermo and thermo hygro sensors Replace the batteries when the respective indicators light up Note The readings collected from the thermo hygrometer and any optional remote thermo and thermo hygro sensors share the same display window The OUT and remote channel will share the same low battery indicator When the battery level of the...

Page 4: ...flash 4 Use and to change to the desired setting 5 Press SET for minutes setting 6 Use and to change to the desired setting 7 Press SET to confirm Note the window will show if no alarm is armed Once set the alarm clock will be activated automatically and the alarm indicator will light up When an alarm goes off press any button to stop it The alarm is still active and will go off again the next day...

Page 5: ...ory is clear INDOOR HUMIDITY The current indoor relative humidity taken by the indoor baro thermo hygrometer is displayed on the indoor hygrometer window To display the maximum minimum and current humidity 1 Press the indoor humidity window 2 Press MEMORY repeatedly for the desired record The time and date of the record will also be displayed alternatively with STAMP icon in the clock window To cl...

Page 6: ...tting will be displayed OUTDOOR AND CHANNEL HUMIDITY The relative humidity readings taken by the outdoor thermo hygrometer and separate thermo hygro sensors are displayed on the outdoor channel humidity window As this window can display up to four different sets of data specify the instrument or channel you want to read To do so 1 Press the outdoor channel humidity window 2 Press CHANNEL to go fro...

Page 7: ...r receive the signal from those sensors 2 If you have disconnected signals you cannot clear the memory THE RESET BUTTON This button is only used when the system is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button The main unit will return to all default settings and start searching for signals again Before resetting the main unit you should do the same f...

Page 8: ... Scientific products such as digital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes contact information for our customer care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the i...

Reviews: