The main unit, when connected to the AC power, is equipped with
an automatic backlight. Every time you press a window on the main
unit,  the 

  backlight  will  come  on  for  a  few  seconds.  This

function  will  be  disabled  for  sole  battery  operation.  The 
backlight will also come on for a few seconds when the alarm is
triggered.

THE RF CALENDAR CLOCK

The  calendar  clock  is  radio-controlled.  It  automatically
synchronizes  its  current  time  and  date  when  it  is  brought  within
range of the radio signal generated from Frankfurt, Germany (DCF77).

You can also set the calendar clock manually.

To do so,

1.Press the RF calendar clock and alarm window.

2.Press and hold [ 

 

] to disable the radio reception function.

3.Press and hold [SET] 

until

 the digit 

flashes

.

4.Use [ 

 

] and [ 

 

] to change to the desired setting.

5.Press [SET] for the next item setting.

6.Repeat from Step 4 to finish all the settings for:

-

Clock display formats (12hr or 24hr)

-

Display language of the day-of-the-week

-

Clock

-

Calendar display formats (Month-Day, Day-Month)

-

Calendar

For the display language, you can choose:

-

English (E)

-

German (D)

-

French (F)

-

Italian (I)

-

Spanish (S)

7.Press [SET] to confirm.

The  calendar  clock  and  alarm  window  has  three  displays:  clock
with seconds, clock with day-of-the-week and calendar. To change
from one display to another, press the window once.

THE DAILY ALARM

To set the daily alarm,

1.Press the RF calendar clock and alarm window.

2.Press [ALARM] and the 

 indicator will be display to indicate

you are in the alarm mode.

3.Press and hold [SET] till the hour digit flash.

4.Use [ 

 

] and [ 

 

] to change to the desired setting.

5.Press [SET] for minutes setting.

6.Use [ 

 

] and [ 

 

] to change to the desired setting.

7.Press [SET] to confirm.

Note:

 the window will show “

” if no alarm is armed.

Once set, the alarm clock will be activated automatically and the

alarm indicator 

 will light up. When an alarm goes off, press any

button to stop it. The alarm is still active and will go off again the
next day.

To deactivate the function,

1.Press the RF calendar clock and alarm window.

2.Press [ALARM ON/OFF]. The alarm indicator 

 will disappear.

ABOUT RADIO CONTROLLED CLOCK RECEPTION

Whenever  the 

WMR928NX

  is  brought  within  range  of  the  radio

signal with its radio reception function activated, it will search for
the clock signal at a predefined time on each day while the manual
calendar clock settings will be overridden.

While receiving the signal the radio reception indicator will blink.
A complete reception generally takes 

to 10 minutes, depending

on the strength of the radio signal.

The  indicator  will  stop  blinking  when  the  reception  is  complete.
The status of reception will be shown:

To disable the radio reception function:

1.Press the RF calendar clock and alarm window.

2.Press and hold [ 

 

] to disable the function. The radio reception

indicator  will  disappear.

To enable the function again,

1.Press the RF calendar clock and alarm window.

2.Press and hold [ 

 

] to enable the function. The radio reception

indicator  will  blink.

WEATHER FORECAST

The  weather  forecast  is  displayed  in  the  weather  forecast  and
barometric reading window.

There  are  four  readings  for  the  forecast:  sunny,  slightly  cloudy,
cloudy  and  rainy.

- Strong

- Weak

- No  signal

- Receiving

Forecast

Sunny

Slightly  Cloudy

Cloudy

Rainy

Indicator

displays  on

the  unit

Summary of Contents for WMR928NX

Page 1: ...ransmitter STR938 The WMR928NX can support up to seven different remote instruments You can also connect up to three optional thermo or thermo hygro sensors to the system Optional items include Thermo hygro sensor THGR228N THGR238N Thermo sensor THR228N THR238N Contact an authorized dealer for optional items SECTION 2 INSTALLATION The WMR928NX operates at 433MHz No wire installation is required am...

Page 2: ...the rain collector to check the leveling 5 Use metal ring to adjust the leveling of the rain collector if necessary 6 Close the cover of the rain collector THE SOLAR TRANSMITTERS The solar transmitters make use of solar energy to power the instruments they are connected to Note It is recommended to insert two UM3 or AA sized super lithium batteries for sub zero weather conditions For the solar tra...

Page 3: ...gauge baro thermo hygrometer thermo hygrometer and optional remote thermo and thermo hygro sensors Replace the batteries when the respective indicators light up Note The readings collected from the thermo hygrometer and any optional remote thermo and thermo hygro sensors share the same display window The OUT and remote channel will share the same low battery indicator When the battery level of the...

Page 4: ...flash 4 Use and to change to the desired setting 5 Press SET for minutes setting 6 Use and to change to the desired setting 7 Press SET to confirm Note the window will show if no alarm is armed Once set the alarm clock will be activated automatically and the alarm indicator will light up When an alarm goes off press any button to stop it The alarm is still active and will go off again the next day...

Page 5: ...ory is clear INDOOR HUMIDITY The current indoor relative humidity taken by the indoor baro thermo hygrometer is displayed on the indoor hygrometer window To display the maximum minimum and current humidity 1 Press the indoor humidity window 2 Press MEMORY repeatedly for the desired record The time and date of the record will also be displayed alternatively with STAMP icon in the clock window To cl...

Page 6: ...tting will be displayed OUTDOOR AND CHANNEL HUMIDITY The relative humidity readings taken by the outdoor thermo hygrometer and separate thermo hygro sensors are displayed on the outdoor channel humidity window As this window can display up to four different sets of data specify the instrument or channel you want to read To do so 1 Press the outdoor channel humidity window 2 Press CHANNEL to go fro...

Page 7: ...r receive the signal from those sensors 2 If you have disconnected signals you cannot clear the memory THE RESET BUTTON This button is only used when the system is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button The main unit will return to all default settings and start searching for signals again Before resetting the main unit you should do the same f...

Page 8: ... Scientific products such as digital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes contact information for our customer care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the i...