background image

To Set Watering Cycles:

Multiple watering cycles is simply the where the sprinkler timer 
will cycle.

Using multiple watering cycles is ideal for reducing runoff and  
standing water.  This sprinkler timer allows program A or B  
(or both) to be repeated on the days programed. 

When extra watering is needed, Program A or B (or both) can 
be set to repeat the set watering durations up to 10 times a day. 
In order to maximize absorption and prevent runoff, you may 
set a specific number of minutes or hours between the start of 
one cycle and the start of the following cycle. This is called the 
“cycle delay” and can be set from 0 minutes to 90 minutes in 
10-minute increments, and from 2 hours to 23 hours in
one-hour increments.

•  

From the HOME/AUTO screen, press 

PROG. A

q

to enter  

    the program review screen. Toggle to desired program.

•  

Press 

CYCLES

.

•  

Press 

or 

to select the desired number of watering  

    cycles.  Press 

ENTER

.

•  

Press      or    to select the desired number of minutes or   

    hours (from 0 minutes to 23 hours) between the start time of   
    one cycle and the start time of the following cycle.  
    Press 

ENTER

.

•  

Repeat this procedure for the other program, if desired.

To Change Settings From the  

HOME/AUTO Screen:

Orbit

®

 has simplified the way to make modifications to 

your timer.  Just tap the setting you want changed in the  
HOME/AUTO screen.

    

 Tap the date to change the current date

    

 Tap the time to change the time of day

    

 Tap the 

NEXT START

 to change the time of day you want  

       to water
    

 Tap the station number to modify the watering durations

    

 Tap 

PROG

 to modify the Watering Days

    

 Tap 

CYCLES

 to modify the number of watering cycles  

•  

Press the 

HOME/LOCK

 button at any time to return to the 

HOME/AUTO screen.

To Water in Manual Mode:

•  

To manually water one, some or all stations, press 

MANUAL

  

    at the top right of the HOME/AUTO screen.

•  

The first screen MANUAL - ALL will allow you to water all  

    stations with the same duration (1 to 240 minutes). Select  
    the desired duration, then press 

ENTER

•  

Or

, press 

NEXT

 for MANUAL - SELECT watering. This  

    screen allows you to select any single station or a group of  
    stations each with individual durations (1 to 240 minutes)   
    using  and      or     the Quick Touch buttons. Select the   
    desired stations and durations then press 

ENTER

.

•  

Or

, press 

NEXT

 again for MANUAL - PROG A watering. This  

07WTM004225 57932-24 rE.indd   6

5/2/07   4:39:23 PM

Summary of Contents for B-hyve 57946

Page 1: ...d not be used as the source to create final printed pieces of the file it represents Rather it is a low resolution visual reference only containing relevant information regarding the file e g color te...

Page 2: ...b no 07WTM004225 client ORBIT sku 57932 upc NA file name 07WTM004225 57932 24 rE indd software InDesign CS2 colors additional instructions color non printing PMS 280 PMS color non printing PMS Registr...

Page 3: ...d this manual completely before you begin programming and using the timer Important Features and Capabilities PC Programmable Visit www orbitonline com to download software which will allow you to pro...

Page 4: ...B is stored indefinitely in the timer s non volatile memory EEPROM and internal memory This high end feature means your programming won t be lost or erased if the power and batteries go out Convenien...

Page 5: ...ignore the rain sensor This switch is for hard wired sensors only and does not effect wireless rain sensors Section 2 Getting Started Set Language Press the RESET button The controller will now take y...

Page 6: ...ressing the station number on the bottom of the touch screen or press ENTER to advance to the desired station Note The active station being programed will Flash Set the watering duration for each stat...

Page 7: ...lowing cycle Press ENTER Repeat this procedure for the other program if desired To Change Settings From the HOME AUTO Screen Orbit has simplified the way to make modifications to your timer Just tap t...

Page 8: ...ors To change the communication status between the timer and the wireless sensor do the following Press the BUDGET button on the Home Auto Screen Press the SENSOR button on the top right of the screen...

Page 9: ...ht on the timer Press the OFF button on the remote or depress the stem of the RF sensor the red light should start blinking If the red light blinks you have successfully synchronized the devices If th...

Page 10: ...outlet Avoid using an outlet controlled by a switch In a dry indoor location where operating temperatures are not below 32 or above 122 Fahrenheit below 0 degrees or above 50 degrees Celsius Not in d...

Page 11: ...wire Taking the sprinkler wire strip 1 2 12 mm of the plastic insulation off the end of each individual wire Connect one wire from each valve it doesn t matter which wire to a single common sprinkler...

Page 12: ...f you are activating a pump from this timer you must purchase a Pump Start Relay From the pump start relay or master valve connect one wire to the PUMP terminal and the other wire to the COM terminal...

Page 13: ...lenoid 2 Test the station by operating a manual watering sequence 3 If the short is not detected after a few seconds the fault notification message will be terminated 4 If the message continues a shor...

Page 14: ...ler timer from running it s scheduled watering program for a specific duration A feature that allows a program to be operated multiple times on the same day The electrical part on a sprinkler irrigati...

Page 15: ...ram the timer Based on the preceding information your watering program may look like this A A B B Program Days of Week Days of Week Odd Even Interval Watering Option 1 2 3 4 Station M W Sat M W Sat Ev...

Page 16: ...not programmed to 1 Transformer is defective or is not connected correctly 2 Programming is incorrect 3 Timer is in OFF mode 1 Water pressure is too high 2 More than one cycle is programmed 3 Stations...

Page 17: ...or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Co...