background image

4

5

ENGLISH

Programming Buttons

These nine buttons are used for programming and other 
operations:

A

  

RF Sync (only on remote control model)  

     Allows the timer to synchronize with a new remote or wire 
     less sensor.

b

  

Rain Delay 

 

     Push this button once while in AUTO to access the rain  
     delay option. NOTE: Pressing this button will access the  
     Language and No Watering Period options while in those  
     respective dial positions.

c

  

Reset (pin hole)

  

     Resets the timer to its factory settings.

d

  

Increase

e

  

Decrease

f

  

Enter

g

  

Next

h

  

Clear

i

  

Manual

 

Selection Dial

This dial is used for programming, reviewing and operating the 
sprinkler timer.

Rain Sensor Bypass Switch

In Active position the controller will monitor the rain sensor, in 
Bypass position the controller will ignore the rain sensor. (This 
switch is for hard wired sensors only and does not effect wireless 
rain sensors - sensors sold separately).

About This Manual

We have added the following features to this manual to assist 
you:

•  

BLUE TEXT

 relates to the buttons used for programming.

•  

BLUE UNDERLINED TEXT

 relates to stop positions for the 

    selection dial.

•  

A glossary of the most common terms is included. 

    (see page 16)

Section 2: 

Getting Started

You can program this sprinkler timer in just a few basic steps. 
Before you begin programming, it is important to:

•  

Activate the batteries

•  

Reset the sprinkler timer

•  

Select the preferred language

•  

Set the time of day and date

•  

Determine a watering plan

Activating the Batteries

•  

Slide the docking port off the timer unit to gain access to the 

    battery compartment door.

•  

Slide the door off the battery compartment in the direction 

    of the arrow.

•  

Remove the black strip from the battery compartment.

•  

Replace the battery compartment door.

•  

Slide the docking port back onto the main controller unit.

The display will show “LOW BATTERY” when it is time to 
replace the batteries.

NOTE: Batteries alone will not operate the valves in your sprinkling 
system. The transformer must be plugged in and have power to oper-
ate your system normally.

Reset the Timer

If this is the first time the sprinkler timer has been pro-
grammed, you should press the small recessed button labeled 

RESET

 (located under the 

RAIN DELAY

 button). You will prob-

ably need a pen, pencil or similarly small object to push it.

Do not press the 

RESET

 button again unless you want to com-

pletely remove all your programming, including time and date.

If no programming occurs after the 

RESET

 button has been 

pressed and the dial is left in the 

AUTO

 position the timer will 

assume a default program mode. In default mode, the timer will 
automatically water each station for 10 minutes, beginning at 5 
a.m. each day.

Select the Preferred Language

  Turn the selection dial to 

BUDGETING/LANGUAGE

.

  Press the 

RAIN DELAY

 button. 

  Press the 

NEXT

  

button until the desired language is 

    shown in the display. 

  Exit the language selection mode by turning the selection dial 

    or pressing the 

RAIN DELAY

 button.

Set the Time of Day and Date

If this is the first time the timer has been programmed, press 
the small recessed 

RESET

 button.

  Turn the selection dial to 

TIME/DATE

.

  The top line of the display reads “SET TIME.” Set the current 

    time by pressing either the        or        button.

NOTE:  To move faster through the time or other selections, hold the    
       or        buttons down, rather than merely pressing and releasing.

  Press the 

ENTER

  

button. The display now reads “SET 

    YEAR.” Set the current year by pressing either the
           or        button.

RF SYNC

ACTIVE

BYPASS

NO

 W

AT

ER

IN

G

DA

Y /

 

PE

RI

OD

Figure 1: 

Front view of timer

d

e

f

g

h

i

Summary of Contents for ST2-RF

Page 1: ...ware InDesign CS3 colors additional instructions Font sizes cannot be smaller than 7 pt color non printing PMS 280 PMS color non printing PMS Registration CMYK Printers are responsible for meeting print production requirements Any changes must be approved by the client and Fluid Studio printed piece must meet designated specifications on this form dimensions flat w 13 76 h 5 7 finished w 6 88 d 0 ...

Page 2: ...nywhere to create or change watering programs Remote Control Capabilities Not included on all models This timer can be controlled by the included remote control device via a radio frequency RF receiver and antennae both of which are built into the timer The remote control device allows you to turn stations on and off on the spot and to perform programming tasks from anywhere within range The 433 m...

Page 3: ...ttery compartment Replace the battery compartment door Slide the docking port back onto the main controller unit The display will show LOW BATTERY when it is time to replace the batteries NOTE Batteries alone will not operate the valves in your sprinkling system The transformer must be plugged in and have power to oper ate your system normally Reset the Timer If this is the first time the sprinkle...

Page 4: ... flashes Press the or buttons to select the desired interval select between every 1 day and every 32 days An interval of 2 means it will water every other day You can deactivate the INTERVAL mode by pressing the CLEAR button or by selecting another watering day mode The water drop will disappear Set the Timer to Automatically Run Your Programs Turn the selection dial to AUTO The timer will be cont...

Page 5: ...Water Budgeting is a quick way to adjust your set durations 10 to 200 based on seasonal requirements Turn the selection dial to BUDGETING LANGUAGE Either press the button to increase the watering times or press the button to decrease the times in increments of 10 percent A setting of 100 will not change the set durations a setting of 200 will increase a 10 minute duration to 20 minutes and a setti...

Page 6: ... watering from the current station to the next station in the cycle This can be done during scheduled manual or remote actuated watering Section 4 Using the Remote Control Device NOTE The timer will accept commands from the remote control device only when the selection dial is turned to AUTO or OFF If the selection dial is turned to any other setting commands from the Remote Control Device will be...

Page 7: ...g tools on hand Phillips screwdriver Wire strippers Installing the Sprinkler Timer in Five Easy Steps 1 Select a Location Select a location with the following criteria Near an electrical outlet Avoid using an outlet controlled by a switch In a dry indoor location where operating temperatures are not below 32 or above 122 Fahrenheit below 0 degrees or above 50 degrees Celsius Not in direct sunlight...

Page 8: ...e against the wall aligning the two holes in the sleeve with the two drilled holes Secure the sleeve to the wall by screwing a No 8 screw included through each of the two holes Slide the remote control device into the sleeve Section 7 Diagnostics Circuit Breaker Smart Scan Diagnostic Fault Sensing A diagnostic fault sensor will automatically scan for the presence of a faulty solenoid or wiring sho...

Page 9: ...es Front Strip Front North Back North Front Location Spray Heads Spray Heads Gear Drive Shrub Head Sprinkler Grass Grass Grass Shrubs and Flowers Plants Determine a Watering Plan Your timer has two programs Program A and Program B The dual program capability allows you to assign certain water ing stations to Program A and others to Program B There are various reasons why you would want to do so Fo...

Page 10: ...ormer Push down timer on docking port until back light turns on Reduce the number of start times for that program Install pressure reducer Check wiring or replace solenoid Section 9 Trouble Shooting Help Before returning this sprinkler timer to the store contact Orbit Technical Service at 1 800 488 6156 1 801 299 5555 Listings Hereby Orbit Irrigation Products Inc declares that this conroller is in...

Page 11: ...e incluye en todos los modelos El temporizador puede controlarse mediante un control remoto que se activa por medio de una antena y un receptor de radiofrecuencia RF incorporados al temporizador El control remoto le permite encender y apagar las estaciones desde su sitio y configurar la programación desde cualquier lugar siempre dentro del alcance del dispositivo La frecuencia remota de 433 megahe...

Page 12: ...ora y la fecha Determine un plan de riego Activación de las baterías Deslice el terminal de conexión del temporizador para ac ceder a la puerta del compartimiento de las baterías Deslice la puerta del compartimiento de las baterías en la dirección de la flecha Retire la cinta negra del compartimiento de las baterías Vuelva a colocar la puerta del compartimiento de las baterías Deslice el terminal ...

Page 13: ...el otro programa Salga de la modalidad para colocar duración del riego girando la esfera de selección Establezca los días de riego Gire la esfera de selección DÍAS DE RIEGO para el programa que desee colocar A o B Establecer los intervalos de riego Presione el botón SIGUIENTE para moverse a través de los días de la semana Mo Lunes Tu Martes We Miércoles Th Jueves Fr Viernes Sa Sábado and Su Doming...

Page 14: ...mojen cuando vayan a la escuela Siga los siguientes pasos Gire la esfera de selección a DÍA PERÍODO SIN RIEGO Presione el botón RETARDO POR LLUVIA En la esfera aparecerá SIN AUGA INICIO PERÍODO Presione el botón o para establecer el inicio del período en el que no desea que se active el agua Presione el botón INGRESAR En el selector aparece SIN AUGA FIN PERÍODO Presione el botón o para establecer ...

Page 15: ...NTE para seleccionar el número de estación que desea regar Presione el botón o para seleccionar el número de minutos para regar esa estación desde 1 hasta 120 minutos Presione el botón INGRESAR Para abortar el proceso antes que el riego manual se haya termi nado presione BORRAR De otro modo el temporizador saldrá automáticamente de la modo MANUAL ESTACIÓN despues que la estación elegida se haya ac...

Page 16: ...os X minutos deseados Para regar más de una estación específica Presione los números de las estaciones que desea regar Por ejemplo 3 7 10 y 6 El temporizador regará en orden de menor a mayor 3 6 7 10 Independientemente del orden en el cual presione las teclas el temporizador las regará en orden ascendiente Presione ON X MIN para regar las estaciones durante los X de minutos deseados Para cancelar ...

Page 17: ...ndividual de color gris encajando comple tamente el cable pelado en la terminal debajo de cada número Vea la Figura 5 Conecte el cable común a una de las dos terminales de color blanco marcada con la palabra COM NOTA Inserte sólo un cable en cada receptáculo COM Si se necesita más de dos cables en común empalme varios juntos para que sólo un cable atraviese cada una de las dos terminales COM Prote...

Page 18: ...ilas continuarán activando el LCD Tras unos segundos el temporizador restaurará automáticamente el circuito para comprobar si las condiciones han desaparecido Si así es el interruptor del circuito el interruptor se restaurará a sí mismo Hora de inicio del ciclo Válvula maestra Horas de inicio múltiples Programa A o B Retardo por lluvia Solenoide Temporizador del aspersor Apilamiento Estación Estac...

Page 19: ...riego de los canteros todos los días y utilizar el Programa B para regar el césped cada segundo o tercer día Su temporizador le permite establecer hasta seis horas de inicio diferentes para los ciclos de riego en el Programa A o en el B No puede establecer una hora de inicio de ciclo para cada estación Las estaciones pueden asignarse bien al Programa A o al B Las estaciones asignadas a un programa...

Page 20: ...esactiva Síntoma Posible causa del problema Ninguna de las estaciones se activa 1 Solenoide defectuoso 2 Cable roto o no está conectado 3 Vástago de control de flujo hacia abajo cerrando la válvula 4 La programación es incorrecta 1 Válvula defectuosa 2 Partículas de sucio o desechos atascados en la válvula 3 Diafragma de la válvula defectuoso El temporizador no responde Las estaciones continúan ac...