background image

10

11

ENGLISH

Manual Watering - Program B:

This will allow you to water only those stations with set dura-
tions in Program B. 

  With the dial in the 

AUTO

 position press the 

MANUAL

  

     

    button. 

  Press the 

NEXT

 

button until the display reads “B  

    MANUAL ALL”.

  Press the 

ENTER

 

button.

Each station will water, in sequence, one after another, for the 
same duration specified in Program B. To quickly advance from 
one station to the next press 

NEXT

         .

To abort this process before the manual watering is finished, 
tpress 

CLEAR

       

. Otherwise, the timer will automatically 

exit the “B – MANUAL ALL” mode after all Program B stations 
have run. 

Manual Watering - Single Stations:

This will allow you to water a single station at a time.

  With the dial in the 

AUTO

 position press the 

MANUAL

  

     

    button. 

  Press the 

NEXT

 

button until the display reads     

    “MANUAL STATION 1”.

  Press the 

NEXT

 

button to select the station number  

    you want to water.

  Press the 

or 

buttons to select the number of min- 

    utes to water that station (from 1 to 120 minutes).

  Press the 

ENTER

 

button.

To abort this process before the manual watering is finished, 
press 

CLEAR

       

. Otherwise, the timer will automatically exit 

the “MANUAL – STATION” mode after the selected station has 
run.

Rain Delay Function:

You can press the 

RAIN DELAY

 button to stop all programmed 

watering from taking place for a certain number of hours or 
days (for instance, after a rain storm).

  With the dial in the 

AUTO

 position press the 

RAIN DELAY

  

    button. 

  Press the 

or 

buttons to change the rain delay 

    period. The options are: 24 hours, 48 hours, 72 hours, 4 
    days, 5 days … and up to 99 days in one-day increments.

  Press the

 ENTER

 

button to enter the rain delay mode.  

    The Rain Delay hours remaining will show on the display.

The timer will revert to the programmed schedule at the expira-
tion of the rain delay period. To return to the programmed 
schedule before the expiration of the rain delay period, press 
the 

CLEAR

 

button.

Manual Advance During Watering:

  Pressing the 

NEXT

 

button will advance watering from  

    the current station to the next station in the cycle. This can  
    be done during scheduled, manual, or remote actuated  
    watering.

Section 4: 

Using the Remote 

Control Device

NOTE: The timer will accept commands from the remote control 
device only when the selection dial is turned to 

AUTO

 or 

OFF

. (If 

the selection dial is turned to any other setting, commands from the 
Remote Control Device will be stored in memory and executed when 
the selection dial is turned to 

AUTO

).

Install a Battery in the Remote Control Device:

•  

Open the battery compartment door. 

•  

Install a 9-volt battery in the battery compartment. 

•  

Replace the battery compartment door.

To Synchronize the Remote Control Device 
with the Timer:

The remote device provided with your timer is already synchro-
nized to your timer. If the remote is not functioning properly or 
if you are adding a new remote or RF sensor to your system do 
the following:

•  

With the remote device in your hand press the “

RF Sync

”  

    button on the timer (this will activate a red light on  
    the timer). 

•  

Press the 

OFF

 button on the remote or depress the stem of  

    the RF sensor (the red light should start blinking). 

•  

If the red light blinks you have successfully synchronized the  

    devices. If the light does not blink check that the remote has a  
    fresh 9V battery or that the RF sensor switch is not OFF and  
    try the steps again.

To Water All Stations:

•  

Press and release the 

ALL 

button on the remote control  

    device to select all stations for watering.

•  

Press and release the 

ON “X” MIN

 button to command the  

    timer to water all the stations sequentially for the desired  
    (“X”) number of minutes.

•  

If you wish to advance to the next station before a station's  

    watering duration is complete, press 

NEXT

.

To Water One Station:

•  

Press the number of the station you wish to water. 

•  

Press 

ON "X" MIN 

to water the station for the desired ("X")  

    number of minutes.

 
To Water More Than One Specific Station:

•  

Press the numbers of the stations you wish to water. (Example:  

    3, 7, 10, and 6. The timer will water in sequence from lowest  
    to the highest. 3, 6, 7, 10.) (No matter which order you press  
    the keys, the timer will water them sequentially from the  
    lowest to the highest number.)

C

C

C

Summary of Contents for ST2-RF

Page 1: ...ware InDesign CS3 colors additional instructions Font sizes cannot be smaller than 7 pt color non printing PMS 280 PMS color non printing PMS Registration CMYK Printers are responsible for meeting print production requirements Any changes must be approved by the client and Fluid Studio printed piece must meet designated specifications on this form dimensions flat w 13 76 h 5 7 finished w 6 88 d 0 ...

Page 2: ...nywhere to create or change watering programs Remote Control Capabilities Not included on all models This timer can be controlled by the included remote control device via a radio frequency RF receiver and antennae both of which are built into the timer The remote control device allows you to turn stations on and off on the spot and to perform programming tasks from anywhere within range The 433 m...

Page 3: ...ttery compartment Replace the battery compartment door Slide the docking port back onto the main controller unit The display will show LOW BATTERY when it is time to replace the batteries NOTE Batteries alone will not operate the valves in your sprinkling system The transformer must be plugged in and have power to oper ate your system normally Reset the Timer If this is the first time the sprinkle...

Page 4: ... flashes Press the or buttons to select the desired interval select between every 1 day and every 32 days An interval of 2 means it will water every other day You can deactivate the INTERVAL mode by pressing the CLEAR button or by selecting another watering day mode The water drop will disappear Set the Timer to Automatically Run Your Programs Turn the selection dial to AUTO The timer will be cont...

Page 5: ...Water Budgeting is a quick way to adjust your set durations 10 to 200 based on seasonal requirements Turn the selection dial to BUDGETING LANGUAGE Either press the button to increase the watering times or press the button to decrease the times in increments of 10 percent A setting of 100 will not change the set durations a setting of 200 will increase a 10 minute duration to 20 minutes and a setti...

Page 6: ... watering from the current station to the next station in the cycle This can be done during scheduled manual or remote actuated watering Section 4 Using the Remote Control Device NOTE The timer will accept commands from the remote control device only when the selection dial is turned to AUTO or OFF If the selection dial is turned to any other setting commands from the Remote Control Device will be...

Page 7: ...g tools on hand Phillips screwdriver Wire strippers Installing the Sprinkler Timer in Five Easy Steps 1 Select a Location Select a location with the following criteria Near an electrical outlet Avoid using an outlet controlled by a switch In a dry indoor location where operating temperatures are not below 32 or above 122 Fahrenheit below 0 degrees or above 50 degrees Celsius Not in direct sunlight...

Page 8: ...e against the wall aligning the two holes in the sleeve with the two drilled holes Secure the sleeve to the wall by screwing a No 8 screw included through each of the two holes Slide the remote control device into the sleeve Section 7 Diagnostics Circuit Breaker Smart Scan Diagnostic Fault Sensing A diagnostic fault sensor will automatically scan for the presence of a faulty solenoid or wiring sho...

Page 9: ...es Front Strip Front North Back North Front Location Spray Heads Spray Heads Gear Drive Shrub Head Sprinkler Grass Grass Grass Shrubs and Flowers Plants Determine a Watering Plan Your timer has two programs Program A and Program B The dual program capability allows you to assign certain water ing stations to Program A and others to Program B There are various reasons why you would want to do so Fo...

Page 10: ...ormer Push down timer on docking port until back light turns on Reduce the number of start times for that program Install pressure reducer Check wiring or replace solenoid Section 9 Trouble Shooting Help Before returning this sprinkler timer to the store contact Orbit Technical Service at 1 800 488 6156 1 801 299 5555 Listings Hereby Orbit Irrigation Products Inc declares that this conroller is in...

Page 11: ...e incluye en todos los modelos El temporizador puede controlarse mediante un control remoto que se activa por medio de una antena y un receptor de radiofrecuencia RF incorporados al temporizador El control remoto le permite encender y apagar las estaciones desde su sitio y configurar la programación desde cualquier lugar siempre dentro del alcance del dispositivo La frecuencia remota de 433 megahe...

Page 12: ...ora y la fecha Determine un plan de riego Activación de las baterías Deslice el terminal de conexión del temporizador para ac ceder a la puerta del compartimiento de las baterías Deslice la puerta del compartimiento de las baterías en la dirección de la flecha Retire la cinta negra del compartimiento de las baterías Vuelva a colocar la puerta del compartimiento de las baterías Deslice el terminal ...

Page 13: ...el otro programa Salga de la modalidad para colocar duración del riego girando la esfera de selección Establezca los días de riego Gire la esfera de selección DÍAS DE RIEGO para el programa que desee colocar A o B Establecer los intervalos de riego Presione el botón SIGUIENTE para moverse a través de los días de la semana Mo Lunes Tu Martes We Miércoles Th Jueves Fr Viernes Sa Sábado and Su Doming...

Page 14: ...mojen cuando vayan a la escuela Siga los siguientes pasos Gire la esfera de selección a DÍA PERÍODO SIN RIEGO Presione el botón RETARDO POR LLUVIA En la esfera aparecerá SIN AUGA INICIO PERÍODO Presione el botón o para establecer el inicio del período en el que no desea que se active el agua Presione el botón INGRESAR En el selector aparece SIN AUGA FIN PERÍODO Presione el botón o para establecer ...

Page 15: ...NTE para seleccionar el número de estación que desea regar Presione el botón o para seleccionar el número de minutos para regar esa estación desde 1 hasta 120 minutos Presione el botón INGRESAR Para abortar el proceso antes que el riego manual se haya termi nado presione BORRAR De otro modo el temporizador saldrá automáticamente de la modo MANUAL ESTACIÓN despues que la estación elegida se haya ac...

Page 16: ...os X minutos deseados Para regar más de una estación específica Presione los números de las estaciones que desea regar Por ejemplo 3 7 10 y 6 El temporizador regará en orden de menor a mayor 3 6 7 10 Independientemente del orden en el cual presione las teclas el temporizador las regará en orden ascendiente Presione ON X MIN para regar las estaciones durante los X de minutos deseados Para cancelar ...

Page 17: ...ndividual de color gris encajando comple tamente el cable pelado en la terminal debajo de cada número Vea la Figura 5 Conecte el cable común a una de las dos terminales de color blanco marcada con la palabra COM NOTA Inserte sólo un cable en cada receptáculo COM Si se necesita más de dos cables en común empalme varios juntos para que sólo un cable atraviese cada una de las dos terminales COM Prote...

Page 18: ...ilas continuarán activando el LCD Tras unos segundos el temporizador restaurará automáticamente el circuito para comprobar si las condiciones han desaparecido Si así es el interruptor del circuito el interruptor se restaurará a sí mismo Hora de inicio del ciclo Válvula maestra Horas de inicio múltiples Programa A o B Retardo por lluvia Solenoide Temporizador del aspersor Apilamiento Estación Estac...

Page 19: ...riego de los canteros todos los días y utilizar el Programa B para regar el césped cada segundo o tercer día Su temporizador le permite establecer hasta seis horas de inicio diferentes para los ciclos de riego en el Programa A o en el B No puede establecer una hora de inicio de ciclo para cada estación Las estaciones pueden asignarse bien al Programa A o al B Las estaciones asignadas a un programa...

Page 20: ...esactiva Síntoma Posible causa del problema Ninguna de las estaciones se activa 1 Solenoide defectuoso 2 Cable roto o no está conectado 3 Vástago de control de flujo hacia abajo cerrando la válvula 4 La programación es incorrecta 1 Válvula defectuosa 2 Partículas de sucio o desechos atascados en la válvula 3 Diafragma de la válvula defectuoso El temporizador no responde Las estaciones continúan ac...

Reviews: