Table of comparation levels
Input
Type of
input
Maximum input
voltage
(Level A, C)
Maximum comparation levels
L > H
H > L
Input A
Resetting
(< 30 V)
NPN, Contact
xxx
0,5 V
4,5 V
PNP
9,7 V
0,5 V
4,5 V
PNP
14,4 V
1,0 V
9,0 V
PNP
19,2 V
1,5 V
13,3 V
PNP
23,9 V
2,0 V
17,8 V
PNP
28,7 V
2,5 V
22,1 V
PNP
33,5 V
3,0 V
26,6 V
PNP
38,3 V
3,4 V
31,0 V
PNP
43,0 V
3,9 V
35,5 V
Input A
Resetting
(< 300 V)
NPN, Contact
!!! prohibited !!!
PNP
84 V
4,9 V
39,8 V
PNP
128 V
9,2 V
78,0 V
PNP
170 V
13,6 V
117,8 V
PNP
211 V
17,8 V
156,0 V
PNP
253 V
22,3 V
195,8 V
PNP
295 V
26,5 V
234,1 V
PNP
301 V
30,9 V
273,9 V