6.3 Installation instructions
Every fireplace with a water heat exchanger
must be equipped with a
return flow boost
.
This device prevents cold return water from
cooling the firing chamber to the dew point
range (formation of condensation!).
Performance-impairing tar and soot depo
-
sits on the heating surfaces are therefore
avoided.
We recommend using the AQUAload storage
charging station which, in addition to a power-
ful circulating pump, also contains a fully pre-
configured return flow boost valve.
The set temperature is 55°C (see also the con-
nection diagram on the next page).
Installation instructions and connection infor-
mation can be found in the manual accompa-
nying
AQUAload
!
To control the circulating pump and for the ef-
ficient comparison of the temperature in the
buffer store with the heat exchanger on the
fireplace, we recommend using the
AQUA-
control III difference regulator
.
AQUAcontrol III
switches the circulating
pump on at the programmable target tempera-
ture (recommended: 60°C) and uses a second
sensor to compare the temperature in the buf-
fer store (see also the connection diagram on
the next page) with the temperature in the heat
exchanger.
Installation instructions and programming
steps can be found in the manual accompany-
ing
AQUAcontrol III
!
Difference regulator
AQUAcontrol III
.
AQUAload
with...
...and without
cover!