background image

 

Original Publication Date: 

Nov 1, 2019 

 

 

 

Oracle Talari T5200 

Hardware Guide 

Summary of Contents for Talari T5200

Page 1: ...Original Publication Date Nov 1 2019 Oracle Talari T5200 Hardware Guide ...

Page 2: ...rams No other rights are granted to the U S Government This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including applications that may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible...

Page 3: ...e Specifications 10 Installing the Talari Appliance 11 Rack Installation 11 Installing the Rack Mount Brackets and Rails 11 Separate the Inner and Outer Rails 11 Attaching Inner Rails 14 Attaching Outer Rails to the Rack 15 Adding Your T5200 to the Rack 16 LAN WAN Connections 16 Connecting Power to the Appliance 17 Important Note about Cabling and Bypass Mode 17 Powering Up the Appliance 18 Checkl...

Page 4: ...ou are connected to a live agent who can assist you with My Oracle Support registration and opening a support ticket My Oracle Support is available 24 hours a day 7 days a week 365 days a year Emergency Response In the event of a critical service situation emergency response is offered by the Customer Access Support CAS main number at 1 800 223 1711 toll free in the US or call the Oracle Support h...

Page 5: ... which can be downloaded at http www adobe com 1 Access the Oracle Help Center site at http docs oracle com 2 Click Industries 3 Click the Oracle Communications link Under the SD WAN header select a product 4 Select the Release Number A list of the entire documentation set for the selected product and release appears 5 To download a file to your location right click the PDF link select Save target...

Page 6: ...4 ...

Page 7: ... in a standard 19 inch 480mm four post rack Software The Talari Adaptive Private Networking APN Software which comes pre installed on all Talari Appliances supports current versions of the following Web browsers with cookies and JavaScript enabled Microsoft IE9 IE11 Mozilla Firefox Google Chrome Display A minimum screen resolution of 1024 x 960 or greater is recommended 5 ...

Page 8: ...rating expenses and provides greater reliability than any existing single provider WAN Using our patented Adaptive Private Networking APN technology Talari s solution combines disparate abundant affordable IP bandwidth sources and provides reliable resilient high quality connectivity between sites ensuring application and business continuity Oracle Talari Appliances deployed at headquarters and re...

Page 9: ...ne auxiliary port limited to 100 Mbps full duplex One dual hot swappable AC power supply Four multi mode fiber 10 Gigabit Ethernet ports SFP with bypass Four copper Gigabit Ethernet ports with bypass Note Running the T5200 with a single power supply is not recommended for standard operation Connect power to both power supplies when installing this device Figure 2 T5200 Rear Panel Configuration 7 ...

Page 10: ... 4 Multi mode Fiber 10 Gigabit SFP User defined forms a Bypass pair with Port 3 5 Copper Gigabit User defined forms a Bypass pair with Port 6 6 Copper Gigabit User defined forms a Bypass pair with Port 5 7 Copper Gigabit User defined forms a Bypass pair with Port 8 8 Copper Gigabit User defined forms a Bypass pair with Port 7 AUX Copper Gigabit 100 Mbps User defined used for MGT AUX May be used as...

Page 11: ...ypass pair ports 5 and 6 create a LAN WAN bypass pair and ports 7 and 8 create a LAN WAN bypass pair Figure 6 LAN WAN Ports and Bypass Pairs The aforementioned port pairs can operate in bypass mode This bypass capability allows the Talari Appliance to forward Ethernet frames between the bypass port pairs in the event of power loss or if the Talari Service is disabled The T5200 ships with the assig...

Page 12: ...y isolated from the rest of the network with the exception of the Talari WAN s own AES encrypted paths Hardware Specifications The T5200 has the following hardware specifications Specification Power 100 240 volts 50 60 Hz 9 3 5 Amp Redundant 740W ATX AC power supply UL approved FCC compliant Physical Dimensions EIA RS 310 standards 2U 437mm W x 648mm D x 89mm H 17 2 x 25 5 x 3 5 Mounting Options R...

Page 13: ...m the bottom up Load the heaviest component in the rack first Ensure that the rack is level and stable before removing components Do not move racks by yourself At least two people are required to safely move racks and stage equipment Ensure that cables are easily identifiable Installing the Rack Mount Brackets and Rails The T5200 ships with a rack mounting kit included This appliance requires a fo...

Page 14: ...Oracle Talari T5200 Hardware Guide Figure 7 Rail Assembly 1 2 ...

Page 15: ...n Figure 8 1 Separate the inner rail extension from the outer rail assembly Oracle Talari T5200 Hardware Guide 2 Extend the rail assembly by pulling it outward Figure 8 Extend Rail Assembly Figure 9 Separate Inner Rail Extension from Outer Rail 1 3 ...

Page 16: ...r rail to each side of the appliance by aligning the holes in the bracket with the corresponding hooks on the appliance 2 Slide the rails into place on the appliance 3 Secure the inner rail to the appliance using the screws provided Figure 10 Secure Rails to the Appliance 1 4 ...

Page 17: ...e smaller outer rail as illustrated in Figure 11 steps 1 and 2 6 Secure the front end of the outer rail to the rack by hanging the hooks of the rails to the rack holes and securing with screws as illustrated in Figure 11 step 3 Figure 11 Attach Outer Rails to the Rack Note The T5200 s outer rails require a minimum of 27 inches for rack installation The outer rails extend from 27 inches to 36 4 inc...

Page 18: ...locked position 4 Optional Use the screws included in the mounting kit to secure the front of the chassis to the rack Figure 13 Slide Appliance Chassis into Rack Using Installed Rails LAN WAN Connections When connecting each Ethernet LAN or WAN cable to the appropriate connector on the T5200 Position the cables carefully so that they do not put strain on the connectors Organize cables in bundles s...

Page 19: ...en your Oracle Talari Appliance is operating in bypass mode e g when it is powered off the appliance acts like a crossover cable This may cause a loss of the link between the appliance and older network devices that do not support Auto MDI X when straight through cables are used to connect the LAN and WAN ports of the appliance In such a case a crossover cable is required from the Oracle Talari Ap...

Page 20: ...ngsection of this document Configuring the Talari Appliance The T5200 ships with a default management IP address of 192 168 0 2 30 In order to access your appliance remotely you must first connect to it directly via the Management Auxiliary interface AUX and configure a management IP address for the appliance Figure 15 Configuring the Appliance Use an Ethernet cable to connect from a PC to the int...

Page 21: ...e Cannot access the Talari Web Console Confirm that you are using the correct IP address Confirm that the management port of the T5200 is connected to a switch and there is activity LEDs do not turn on Check the AC power source Check the appliance s On Off buttons Table 3 Troubleshooting Basics Troubleshooting Bypass Mode Fail to Wire The T5200 is equipped with a capability known as bypass mode or...

Page 22: ... traffic Verify that the T5200 has connectivity to the L2 L3 devices on its LAN WAN ports Verify that the correct cables are used and that the networking devices have auto negotiate set for their ports T5200 stays in bypass mode Confirm that the T5200 Appliance is configured properly and that the Talari Service is enabled Table 4 Troubleshooting Bypass Mode 2 0 ...

Page 23: ......

Reviews: