![Oracle SPARC Enterprise M4000 Installation Manual Download Page 69](http://html1.mh-extra.com/html/oracle/sparc-enterprise-m4000/sparc-enterprise-m4000_installation-manual_1646122069.webp)
Appendix B
Fault Isolation
B-11
B.3.2
Using the
prtdiag
Command
The
prtdiag
command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The
prtdiag
command is located in the
/usr/platform/
platform-name
/sbin/
directory.
Note –
The
prtdiag
command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
B.3.2.1
Options
TABLE B-4
describes options for the
prtdiag
command and how those options can
help troubleshooting.
TABLE B-4
Options for
prtdiag
Option
Description
How It Can Help
No option
Lists components.
Identifies CPU timing and PCI cards installed.
-v
Verbose mode. Displays the
time of the most recent AC
power failure and the most
recent hardware fatal error
information.
Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.
Summary of Contents for SPARC Enterprise M4000
Page 4: ......
Page 8: ...viii SPARC Enterprise M4000 M5000 Servers Installation Guide February 2012 ...
Page 14: ...xiv SPARC Enterprise M4000 M5000 Servers Installation Guide February 2012 ...
Page 26: ...2 10 SPARC Enterprise M4000 M5000 Servers Installation Guide February 2012 ...
Page 58: ...A 14 SPARC Enterprise M4000 M5000 Servers Installation Guide February 2012 ...