B-6
SPARC Enterprise M4000/M5000 Servers Installation Guide • February 2012
B.2.3
Using the
showstatus
Command
The
showstatus
displays the information concerning the server’s degraded FRUs.
An asterisk (*) which indicates that the unit has been degraded is displayed along
with any of the following states:
■
Normal
■
Faulted
■
Degraded
■
Deconfigured
■
Maintenance
An example of the
showstatus
output.
B.2.4
Using the
fmdump
Command
The
fmdump
command can be used to display the contents of any log files associated
with the Oracle Solaris fault manager.
This example assumes there is only one fault.
B.2.4.1
fmdump -V
Command
You can obtain more detail by using the
-V
option, as shown in the following
example.
XSCF>
showstatus
FANBP_C Status:Normal;
* FAN_A#0 Status:Faulted;
XSCF>
#
fmdump
TIME UUID SUNW-MSG-ID
Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
#
fmdump -V -u
0ee65618-2218-4997-c0dc-b5c410ed8ec2
TIME UUID SUNW-MSG-ID
Nov 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2
SUN4-8000-0Y
100% fault.io.fire.asic
FRU: hc://product-id=SUNW,A70/motherboard=0
rsrc: hc:///motherboard=0/hostbridge=0/pciexrc=0
Summary of Contents for SPARC Enterprise M4000