Utility-Related Issues
■
MegaMontiorSrv
After you have stopped these services, you can perform HBA card hotplug operations. You can
restart the MSM software services after the hotplug operations are complete.
Cannot Assign a Global Hot Spare Through the
MSM GUI
Bug 15762780
Issue:
From the MegaRAID Storage Manager (MSM) graphical user interface (GUI), after
creating a drive using 2 hard disks, the option to create a global host spare from a third hard
drive becomes inactive.
Workaround:
Assigning global hot spares is not supported through the MSM GUI. Instead, use
the
SAS2IRCU
utility to assign global hot spares.
Cannot Upgrade Firmware on the HBA Therough
the MSM GUI
Bug 15664024
Issue:
The firmware level on the HBA remains the same after using the MegaRAID Storage
Manager software to upgrade the firmware.
Workaround:
Upgrading firmware through the MegaRAID Storage Manager software is not
supported for this HBA. To upgrade firmware on the HBA, use the
SAS2IRCU
utility. You can
obtain the
SAS2IRCU
utility from the Oracle support area of the LSI web site:
http://www.lsi.com/sep/Pages/oracle/index.aspx
Utility-Related Issues
This section contains the following information:
■
“Sun Storage 6 Gb SAS PCIe HBA, Internal is Not Displayed in the BIOS Setup
■
“A Hard Drive is Not Displayed in the BIOS Setup Utility” on page 63
■
“Non-Alphabetical Characters Are Displayed in RAID Volume Names” on page 63