Connect the Chassis Ground Wire
Related Information
■
“Preparing for Installation” on page 27
■
“Installing the Server” on page 31
■
“Connecting Cables” on page 61
Connect the Chassis Ground Wire
The server shipping kit contains a grounding lug for connecting a chassis grounding wire to the
rear of the server. You must supply the grounding wire.
Caution -
The DC power source must be reliably grounded. The server chassis must be
grounded with the power supply ground pins or with the chassis ground studs. It is acceptable to
have both grounds connected.
This procedure is optional for servers with AC input power, however, it is highly recommended.
For AC input power, it is acceptable to ground the server through the supplies and chassis
ground wire.
1.
Retrieve the grounding lug and two M5 nuts from the shipping kit.
2.
Insert the grounding wire into the barrel receptacle of the grounding lug, and use
a crimping tool or solder gun to secure the wire.
3.
Go to the back of the server and locate the two grounding studs.
72
Netra SPARC S7-2 Server Installation Guide • January 2017
Summary of Contents for Netra SPARC S7-2
Page 1: ...Netra SPARC S7 2 Server Installation Guide Part No E73206 03 January 2017 ...
Page 2: ......
Page 8: ...8 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Page 10: ...10 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Page 26: ...26 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Page 60: ...60 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Page 96: ...96 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Page 102: ...102 Netra SPARC S7 2 Server Installation Guide January 2017 ...