Operation
33
-
Furthermore, the amount of glass produced can be displayed in the
software. In this way, it is possible to see how much glass has been
produced in a linescan pass. This information can be found in the digital
display group.
Figure 14:
Digital display
group
Another component of the system is the control unit. With this unit the
shutters can be opened and closed again. During the first installation it is
necessary to align the devices. This can only be done when the shutters are
open.
When the system is powered, the yellow LED is on and the shutters are
closed. When the button is pressed, the shutters are opened and the LED
turns off.
The green button is for measuring low-E glass. It is deactivated at first use.
When activated, the temperature range is changed from 150-900 °C to
0-250 °C.
Figure 15:
Control unit