Use clean hands when handling a respirator.
1

. Remove packaging and open the respirator and take hold of the head straps.

2

. Hold the respirator over your nose, mouth and chin, lightly secure on the face with   

  one  hand on the outside, and with your free hand pull the two retaining straps over 
      your head. Do not touch the respirator on the inside.

3

. Pull the lower retaining strap under your ears and pull the upper retaining strap 

  over the back of your head.

4

. Press the nose clip onto your face with both index fingers. 

     Spectacle wearers: remove the spectacle to adjust the nose clip! 
  Pinching the nose clip using one hand may result in improper fit and less
      effective respirator performance. Use two hands.

5

. Perform a User Seal Check prior to each wearing. To check the respirator-

     to-face seal, place both hands completely over the respirator and exhale
     sharply. Be careful not to disturb the position of the respirator. If air leaks 
     around nose, readjust the nosepiece as described in step 4.

      

If you CANNOT achieve a proper seal, DO NOT enter the contaminated

       area. Report to your supervisor.

Fitting - and Removal Instructions

Removal Instructions

:

Spectacle wearers: remove glasses before removing the respirator.
Hold the retaining straps with both hands, pull over your head and remove the respirator from 
your face. Remove the respirator without touching the respirator components. Wash and 
clean your hands after removing the respirator. Dispose of used product in accordance with 
applicable regulations

.

 

Single use only! Do not reuse! 

Storage Conditions and Shelf Life (Details see last page)

Before use, store respirators in the original packaging away from 
contaminated areas, dust, sunlight, extreme temperatures, excessive 
moisture and damaging chemicals.
When stored in accordance with temperature and humidity conditions 
specified below, the product may be used until the "use by" date 
specified on packaging. Always inspect product and conduct a user 
seal check before use as specified in the 

User Instructions

.  

If you 

cannot achieve a proper seal, do not use the respirator

.

Time Use Limitation

If respirator becomes damaged, soiled or breathing becomes difficult 
(e.g. saturated with breathing air humidity), leave the contaminated 
area immediately and replace the respirator.

The respirator is intended for single use and cannot be reused

.

Acceptable Fit Test Protocols

 

Fit Test Protocol*
Qualitative Protocols         Saccharin        Acceptable with this product!
                                                      Bitrex TM          Acceptable with this product!
Quantitative Protocols*                                     Acceptable with this product!
*Refer to OSHA 1910.134.