NEBULIZZATORE MESH

MESH NEBULIZER

NÉBULISEUR MESH

MESH-INHALATOR 

NEBULIZADOR MESH 

NEBULIZADOR MESH

M28066-M-Rev

.0-01.20

PROFESSIONAL MEDICAL PRODUCTS

CONTEC MEDICAL SYSTEMS CO., LTD

No.112 Qinhuang West Street,

Economic & Technical Development Zone, Qinhuangdao,

Hebei Province, PEOPLE’S REPUBLIC OF CHINA

Made in China

28066 / NE-M01

ATTENZIONE: 

Gli operatori devono leggere e capire 

completamente questo manuale prima di utilizzare il prodotto.

ATTENTION: 

The operators must carefully read and completely 

understand the present manual before using the product.

AVIS: 

Les opérateurs doivent lire et bien comprendre 

ce manuel avant d’utiliser le produit.

ACHTUNG

: Die Bediener müssen vorher dieses Handbuch 

gelesen und verstanden haben, bevor sie das Produkt benutzen.

ATENCIÓN: 

Los operadores tienen que leer y entender 

completamente este manual antes de utilizar el producto.

ATENÇÃO: 

Os operadores devem ler e entender 

completamente este manual antes de usar o produto.

Manuale d’uso - User manual 
Manuel de l’utilisateur - Gebrauchsanweisung 
Guía de Uso - Guia para utilização

%

96%

5%

IP22

55°C

-40°C

Shanghai International Holding Corp. GmbH (Europe)

Eiffestrasse 80, 20537, Hamburg, Germany

0123

1060 hPa

500 hPa

Summary of Contents for 28066

Page 1: ...TTENTION The operators must carefully read and completely understand the present manual before using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produ...

Page 2: ...thetic mixture Otherwise it may cause personal injury Do not wrap the power cord around children s neck or other sensitive areas or it may cause asphyxia The mask of this equipment is made of PVC mate...

Page 3: ...batteries is DC3V 2 3 Operational environment Temperature 5 C 40 C Humidity 15 90 Atmospheric pressure 700hPa 1060hPa Attention This product is not suitable for use in strong electromagnetic interfer...

Page 4: ...cup to the main unit be sure to install it properly until clasp sound is heard Otherwise it may cause electrode conduction failure then the device cannot atomize normally 2 Remove medication cup from...

Page 5: ...ery life will be affected Remove the batteries if the device won t be used for long time 4 2 Operations for treatment use Preparations before use 1 Remove medication cup please clean and disin fect it...

Page 6: ...the cup lid and discard residual medication 3 Add 75 ethanol solution in medication cup cover the cup lid then leave for at least 10mins it is advisable to gently shake it for better disinfection 4 Im...

Page 7: ...medication cup Trickle medication into medication cup re member not to exceed its maximum capacity Improper medication Consult a doctor about whether the medica tion is suitable for the device The ne...

Page 8: ...ode Keep away from sunlight 55 C 40 C Store between 40 and 55 C Lot number Fragile handle with care Date of manufacture Serial number Follow instructions for use Medical Device complies with Directive...

Page 9: ...4 2 Air Discharge 2 kV 4 kV 8 kV 15 kV contact 8 kV air Air Discharge 2 kV 4kV 8 kV 15 kV contact 8 kV air Floors should be wood concrete or ce ramic tile If floor is covered with synthetic material...

Page 10: ...ct was purchased If the equipment is not disposed of correctly fines or penalties may be applied in accordance with the national legislation and regulations GIMA WARRANTY CONDITIONS Congratulations fo...