11) Analog output
The device has an analog output for each tem-
perature channel. Prior to shipment, the fiber
optical thermometer is factory set to one of
the following configurations: 4-20mA or 0-10V.
The analog output is located on the back panel
below the ST socket as BNC type. The limits are
set to 0°C and 300°C. The temperatures corres-
pond to values between 4-20mA or 0-10V. If no
temperature sensor is connected, the maximum
value is considered.