Figure 1-21
Set Frequency Converter Control
7.5.5 View Trigger Line Rate
⚫
Trigger Line Rate: It relates to the external trigger raw line rate after filtering, and it only
involves external trigger signals.
⚫
Resulting Trigger Line Rate: It relates to the external trigger frequency cameras received
after the external trigger raw line rate is calculated via frequency converter control. It
only involves external trigger signals.
You need to select external trigger sources as
Input Source
to display specific values in
Trigger Line
Rate
and
Resulting Trigger Line Rate
. If
N/A
is selected as
Input Source
,
these two parameter values will be 0.
Figure 1-22
View Trigger Line Rate
Make sure that line trigger is enabled and input source value of frequency converter control and