V 1.0 - eng
27
COE LS-X Line Scan Camera | USER MANUAL
Figure 1-15
Function Demonstration
The advantages of shaft encoder are as follows:
⚫
Encoder output pulse frequency is proportional to rotating speed.
⚫
The output pulse acts as a trigger signal for line scan camera.
⚫
Synchronize acquisition speed and sample movement of camera.
⚫
Non-uniform motion can also be a perfect match.
⚫
A trigger signal can be set as acquiring multiple lines or multiple frames with adjustable ratio.
Follow steps below to set shaft encoder control.
Steps:
1. Click
Encoder Control
, and set
Encoder Source A
and
Encoder Source B
according to
actual demands.
2. Set
Encoder Trigger Mode
.
⚫
Any Direction
means that both forward and backward direction will trigger.
⚫
Forward Only
mean that only forward direction will trigger.
⚫
Backward Only
mean that only backward direction will trigger.
The COE LS-X cameras output four signal in one source signal.
3. You can set
Encoder Trigger Frequency
to let the camera output multiple signals, including 1
Tick, 2 Tick and 4 Ticks.
Figure 1-16
Process Logic of 1 Tick