DVR Server Manual ver.5.05/rel.092507
21
【
Record Begin Disk
】
Select the first disk from which the DVR system saves data. The
prior disks before the selected drive will not be used to store video files and it will not be checked by
the system. When the capacity of HDD is not enough or there are some mistakes while recording,
system will inform the failure of recording and the corresponding camera will stop recording.
【
Alarm camera popup interval
】
Set the interval of alarm camera, if you select‖—―,you
can‘t select function
‖Start alarm popup‖.
【
DI/DO Device
】
Select receive alarm device type. When you change the type of alarm
device, you should reboot the system to update the device information in
DI/DO control panel
.
Note: Currently, system support following NV serials DI/DO devices: NV7608, NV7609, NV7616, NV7616B,
NV7632 and NV7632B. NV7632 includes two NV7616 (or combination of NV 7608 and NV 7616), and
NV7632B includes two NV7616B. When you select these two selections you must set their decoder address as
1 and 2, and they should connect with PC through RS 485 converter after they connect parallel with each other.
【
Date Mode
】
Select the way to display the date. It assigns the date display mode of the
DVR system, including the information panel on the main screen, the date panel of the playback
window and OSD date in video
.
【
Alarm Beep
】
Select disable or enable from drop-down list. If you select
―enable‖, when
there is an alarm, system will make beep sound.
【
Time Mode
】
Select time format from the drop-list. After you change the format it will
affect the OSD format, information in information display panel and file lists.
【
Default Camera type
】
Set the default mode of video from PAL and NTSC. It is available
when the input video is lost and for the decoder to playback local video to TV Wall.
2.1.2 Network setup
【
Remote Connection
】
Select to allow remote connection or not.
If you select
―disable‖, it will
not permit any client to connect this DVR system.
【
Remote Disp Use Port
】
Select remote connection port for Clients.
【
Net Send Priority
】
There are three items selected.
"
smooth‖ sets the system to have a large
buffer.
"
realtime
"
sets the system to have enough bandwidth. Otherwise, the data off and on when
it is sent from the network.
【
PDA Connection
】
Select whether allow PDA connect to DVR system.
If you select
―disable‖,
it will not permit any PDA device connect this DVR system.
Note:
To use PDA connection normally, the board card should support dual compression and user must set dual
setting in local setup (can’t set remote image same as recording).
【
PDA Connect Port
】
Select remote connection port for PDA device.
【
Alarm Auto Connect
】
Assign a network client to receive alarm message when there is an
alarm. The alarm channel image will auto display in the client software. But user must be sure that
client is running on that IP address.
Note:
Alarm auto connection to IP is used to input alarm automatically. When sensor, normal or motion record
is set to input and there is an IP address, the system will check if the client has connected with this
system. If there is no connection, the system will try to connect with it through Port 5300(preset). While
it cannot be connected, the system will keep trying till the connection is OK.