background image

- 6 - 

 

I

NSTALLATION 

P

ROCEDURES 

 

Clean Ice Maker 

Clean your ice maker to industry standards. The Sanit-ICE

® 

System is 

designed  to  keep  a  clean  ice  maker  from  becoming  dirty.  It  will 
sterilize a dirty ice maker, but it will still appear dirty. 

Unpacking 

Make  sure  all  of  the  components  are  in  the  box  before  beginning 
installation of the Sanit-ICE

® 

System. In addition to this manual, you 

should  have  (1)  Sanit-ICE

® 

unit,  (1)  z-bar  mount,  (10ft)  tube,  (1) 

rubber grommet, and (1) diffusor. 

Locate a Mounting Location 

Before  beginning  the  installation,  locate  a  suitable  location  for  the 
Sanit-ICE

® 

System. Find a flat portion of a wall, close to the ice maker. 

The unit may also be placed on a flat, level surface. Please consider 
the following when selecting a mounting location: 

• 

Never install the Sanit-ICE

® 

System in an area where water may 

freeze. Freezing water will damage the internal components.

 

• 

The  Sanit-ICE

® 

System  is  mounted  horizontally.  Refer  to  the 

installation instructions. Do not mount vertically or at an angle. 
Always use a level when installing this unit.

 

• 

The Sanit-ICE

® 

System is close enough to a power outlet so an 

extension cord is not necessary.

 

• 

The Sanit-ICE

® 

System is to be mounted no further than 10 feet 

from the point of use.

 

 

Mount the Sanit-ICE System above the entry point of the ozone 

line into the ice machine.

 

Mount the Sanit-ICE

® 

System 

 

Use the appropriate tools and mounting hardware (not provided) 
for the material the wall is constructed from and install the z-bar. 
Use a level to make sure it is horizontal.

 

• 

Place the Sanit-ICE

® 

System onto the z-bar.

 

Summary of Contents for Sanit-ICE

Page 1: ...OptiPure a Division of Aquion Inc Commercial Water Filtration Systems 101 S Gary Ave Suite A Roselle IL 60172 972 881 9797 E mail info optipure net www optipurewater com Copyright 2018 OptiPure Repro...

Page 2: ......

Page 3: ...or maintenance procedure associated with this equipment Failure to follow these instructions could result in personal injury damage to the equipment or reduced product performance In an ongoing effor...

Page 4: ...tions 4 Installation Procedures 6 Figure 1 Feature Callout 7 Figure 2 Typical Installation 7 Operating Instructions 8 Figure 3 Summary of LED Indicators 8 Trouble Shooting 9 Servicing 9 Appendix A Spe...

Page 5: ...gen leaving no harsh chemical residue and discharging no harsh chemicals into the water No chemicals mean the taste of the water and subsequent ice produced is not negatively impacted This unit will a...

Page 6: ...using harsh chemicals abrasives or cleaners 7 Warning The unit has only been evaluated for mechanical electric shock and fire hazards The method to control ozone release or the effectiveness of the w...

Page 7: ...stalled and grounded in accordance with all local codes and ordinances 12 WARNING Improper connection of the appliance grounding conductor can result in a risk of electric shock Check with a qualified...

Page 8: ...l surface Please consider the following when selecting a mounting location Never install the Sanit ICE System in an area where water may freeze Freezing water will damage the internal components The S...

Page 9: ...in ice maker Attach the opposite end of the tubing to the barbed fitting of the diffuser provided and place the diffuser into the water reservoir Plug the Sanit ICE System into a GFCI protected outle...

Page 10: ...roduced at the beginning of a cycle for a time period based on your profile and the unit must reach a new cycle before ozone is produced again In the event of power loss the Sanit ICE System will reme...

Page 11: ...ing any maintenance procedures As Needed Clean fan filter Remove fan cover by grasping the fan grill witha pair of needle nose pliers and gently pulling Take out foam filter wash filter with warm soap...

Page 12: ...mm Outlet 3 16 Barb Power 120 240 VAC 50 60 Hz Power Connection 6 1 8m 3 prong cord Mounting Z bar Ambient Conditions 32 95 F 0 35 C 10 90 RH non condensing Shipping Weight 3 5 lbs 1 6 kg Performance...

Page 13: ...11 Appendix A Specifications Ozone Generator Power Supply Ozone Outlet Air Compressor Power Cord Control Board Ozone Cell Fan...

Page 14: ...t misuse alteration or abuse An act of God such as flood earthquake hurricane lightning or other disaster resulting only from the forces of nature Normal wear and tear Operation outside the usage para...

Page 15: ...any and all warranties For service contact your authorized dealer or distributor or OptiPure direct at 972 881 9797 Exclusive Warranty There is no other expressed warranty on OptiPure products and or...

Page 16: ......

Reviews: