- 9 -
T
ROUBLE
S
HOOTING
Light does not come on
•
Verify the unit has power
•
Push the mode select button to see if the unit will cycle
through different modes
Bubbles do not come out of diffusor
•
Make sure that the indicator LED is blinking. If the light is on
but not blinking, the unit is in standby. Wait for 10 minutes
for another ozone cycle to occur.
•
Clean the diffuser (see servicing for details)
S
ERVICING
Note
Disconnect power from unit before performing any maintenance
procedures.
As Needed
Clean fan filter: Remove fan cover by grasping the fan grill with a
pair of needle nose pliers and gently pulling. Take out foam filter,
wash filter with warm soapy water, allow to dry, and re-install.
Clean Diffuser: submerse diffuser in vinegar for 2 hours and rinse
clean.
Red Light Illuminated
The light on the Sanit-ICE
®
system will turn red after the ozone cell
has run for approximately 9000 hours. This will typically take
between 1 and 3 years depending on which mode the unit is in. At
this time the unit needs to be serviced. Servicing includes replacing
the ozone generator and barbed ozone outlet fitting.