OPTILAB ASE-C-MSA Series User Manual Download Page 13

 

ASE-C-MSA 

User’s Manual

 

Page 10 of 10 

Optilab, LLC

 

600 E. Camelback Road, Phoenix, AZ  85012 
Phone:  (602) 343-1496, Fax:  (602) 343-1489, Email:  [email protected] 

industrial grade 99% pure isopropyl alcohol and follow the procedures below to 
keep the connectors, adaptors and receptacles clean. 

Cleaning Optical Connector End-face with Wipe and Alcohol 

To  properly  clean  optical  connectors  utilizing  lens  tissue  grade  wipes  and  alcohol 
follow  the  procedure  below.  The  moist  wipe  removes  dust  particles,  oil  and 
contaminants  that  may  damage  or  blot  the  end-face  of  the  connector  during 
connection.  The  dry  wipe  removes  residual  alcohol  that  may  be  ignited  by  optical 
emission. 

1.  Disable the optical output and turn off unit to prevent accidental exposure or 

damage to the optical connector by optical emission. 

2.  Moisten a wipe with alcohol by placing on top of the alcohol dispenser and 

push down to saturate the wipe. 

3.  Place the moist wipe on a work surface, and place a second dry wipe next 

to it. 

4.  Wipe  the  optical  connector,  end-face  down  on  the  moist  wipe  3  times  and 

then repeat on the dry wipe. 

5.  Visually  inspect  the  end-face  of  the  optical  connector  with  an  optical 

microscope to verify cleanliness. Repeat steps 2 to 5 as needed. 

 

Cleaning Optical Connector Sides, Receptacles, Adaptors with Swab and 
Alcohol 

Dust or particles can adhere to the insides of receptacles and adaptors or the sides of 
the  optical  connector  ferrule.  Their  presence  can  affect  the  alignment  of  the  optical 
fiber  connectors  and  increase  connection  loss.  To  properly  clean  optical  connectors, 
receptacles, and adaptors utilizing a swab and alcohol follow the procedure below: 

1.  Disable the optical output and turn off unit to prevent accidental exposure or 

damage to the optical connector by optical emission. 

2.  Moisten  the  swab  by  placing  it  on  top  of  the  alcohol  dispenser  and  push 

down to saturate the swab. 

3.  For receptacles, adapters, or other connection points, insert the moistened 

swab  and  rotate  the  tip  1/2  turn  clockwise  and  counter-clockwise  6  times 
while applying light but firm pressure.  

4.  For  fiber  connectors,  rotate  the  tip  of  the  moistened  swab  5  revolutions 

around the connector while applying light but firm pressure. 

5.  Visually inspect the end face of the connector with an optical microscope to 

verify cleanliness. Clean end-face as needed. 

 

Summary of Contents for ASE-C-MSA Series

Page 1: ...read this manual before operating the ASE C MSA unit Operations other than those described in this manual may result in personal injury and damage to the unit Note that any attempt to open or fix the...

Page 2: ...ory VERSION DATE CONTENT 1 0 10 28 2021 Manual introduced Copyright 2021 by Optilab LLC All rights reserved This document is copyrighted property of Optilab LLC It may not be used in whole or in part...

Page 3: ...1 1 2 PRODUCT OVERVIEW 1 1 3 FEATURES 1 1 4 USER SAFETY 1 2 OPERATION 2 2 1 INTRODUCTION 2 2 2 INITIAL INSPECTION 2 2 3 PANEL DIAGRAM AND CONTROLS 2 2 4 PIN OUT DIAGRAM 4 2 5 OPERATION INSTRUCTIONS 5...

Page 4: ...ensure constant output power and emission wavelength stability The module can be controlled through a computer by using a USB or RS 232 interface the user can control the ASE source output power leve...

Page 5: ...red in transit If the shipping container or the packing material is damaged keep it until the contents of the shipment have been checked to be free of mechanical and electrical damages Notify Optilab...

Page 6: ...supply form Option 1 uses a 4 Pin Molex connector which is compatible with Optilab PM 5 M 5V power supply module Option 2 uses a single 5V power jack connector FEATURE FUNCTION ASE MODULE CONNECTOR P...

Page 7: ...er USB or RS232 INTERFACE SELECTOR This 3 pin jumper pairs can be connected correspondingly to enable USB interface or RS 232 interface LED INDICATOR FOR MODULE POWER Display for power state of the ad...

Page 8: ...n out diagram for the RS 232 port on the external of the power adapter 2 5 Operation Instructions Start up Procedure 1 Make sure the three optical output FC APC connectors of the ASE module are proper...

Page 9: ...the laser current can be adjusted using the PC Turn off Procedure 1 Set the pump current to be zero to turn off the laser 2 Exit and close the command setting window of the module 3 Press the power sw...

Page 10: ...now able to send commands to the ASE module The commands are listed below Command Description Example Response READ Reads the equipment basic information READ CR LF Optilab LLC Model Type ASE C MSA 3...

Page 11: ...ical adapters or connectors S Use only the indicated optical adapters and connectors If measurement instruments accept different connector type then use hybrid patchcords C Optical output connector da...

Page 12: ...tees its ASE C MSA module is guaranteed to be free of defects for 1 year from the date of shipment The guarantee does not cover any damages resulting from the misuse or improper handling of the equipm...

Page 13: ...n repeat on the dry wipe 5 Visually inspect the end face of the optical connector with an optical microscope to verify cleanliness Repeat steps 2 to 5 as needed Cleaning Optical Connector Sides Recept...

Reviews: