OPTIKON Keratron Piccolo Installation And Operating Manual Download Page 5

Keratron

   Piccolo                                                   Installation and operating manual 

OPTIKON 2000 

 

1 DISCLAIMER 

OPTIKON 2000 S.p.A. requires the user of this system to carefully read specific 
warnings found in this manual.  It is responsibility of the user to provide its personnel 
with a thorough understanding of the equipment operation before use.  In no event 
shall Optikon 2000 S.p.A. be liable for any injury, incidental or consequential 
damages incurred by the purchaser, users or patients as a result of operation of the 
product.  

Use of this system is a matter of professional medical judgment. Optikon 2000 S.p.A. 
is not responsible for any clinical problem resulting from mishandling this equipment 
and makes no medical recommendations. 

OPTIKON 2000 S.p.A. declares to be responsible for the safety, reliability and 
performance only if: 

  updates, calibrations and repairs are carried out by personnel which has been 

authorised by OPTIKON 2000 S.p.A.;  

  the system is used in compliance with the user instructions  

  the mains electric installation to which the system is connected complies with 

the IEC Safety Regulations. 

 

IMPORTANT NOTICE: 

Every effort has been made so that all the illustrations and information 
precisely represent the product and its operation as they were at the time this 
manual was printed. It is possible, however, that during the existence of this 
manual modifications have been made in order to continue to effectively 
satisfy the needs of the users. At times, such modifications are made without 
advance notice.

 

 
 

OPTIKON 2000 S.p.A. 

Via del Casale di Settebagni 13 

00138 Roma 

Phone +39 06 8888355 

Fax +39 06 8888440 

e-mail 

[email protected]

 

www.optikon.com

 

 

NOTICE: The information contained in this manual is the exclusive property of 
OPTIKON 2000 S.p.A. Partial or total reproduction of this manual is permitted only 
upon written authorisation by OPTIKON 2000 S.p.A.

 

Cod. 161301EN

 

1-1

 2012-01-17 

Rev.D  

 

Summary of Contents for Keratron Piccolo

Page 1: ...7 Rev D KERATRON PICCOLO Videokeratoscope INSTALLATION AND OPERATING MANUAL OPTIKON 2000 S p A Via del Casale di Settebagni 13 00138 Rome Italy Phone 39 06 8888355 Fax 39 06 8888440 e mail sales optik...

Page 2: ...O 9001 and ISO 13485 certified company that manufactures surgical and diagnostic devices for ophthalmology All Optikon 2000 products are manufactured in compliance with the requirements of Directive 9...

Page 3: ...NSTALLATION 6 3 6 4 1 INTRODUCTION 6 3 6 4 2 DOWNLOAD THE SCOUT SOFTWARE FROM THE WEB 6 4 6 4 3 SCOUT SOFTWARE INSTALLATION 6 5 6 4 4 IMPORTING OLD KERATRON TESTS 6 5 6 4 5 SCOUT SOFTWARE STRUCTURE 6...

Page 4: ...10 INDEX 10 1 11 APPENDIX 11 1...

Page 5: ...e carried out by personnel which has been authorised by OPTIKON 2000 S p A the system is used in compliance with the user instructions the mains electric installation to which the system is connected...

Page 6: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK Cod 161301EN 1 2 2012 01 17 Rev D...

Page 7: ...uthorised OPTIKON S p A technical service OPTIKON 2000 S p A reserves the right to verify in case of failures if the instrument and or its accessories have been modified or tampered with in any way or...

Page 8: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK Cod 161301EN 2 2 2012 01 17 Rev D...

Page 9: ...nd good image acquisitions see in particular the chapters dedicated to the eye acquisition and the last page of this manual and eventually corrected by properly using Photo Process Editing functions T...

Page 10: ...tive ground the DISPERSION CURRENT IN THE COVERING of the entire system can become excessive due to the value of the dispersion current in the covering of the nonconforming device Under these conditio...

Page 11: ...re used in the Keratron Piccolo and Base labels Before using the unit familiarize yourself with the symbols and definitions provided in the table SYMBOLS PUBLISHED BY IEC SYMBOL DESCRIPTION ALTERNATIN...

Page 12: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK Cod 161301EN 4 2 2012 01 17 Rev D...

Page 13: ...from five virtual LEDs located to the left of the live image The VK carries 28 mires which are shaped as back lighted concentric rings alternatively 14 black and 14 whites arranged into the internal...

Page 14: ...era and that is an important reference point for all corneal maps The entrance pupil is also detected 5 2 TECHNICAL SPECIFICATIONS PARAMETER SPECIFICATIONS Manufacturer OPTIKON 2000 S p A Via del Casa...

Page 15: ...function Misalignement Mean deviation on the map 0 1 with misalignement up to 1mm EQUIPMENT CLASSIFICATION ACCORDING TO IEC 60601 1 Type of protection against electric shock Base Class I Keratron Pic...

Page 16: ...00 Depth 210 mm Weight about 1 000 g KERATRON PICCOLO Height 250 mm Width 110 mm Depth 160 mm Weight about 1 000 g NOTES The weight and dimensions indicated are approximate 2 Specifications are subjec...

Page 17: ...nce RF emissions CISPR 11 Group 1 The Keratron Piccolo uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby elec...

Page 18: ...cles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Mains power quality should be that of a typical commercial or hospital environment If the user of the Keratron Piccolo requires contin...

Page 19: ...WEEN PORTABLE AND MOBILE RF COMMUNICATION EQUIPMENT AND KERATRON PICCOLO Keratron Piccolo is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The cus...

Page 20: ...power supply Base cable for connection to the power supply calibration sphere multifunction cable footswitch software and user manual 5 6 ACCESSORIES THAT CAN BE PROVIDED SEPARATELY MODULE CODE DESCR...

Page 21: ...video mode at least 1024x768 pixels true color 32 bit USB Port 2 0 Windows XP SP2 Windows 2000 SP4 Windows Vista 32 bits Color Graphic printer Slit lamp Any having an 8 mm hole diameter between 7 8 a...

Page 22: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK Cod 161301EN 5 3 2012 01 17 Rev D...

Page 23: ...raphy system 6 2 UNPACKING AND INSPECTION The unit has been packed to reduce the risk of damage during shipping to a minimum Open the package and examine the components When opening the package handle...

Page 24: ...e where the videokeratoscope can be placed when it is removed from the slit lamp 2 Standard 28 ring mires cone 3 Videokeratoscope 4 Wheel for attachment on the slit lamp 5 Personal Computer with USB 2...

Page 25: ...A in its circular socket on the back of the Base itself paying extremely careful attention to the alignment marks I 3 Connect the footswitch to the Base Fig 2 4 Connect the PC to the videokeratoscope...

Page 26: ...ut it must be a true color 65K or 16M colors It is however recommended a screen size of at least 1024x768 pixels 3 Do not alter any of the system files installed by the Scout Setup software nor any fi...

Page 27: ...n if you are registered or not IF YOU ARE NOT REGISTERED Click on the Keratron Scout update page hyperlink in the menu Select New User Registration Follow the operations that appear on the screen You...

Page 28: ...e downloaded version Using Windows Explorer select the folder where the downloaded files are Run the Setup exe by double clicking on it 6 4 4 IMPORTING OLD KERATRON TESTS The exams file format of Kera...

Page 29: ...he list showed il the Test Manager verify that each name surname sex DOB test number and test date are imported correctly You can change the import parameters using Tools Options select the Database s...

Page 30: ...ew The SW puts here temporary files tb Toolbar settings Scout ini Software settings chm Localized help files ScoutTSE exe Trial set editor for lenses Scout exe Main program ScoutPad exe Print template...

Page 31: ...t and will display the Dialog Box Add New Hardware Wizard Click on the Next button Select in the next window the radio button Search for a suitable driver for my device Recommended and then click the...

Page 32: ...of enabling the USB communication in the Scout software Start the Keratron Scout software In the menu bar select Tools then select the item Option The dialog window will display what is shown in Fig...

Page 33: ...4 Click on the Add Remove button 5 Follow the instructions if the uninstall procedure asks you to remove some DLLs click on the Yes to all button The second one calls directly a specific unistall util...

Page 34: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 C Keratron Test Scout exe C Keratron Test Piccolo exe Finally restart your PC Cod 161301EN 6 11 2012 01 17 Rev D...

Page 35: ...SCREEN DESCRIPTION 7 1 INTRODUCTION In this section only the basic operation are described For a more comprehensive and updated description of the software functions refer also to the HELP menu comman...

Page 36: ...nd forth so to be sure to be in the middle of the OK zone Press the footswitch and wait that the image is transferred to the PC Then the software will ask the operator to verify that there are no trac...

Page 37: ...virtual OS or OD key or the S key and the D key on the PC s keyboard is pressed the window goes from standby to the acquisition state in which a beeping sound signals the new state and on the PC s sc...

Page 38: ...use the joystick of the slit lamp to get to the proper distance from the eye The lower LED with an arrow pointing upward indicates that you should move closer to the eye The upper LEDS with arrows po...

Page 39: ...ort beeps whose tone and rhythm vary this is an acoustic signal for the user while he aligns the eye to capture its image Learning to recognize the different sounds will allow the user to concentrate...

Page 40: ...4 HOW TO PROCESS PRINT AND SAVE IMAGES After Acquisition you can process individual images by double clicking on them but it is advisable to process all of them by the Process All menu or icon button...

Page 41: ...button Discard all images except for the best one for each eye This will save space on disk and will speed up the check If you did not do it before fill in patient form Always put the name and date of...

Page 42: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK Cod 161301EN 7 8 2012 01 17 Rev D...

Page 43: ...sis the optical head can be removed and cleaned inside To perform this operation you must Grab the mires cone by its round flap with your full hand and remove it Clean inside the hole by blowing with...

Page 44: ...Keratron Piccolo Installation and operating manual OPTIKON 2000 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK Cod 161301EN 8 2 2012 01 17 Rev D...

Page 45: ...file must be used if 1 The SW hangs when starts When this occurs try to rename not delete the Scout ini file and restart the SW 2 Runtime error exporting tests When this occurs open the Scout ini file...

Page 46: ...Database list 9 4 CHANGING THE PC Backup the Database s on network cd rom Backup the C Keratron Scout ini file options settings MRU path Backup the C Keratron tb file toolbar settings Change the PC Re...

Page 47: ...sence of resident software that could interfere with USB port Check the icons in Windows Toolbar bottom right side and de activate them The live image on the virtual panel moves in a jerky manner c Ke...

Page 48: ...bels are non readable cutted or new paragraph a Check the video board and its drivers try different video mode and settings Check that no programs or settings in Windows can be cause of such a behavio...

Page 49: ...ave it again with the DAO 3 5 version prior Access database version No test is visible in the database explorer a An empty database has been selected b Check whether the Group selection has been press...

Page 50: ...ECTOR B 6 3 FIG 4 COMPLETING THE USB DRIVER INSTALLATION 6 9 FIG 5 OPTIONS WINDOW 6 9 FIG 6 PRINT I O SECTION 6 10 FIG 7 VIRTUAL PANEL 7 1 FIG 8 VIRTUAL PANEL IN STANDBY SUPERIMPOSED ON THE PHOTO ACQU...

Page 51: ...ensions 5 4 dispersion current 3 2 disposal of waste electrical and electronic equipment 3 1 driver 6 7 E electrical specifications 5 2 entrance pupil 5 2 EPCS 5 3 Equipment classification 5 3 F focus...

Page 52: ...eratron Piccolo Installation and operating manual OPTIKON 2000 unistall utility 6 9 USB 6 7 V vertex 5 3 5 2 7 2 7 3 W warnings 3 1 windows XP 6 3 wiring Diagrams 5 4 Cod 161301EN 10 2 2012 01 17 Rev...

Page 53: ...line The eyelashes shadow is under the horizontal line The map shows a high energy zone High energy zone Artifacts due to the presence of eyelashes Suggestions Instruct the patient to OPEN BOTH EYES...

Reviews: