background image

 

 

NLV-5201 

Fixed Position 2D Imager Scanner 

User's Manual 

Summary of Contents for NLV-5201

Page 1: ...NLV 5201 Fixed Position 2D Imager Scanner User s Manual ...

Page 2: ...ective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental damages arising o...

Page 3: ...unplug the cable and AC adapter then contact your dealer if If the cable jacket tears open or separates from the connector If any core wire become exposed If the cable generates heat even if it looks normal Continued use in any of these conditions may cause malfunction overheating and or fire Operating environment Do not use this product at temperatures outside the specified range Do not use this ...

Page 4: ...ncluding interference that may cause undesired operation Regulatory Compliance 1 LED Safety IEC 62471 Exempt Risk Group 2 EMC EN 55024 EN 55032 Class B FCC Part 15 Subpart B Class B VCCI クラス B Disclaimer OPTOELECTRONICS CO LTD Will not bear any responsibility in case of malfunction accident repair and damage assurance この装置は クラスB機器です この装置は 住宅環境で使用することを目的としています が この装置がラジオやテレビジョン受信機に近接して使用されると 受信障害を引...

Page 5: ...NLV 5201 User s Manual iii 1st Revision History Document Name NLV 5201 User s Manual Edition Date Page Section Description of Changes Prelimina ry 2019 02 22 Initial release ...

Page 6: ...led View 15 2 6 Operation Mode and Control Panel Description 16 2 7 Operation Mode 16 2 7 1 Control Panel Operation Specifications 17 2 7 2 LED Indicator Specifications 18 2 7 3 Buzzer and LED Indicator 19 2 7 4 Operation Transition 20 2 8 Normal Trigger 20 2 8 1 Auto Trigger 21 2 8 2 Operation Invalid Transition Diagram 22 2 8 3 Installation of the Scanner 23 2 9 Scan Area 24 2 10 Image Range 24 ...

Page 7: ...8 Enable Disable Mode Key 38 3 3 9 Direct Numerical Input Command 39 3 3 10 4 Indicator Options 40 Buzzer 41 4 1 Buzzer Loudness 41 4 1 1 Good Read Buzzer 41 4 1 2 Start up Buzzer 42 4 1 3 Read Timeout Buzzer 42 4 1 4 Intermediate Buzzer 42 4 1 5 Status LED 43 4 2 Status LED Lighting Time 43 4 2 1 Good Read Aiming 44 4 3 Indicator in General 45 4 4 Indicator Timing 45 4 4 1 5 Interface 46 RS 232C ...

Page 8: ...ing 67 6 1 1 Command Trigger Control 68 6 1 2 External Trigger Signal Control 69 6 1 3 Read Time Setting 70 6 1 4 Trigger Delay 71 6 1 5 Decode Timeout 72 6 1 6 OK NG Signal 73 6 2 Enable Disable OK NG signal 73 6 2 1 OK NG Signal Behavior Settings 74 6 2 2 7 Tuning and Bank Function 75 Tuning Overview 76 7 1 Tuning Function 76 7 1 1 Tuning Setting Flow 77 7 1 2 Tuning 78 7 2 Execute Tuning 78 7 2...

Page 9: ...93 9 1 3 GS1 Composite Code 93 9 1 4 2D Codes 94 9 1 5 Other Options for Codes 94 9 1 6 OCR 95 9 1 7 Setting of Code Common Options 96 9 2 GS1 Convert 96 9 2 1 Positive and Negative Image of Barcodes 1D code common 97 9 2 2 Redundancy 1D code common 98 9 2 3 Add on waiting time 98 9 2 4 ECI Protocol Output 99 9 2 5 OCR Free Edit 100 9 2 6 Setting of Code Specific Options 101 9 3 UPC 101 9 3 1 EAN ...

Page 10: ...3 ASCII Prefix Suffix Values 131 10 1 4 Code ID 132 10 1 5 Code Length 132 10 1 6 Code Coordinates 133 10 1 7 Scan Time 134 10 1 8 Case Conversion 135 10 2 11 Appendix 136 Code ID Table 137 11 1 Opticon Code ID prefix suffix value 137 11 1 1 Code Option AIM ISO15424 Code ID prefix Suffix value 138 11 1 2 NLV 5201 Specification Overview 142 11 2 Common Specification Overview 142 11 2 1 Technical Sp...

Page 11: ...act NLV 5201 User s Manual 1 1st 1 Abstract This document provides the user s manual for the NLV 5201 2D handy scanner hereafter called scanner 1 1 Feature of the Scanner 1 2 Usage of the Scanner 1 3 Flow to Integrate ...

Page 12: ...on automation applications 3 Focus Model NLV 5201 has 3 focus models to choose from The standard model fixed focus 113mm A High Density model HD 63mm focus and Ultra Density UD 43mm focus models Data edit programming data output formatting This scanner features a unique script program function called Data Editing which gives a user an almost unlimited flexibility to format the scanned data before ...

Page 13: ...e control has auto adjustment and tuning Select according the usage Industrial use Common use Example of use Factory line etc Example of use Holing an product to read etc Exposure Control Tuning Auto Adjustment default When reading distance and the code to read is fixed reading will stabilized by setting the optimum exposure Adjust exposure automatically when the reading distance and the code to r...

Page 14: ...w Refer to 11 2 2 Download Tools According to the operation download necessary tools from our website Install condition image confirmation tuning and other settings UniversalTuningTool UniversaTuningTool For USB COM USB Driver 3 Fixing Position and Setting for operation Confirm the optimun setting according to the operation Configurations Refer to 3 Interface Refer to 5 Reading and Timing Refer to...

Page 15: ...According to the operation download necessary tools from our website Setting Image acquisition confirm communication UniversalConfig UniversalConfig USB COM USB Driver 3 Setting and Testing In the actual enviroment evaluate the optimum setting according to the operation and perform a reading test Configurations Refer to 3 Indicator Refer to 4 Interface Refer to 5 Code Options Refer to 9 String Opt...

Page 16: ...ng 2 1 Model Details 2 2 Package Contents 2 3 Connect to the Host 2 4 How to Read 2 5 Depth of Field and Focus Type 2 6 Detailed View 2 7 Operation Mode and Control Panel Description 2 8 Operation Transition 2 9 Installation of the Scanner 2 10 Scan Area 2 11 Scanned Media and Placement 2 12 When Placing Exit Window ...

Page 17: ...tion 2 1 2 Focus Symbol Description None Standard focus model focus distance 113 mm HD High density focus model focus distance 63 mm UD Ultra high density focus model focus distance 43 mm Interface Cable Symbol Description RS232C LE RS 232C loose end cable open wires no connector USB USB cable is connected and interface default setting is USB HID USB COM USB cable is connected and interface defaul...

Page 18: ...roduct Please check before using Following are included to USB interface model Scanner with USB cable NLV 5201 Quick Start Guide 1 copy Following are packed to RS 232C interface model Scanner with RS 232C loose end cable NLV 5201 Quick Start Guide 1 copy USB HID USB COM Interface Model RS 232C Interface Model ...

Page 19: ...nterface connector to the host When power is on the scanner makes startup sound After startup sound is completed the scanner will be ready for reading USB COM and USB HID interface can be changed by the setting For the USB COM interface model the Opticon USB COM driver must be installed on your host device While using USB COM and not connected to the host the scanner makes an error sound when read...

Page 20: ... output terminal Orange NG External NG output terminal Black S GND Gray RTS Blue CTS Green TxD White RxD Black Shield GND Heat shrinkable tube Loose end Circuit X X X X X X 1500 60 Φ 3 8 AWG28 Unit mm Host RS 232C Communication connector Barcode reader main circuit VCC DC 5V Load MAX DC 24V TxD RxD RTS CTS OK NG Trigger S GND F GND TxD RxD CTS RTS External device NLV 5201 RS 232C Loose End Interfa...

Page 21: ...al communication RS 232C USB COM 2 Turn ON external trigger input RS 232C loose end 3 Detect target to read in auto trigger mode 4 Press trigger key Used when testing and maintenance etc Reading Reference Standard mode SR Approx 113 cm Scan Area Refer to 2 10 Distance Refer to 2 5 1 High Resolution model HD Approx 63 cm Refer to 2 5 2 Ultra High Resolution model UD Approx 43 mm Refer to 2 5 3 ...

Page 22: ...hart 15 from the optical axis 25C Refer to 11 2 2 Technical Specifications Standard Model Reading Depth of Field for specified value 0 127mm 5mil 53 126 0 254mm 10mil 52 237 0 508mm 20mil 69 433 0 20mm 7 9mil 191 62 0 33mm 13mil 50 291 0 169mm 6 7mil 49 146 0 254mm 10mil 42 211 0 169mm 60 111 0 381mm 15mil 22 250 0 169mm 6 7mil 62 116 0 254mm 10mil 173 43 0 50 100 150 200 250 300 0 50 50 25 25 75 ...

Page 23: ...Technical Specifications High Resolution Model HD Reading Depth of Field for specified value 0 50 100 150 200 0 50 50 25 75 75 25 Code 39 Code 128 EAN UPC PDF417 QR Code Data Matrix 0 076mm 3 0mil 45 72 0 127mm 5 0mil 35 119 0 254mm 10mil 55 179 0 20mm 7 9mil 159 68 0 33mm 13mil 48 200 0 127mm 5 0mil 39 109 0 254mm 10mil 46 154 0 127mm 5 0mil 43 91 0 381mm 15mil 24 180 0 127mm 5 0mil 48 78 0 254mm...

Page 24: ...rt 15 from the optical axis 25C Refer to 11 2 2 Technical Specifications Ultra High Resolution model UD Reading Depth of Field for specified value 0 0 25 50 Unit mm Code 39 EAN UPC QR Code Data Matrix 0 076mm 3mil 28 65 0 127mm 5mil 23 82 0 254 10mil 53 108 0 33mm 13mil 50 0 084mm 3 3mil 33 55 0 381mm 15mil 22 109 25 50 75 100 25 50 120 0 084mm 3 3mil 35 55 0 254mm 10mil 22 86 ...

Page 25: ... bank 4 Buzzer Holes Sound from a built in buzzer comes out through these holes When they are covered the buzzer sound will be diminished The sound varies depending on the settings Buzzer sound settings are configurable for frequency loudness and duration 5 Status LEDs Indicates status by the combination of 3 color LEDs red orange green Refer to 2 7 3 LED Indicator Specifications for detail 6 Trig...

Page 26: ...ed when testing the read rate The read rate is displayed on the indicator LED every 10 times Tuning mode TUNE When reading distance and the code to read is fixed reading will stabilized by setting the optimum exposure When the tuning is successes code limited and exposures setting etc are registered to the current bank Also the reading rate is displayed on the LED indicator Bank Area to register t...

Page 27: ...ing is successes is displayed on the LED indicator Press 3 times within 2 sec Mode transition by pressing once Aiming In the aiming mode aiming lights and if code can be read displays whether the code is close to the center coordinate of the image sensor to indicator LED Press 4 times within 2 sec Press 2 seconds or more Press again to select Mode transition by pressing once Bank selection By pres...

Page 28: ...mmunication Reading error LED indication Test mode Tuning mode and Aiming mode LED indication Test and tuning display the reading rate for 10 times Reading rate 0 40 50 70 80 90 100 Central coordinate Within 1 2 image Within 1 4 image Within 1 8 image Within 1 16 image LED indication Judgement range at aiming Bank No LED indication The LED of the bank currently used will blink by pressing the mode...

Page 29: ...Z menu Reading sound When reading start ZZ menu code Middle Middle low Middle high tone Yellow Enable Fixed When reading defined menu code Middle Middle low Middle high tone Yellow Enable Fixed When reading not defined menu code Low tone 2 times Red Enable Fixed When reading end ZZ menu code Middle Middle low Middle high tone Yellow Enable Fixed When save setting is complete Middle Middle low Midd...

Page 30: ...Can start reading by serial command pushing side trigger or the external trigger input becomes active Reading operation stop The reading operation can be stopped by a successful decode a stop command or a timeout period after release of the trigger Reading operation stop is configured using commands This cannot be done while using USB HID interface Power OFF Standby Read Non Operation Power applie...

Page 31: ... m m a n d Status Description Status Description Read Processes reading Illumination fully ON Auto trigger standby When the target is within the scan area and detected the scanner starts the reading mode AIM pulses Auto trigger sleep Auto trigger mode will sleep after 60 seconds default time This sleep time can be re configured or disabled Reading operation stop Operation of the scanner is stopped...

Page 32: ...2 8 3 For USB COM and RS 232C scanner operation can be disabled by command s serial communication When disabled auto trigger operation becomes invalid Refer to 3 3 6 for setting command Read Operation Enable Read Operation Disable Read operation enable command Read operation disable command ...

Page 33: ...e acceleration is applied via the contact surface However the scanner cannot withstand direct shock since it consists of precise optical elements NLV 5201 Installation Recommend screw type M3 Recommend torque Less than 20 Ncm Maximum screw depth 3 5 mm from the mounting surface of the scanner Dimensions Approx 41 1 W 33 0 H 24 0 D Weight Approx 30 g excluding cable Cable 1 5 m Please contact sales...

Page 34: ...ew The range is 5 from the following values Image Range L Distance from the front edge of scanner mm 40 60 80 100 120 140 160 180 Horizontal FOV mm 29 6 43 4 57 1 70 9 84 7 98 5 112 3 126 0 Vertical FOV mm 22 1 32 4 42 7 53 0 63 3 73 6 83 9 94 2 The table above shows the field of view which should not be obstructed by any parts of a housing Horizontal image width Vertical image width Aiming width ...

Page 35: ... window with sufficient clearance with respect to the optical path as depicted below Obtain the image in the actual environment and evaluate it The software tools for image capture can be found on the Opticon website Horizontal Field of View Illumination LED Vertical Field of View Illumination LED Vertical Horizontal Standard SR Focus 113 mm Aiming LED Aiming LED HD Focus 63 mm UD Focus 43 mm ...

Page 36: ...tive surface Solution Specular reflection does not occur when an angle is created between the scanner and the target label as shown in the figure below The conditions for the occurrence of specular reflection depend on the distance L and the inclination angle θ The recommended inclination angle is about 15 degrees Note that as the angle becomes bigger it becomes more difficult to read the target l...

Page 37: ...play Strong ambient light fluorescent and sunlight causes a specular reflection on metal surface or glass surface of display Solution It is recommended to shield the reading position from strong ambient light Obtain the image in the actual environment and evaluate it The software tools for image capture can be found on the Opticon website Shade Scanned target ...

Page 38: ...t For the best optical quality use an acrylic material cast or extruded Select a high quality achromatic acrylic material with a smooth flat surface without scratches and dents Use acrylic material with an anti reflective AR coating applied to both sides Apply an anti scratch coating to the surface of the exit window to protect it from scratches during operation Hard coated acrylic sheets are read...

Page 39: ... vertically Obtain the image in the condition range to be used and design placement so that there is no reflection of the LED illumination Keep a minimum clearance between the scanner and the exit window of 1mm because of the dimensional tolerances of the mounting holes Use of AR coated material for the exit window is recommended External light is not factored in Confirm that there is no reflectio...

Page 40: ...201 User s Manual 30 1st 3 Configurations This chapter explains the scanner configuration default setting and saving setting and basic commands 3 1 Configuring with Commands 3 2 Command Packet Sending Precautions 3 3 Basic Commands ...

Page 41: ...It is possible to send multiple command IDs between a single header and terminator except for single digit IDs 2 A combination of command header STX 0x02 and terminator ETX 0x03 is also possible Input examples 1 digit command ESC Δ CR 2 digit command ESC ΔΔ CR 3 digit command ESC ΔΔΔ CR Two 2 digit commands ESC ΔΔΔΔ CR 2 and 3 digits command ESC ΔΔ ΔΔΔ CR Command can be sent via UniversalConfig Co...

Page 42: ...nly one 2D menu code Scanning a 2D menu code will always perform a save settings upon completion so a Z2 command to save current settings is not needed Data Packet MENU_OPTO ZZ MenuCommand 1 MenuCommand 2 ZZ OTPO_UNEM MENU_OPTO Start key Separator ZZ Start menu Separator Multiple sets allowed Any menu command U2 etc Separator ZZ END menu Separator OTPO_UNEM Stop key 2D menu code can be created at ...

Page 43: ...canner now enters menu mode Scan one or more desired options Multiple menu codes can be read when you want to configure more than one option Read END menu code ZZ All the settings are saved in non volatile memory 1D Menu codes encode an ID consisting of two to five alphanumeric characters 1D Menu codes are Code39 labels with modified start stop characters and therefore the scanner will not acknowl...

Page 44: ... Default setting is the same as the initial setting described in this manual Various interfaces require switching setting Each interface Default Setting 3 2 1 The Active Settings can be returned to the factory default settings Set the command that corresponds to the interface being used Item Command Interface Description Remark Factory Default Settings SU USB HID Restore USB HID to factory default...

Page 45: ... than 30 000 times may destroy memory Avoid saving every time There are options that will not be enabled until Save settings is sent such as baud rate setting Custom Setting 3 2 3 Item Command Description Remark Custom settings BAP Read out Custom Settings BAQ Save to Custom Settings Place BAQ at the end of command packet to be saved To save both Custom settings and Active Settings at same time se...

Page 46: ...e processing of 2D menu codes use the settings below Setting Disable 2D menu codes is recommended when 2D menu codes are not used Item Command Description Default Enable Disable 2D menu code D1Y Enable 2D menu code D1Z Disable 2D menu code Indicates reading 2D menu code as normal 2D code Therefore 2D menu code data will be output when reading success Enable Disable 1D Menu Code 3 3 4 To enable dis...

Page 47: ...rizontal mirrored image configuration Vertical mirrored image E8J Disable vertical mirrored image configuration E8I Enable vertical mirrored image configuration Configuration commands Style Commands Horizontal mirror Vertical mirror Normal image EFU E8J Disable Disable Horizontal mirror image EFV E8J Enable Disable Vertical mirror image EFU E8I Disable Enable 180 rotated image EFV E8I Enable Enabl...

Page 48: ...eration Command only EAU Disable module reading operation Command only Buzzer and Indicator 3 3 7 These commands reflect 4 1 1 Buzzer and 4 1 2 Good Read Buzzer Item Command Description Remark Buzzer B Sound the good read beep Command only E Sound the error beep Status LED L Flash the status LED N Flash the error status LED Reboot the Scanner 3 3 8 Use this command to restart the scanner Item Comm...

Page 49: ...a command requires additional numerical input the commands below can be used Use these in one packet together with the command that requires the numerical input Item Command Description Remark Direct input numerical values Q0 0 Input in a specified format Q1 1 Q2 2 Q3 3 Q4 4 Q5 5 Q6 6 Q7 7 Q8 8 Q9 9 ...

Page 50: ...r 4 Indicator Options NLV 5201 User s Manual 40 1st 4 Indicator Options This chapter describes the options for Buzzer and Good Read LED 4 1 Buzzer 4 2 Status LED 4 3 Good Read Aiming 4 4 Indicator in General ...

Page 51: ...escription Default Buzzer Disable Enable W0 Disable buzzer W8 Enable buzzer Buzzer duration Item Command Description Default Buzzer duration W7 Buzzer duration 50 ms EFW Buzzer duration 75 ms W4 Buzzer duration 100 ms W5 Buzzer duration 200 ms W6 Buzzer duration 400 ms Buzzer tone Item Command Description Default Buzzer tone W1 Middle frequency buzzer 3000 Hz 2600 Hz W2 2 steps buzzer high low buz...

Page 52: ...5 When one code is decoded an intermediate buzzer sounds to indicate that the code is decoded but it does not yet meet the conditions to output data For instance suppose five codes reading is set in buffer mode the intermediate buzzer then sounds after the decoding of the 1st 2nd 3rd and 4th code and a good read buzzer finally sounds when the last code is decoded after which the data is output The...

Page 53: ... Lighting Time 4 2 1 The status LED lights up after a code was successfully decoded and the data was output This can be disabled or set for several durations Item Command Description Default Status LED T4 Disable indicator XT8 Indicator duration 100 ms T5 Indicator duration 200 ms T6 Indicator duration 400 ms T7 Indicator duration 800 ms ...

Page 54: ...ption Default Good Read Aiming EF3 Qa Qb Qc a Setting items 0 Indicator frequency 1 First indicator duration after reading b Numerical setting 10b c Indicator frequency 00 99 times Indicator duration 00 99 x10 ms Indicator frequency 0 time Indicator duration 50 ms c Setting example Lights 2 times After 100 ms Default Command EF3Q0Q0Q2 Set first indicator duration after reading to 500 ms Continue t...

Page 55: ...tings for each indicator are described below Indicator Timing 4 4 1 The indicators can be activated after decoding a code and before or after transmitting the data Item Command Description Default Remark Indicator timing VY Before data transmission soon after decoding VZ After data transmission ...

Page 56: ...Interface NLV 5201 User s Manual 46 1st 5 Interface The scanner support RS 232C USB COM and USB HID interface This chapter explains each interface in detail 5 1 RS 232C 5 2 USB HID 5 3 USB COM 5 4 Common Settings ...

Page 57: ...1st RS 232C 5 1 This chapter explains RS 232C interface settings 5 1 1 RS 232C Basic Information 5 1 2 Baud Rate Transfer Speed 5 1 3 Character Format 5 1 4 Handshaking Flow Control 5 1 5 Inter Character Delay RS 232C 5 1 6 Trouble Shooting RS 232C ...

Page 58: ...elay Baud Rate Transfer Speed 5 1 2 The baud rate is the rate at which bits are transmitted from the scanner to the host and vice versa Both the scanner and the host must be set to the same baud rate The following commands can be used to configure the baud rate Z2 safe settings in non volatile memory needs be used after these commands to activate and save the new configuration Item Command Descrip...

Page 59: ... these commands to activate and save the new configuration Item Command Description Default Remark Data bit L0 7 data bits Enabled after sending Z2 L1 8 data bits Parity bit L2 No parity L3 Even parity L4 Odd parity Stop bit L5 1 stop bit L6 2 stop bits Handshaking Flow Control 5 1 4 The communication control method can be set using these commands Z2 save command in non volatile memory needs be us...

Page 60: ...n so ready to receive data except during the processing of received data while transmitting data and while it is busy processing 1D 2D menu codes When the scanner wants to send data it first will check if its CTS line is on to be sure that the host is ready to receive data If the CTS line is off the scanner does not send the data but waits for a specific timeout period for the CTS line to be tuned...

Page 61: ...I1 Flow Control timeout 100 ms I2 Flow Control timeout 200 ms I3 Flow Control timeout 400 ms C MODEM The scanner s RTS is OFF as soon as power is supplied to the scanner The scanner will turn RTS ON when it wants to transmit data to the host The host should respond with CTS ON when it is ready to receive data While the host CTS is ON the scanner is allowed to transmit data When all data has been t...

Page 62: ...II 0x11 The scanner terminates transmission without the good read or error buzzer Timeout If there is no response within 1second the scanner terminates transmission with the error buzzer ACK NAK Flow chart BUZERn RxD TxD Scanner Host System RxD TxD Decode Finish Send ACK Wait Buzzer ACK LabelA LabelB LabelB Read Processing Start of transmission Transmit data Start 1 sec timer As configured Respons...

Page 63: ...a has been received correctly by the host Response ACK ASCII 0x06 The scanner terminates transmission with the good read buzzer Response NAK ASCII 0x15 The scanner sends the data again Response DC1 ASCII 0x11 The scanner terminates transmission without a good read or error buzzer Timeout If there is no response within 100 ms then the scanner terminates transmission with the good read buzzer ACK NA...

Page 64: ...6 Following are the several countermeasures for the trouble caused by RS 232C Behavior Check points Countermeasures Cannot communicate No response when sending command Confirm communication settings 5 1 2 transfer speed 5 1 3 character format etc After changing communication setting send Z2 command Most of communication settings are not reflected until Z2 command is sent Confirm 5 1 4 handshake se...

Page 65: ... chapter explains USB HID interface settings 5 2 1 USB HID Basic Information 5 2 2 Connection Confirmation USB HID 5 2 3 NumLock CapsLock control 5 2 4 Data Output Speed USB HID 5 2 5 Inter Character Delay USB HID 5 2 6 Keyboard Language 5 2 7 Trouble Shooting USB HID ...

Page 66: ...e No control Data transmit speed Use when outputting data with high speed Initial setting 4 ms Setting range 1 ms 16 ms Data transmit interval Inter character delay Use when data is missing Initial value no interval Suspend mode Remote wakeup Use when host system is using suspend Initial value Valid Keyboard language Set according to the keyboard language Initial value English USA Character code S...

Page 67: ...control 5 2 3 Set NumLock and CapsLock control method when sending data Item Command Command description Initial setting Notes NumLock control RN Numeric value does not use numeric keypad RM Numeric value use numeric keypad A Follow NumLock status 1 CapsLock control 5Q No control 8A Invert CapsLock status 2 2U CapsLock automatic control 3 1 Only use numeric keypad when NumLock is ON 2 When startin...

Page 68: ...nsfer interval Interval 10a b ms Unit 4 ms 1 16 ms Setting example Set the transmit interval to 1 ms fastest Command E9MQ1 Set the transmit interval to 10 ms Command E9MQ1Q0 Inter Character Delay USB HID 5 2 5 The inter character delay introduces a configurable delay after each transmitted character This may be used if the host does not support flow control and is not capable of handling the recei...

Page 69: ...erman Windows 1252 KI French Windows 1252 OW Italian Windows 1252 KJ Spanish Windows 1252 PH Portuguese Windows 1252 PL Swiss French Windows 1252 PK Swiss German Windows 1252 PI Dutch Windows 1252 PJ Belgian Windows 1252 PD Swedish Windows 1252 PG Finnish Windows 1252 KK Danish Windows 1252 PE Norwegian Windows 1252 WF Czech Windows 1250 BAY Hungarian Windows 1250 BPJ Turkish Windows 1254 EF4 Russ...

Page 70: ... WIME with USB COM Refer to 5 3 6 Line break is doubled Set the suffix additional setting according to the host side application s line break Cannot output images Cannot transfer images The scanner does not appear in Device Manager Restart unexpectedly Error beep sounds and does not output by reading Check that USB cable is properly connected Ensure that connected USB port is operating properly Co...

Page 71: ...M 5 3 This chapter explains USB COM interface settings 5 3 1 USB COM Basic Information 5 3 2 Integration USB driver 5 3 3 Connection Confirmation USB COM 5 3 4 Fixed UBS COM Port 5 3 5 Connection Method 5 3 6 COM to HID Output 5 3 7 Trouble Shooting USB COM ...

Page 72: ...ber Fixing COM number is possible Default not fix Integration USB driver 5 3 2 USB driver is required to connect to the PC via USB COM interface Please download the USB driver from our website and install appropriately according to the attached documents Connection Confirm 5 3 3 USB COM interface confirm the connection by following procedure For Windows 10 Install Opticon USB driver 1 Connect the ...

Page 73: ...n Method 5 3 5 Connect to the host PC by following procedure 1 Start the tool to serial communicates emulator or UniversalConfig 2 Connect to the COM port confirmed at 5 3 3 Connection 3 For Command packet refer to 3 1 1 COM to HID Output 5 3 6 WIME Windows NET Application allows to convert data received by the scanner via virtual COM port USB COM to HID like and transfer to the application which ...

Page 74: ...ng laptop or hub supply capacity may insufficient Remove from the USB port at once and after a while insert again Insert to different port Error beep sounds and does not output by reading In addition to above Open the COM port with the communication tool Cannot connect Cannot open COM port Confirm the COM port number by device manager Refer to 5 3 3 for how to check Close the tool and re open it O...

Page 75: ...h as barcode scanning while outputting decoded data However the reading performance may degrade during the data output When buffer mode is disabled the scanner stops other operations until the completion of decoded data output The following menu codes commands are provided for the data buffer mode setting Item Command Description Default Data buffer mode D80 Data buffer disable D81 Data buffer ena...

Page 76: ...Chapter 6 Reading and Timing NLV 5201 User s Manual 66 1st 6 Reading and Timing This chapter describes the read timing and various timings of the scanner 6 1 Reading and Trigger Control 6 2 OK NG Signal ...

Page 77: ...code Timeout t3 When decoding successes transfer the data Refer to Baud Rate t4 OK signal when decoding success NG signal when reading time out Refer to OK NG Signal t5 When decoding successes green LED on the side panel of housing lights Refer to Status LED t6 When decoding success the buzzer sounds Refer to Buzzer t7 When decoding success aiming can be turned on Refer to Good Read Aiming t4 OK N...

Page 78: ...the default read time refer to Read Time is invalid the read time with the Z command will be Indefinitely and reading will stop by Y command When reading with a command start reading by trigger Z command and stop reading by sending Y command etc When effective read time is set it stops reading when the set time elapses Also it stops when sending Y commands etc Z Command Y Command Scan time Command...

Page 79: ...start timing when effective read time refer to 6 1 4 is set can be set as follows Item Command Description Default Effective read time start timing O Start from TRIGn signal end P Start from TRIGn signal start Start from trigger signal end Start from trigger signal start When external trigger signal is not used and if there is a possibility of noise generation disable the signal Item Command Descr...

Page 80: ...seconds Y3 3 seconds Y4 4 seconds Y5 5 seconds Y6 6 seconds Y7 7 seconds Y8 8 seconds Y9 9 seconds YL Read time infinite YM Read time 10 times When auto trigger with Y0 read time is automatically set by the image processing The extended read time can be set with numerical parameters by inputting the command followed by a 4 digit numerical command in unit of 10 ms Item Command Description Default e...

Page 81: ...rom after the trigger delay set time to trigger Item Command Description Default Trigger delay DEC Qa Qb Qc Qd Trigger delay time 1000a 100b 10c 1d x 10ms 0 ms The timing diagram of the trigger delay is as below Data Trigger signal Command Scan Trigger delay Trigger delay time Data Z Command Imaging and Decoding ...

Page 82: ...eout can limit decode processing time for 1 image Item Command Description Default Decode timeout EAV Q7 Q4 Qa Qb Qc Qc Trigger delay time 1000a 100b 10c 1d x 10ms 0 ms Decode timeout 0 means function is disabled Process decoding for 1 image until the end Processing time depend on the image ...

Page 83: ...able Disable OK NG signal 6 2 1 To enable disable use the settings below Item Command Description Default Enable Disable OK NG signal X Q Enable OK NG signal X R Disable OK NG signal The basic flow chart is shown below OK NG Signal Enable End Disable Enable OK signal active Clear OK NG signal Inactive Reading successes Successes Reading start OK NG Signal Enable Fail NG signal active Enable Disabl...

Page 84: ...nal is HIGH active the time to hold active state with One Shot is T For SYNC synchronize OK or NG signal becomes active after reading is completed and the active state is hold until next reading starts For One Shot becomes active when reading is complete and becomes inactive after time T When the next reading starts before time T passes becomes inactive in between To set time T to hold One Shot ac...

Page 85: ...uning and Bank Function NLV 5201 User s Manual 75 1st 7 Tuning and Bank Function This chapter describes the tuning and bank function of the scanner 7 1 Tuning Overview 7 2 Tuning 7 3 Reading Test 7 4 Bank Function ...

Page 86: ...imum exposure for the code to be read and limits the effective read code Also you can find the optimum installation condition by using UniversalTuningTool By using the tuning function and adjusting the exposure range the user can improve performance of the scanner for scan in motion applications Please contact sales offices for the tools ...

Page 87: ...nned Media and Placement Perform tuning Tuning Perform a test and confirm whether it is a stable reading Reading Test Examine require setting for operation Refer to each section Integration Set the scanner in the following order Configure settings that are required in advance like interface setting etc Interface Configure require setting for operation Refer to each section Perform tuning Caution E...

Page 88: ...dle of tuning 2 1 Tuning complete will be output when tuning successes and after line brake separate each output items with at tuning Tuning complete CR Indicate tuning success and line brake BANK 1 CODETYPE QRCode SHUTTER 177 us GAIN 648 RATE 100 TIME 25 26 ms 123456789 CR Bank No Code Type Shutter Speed Sensor Gain Read rate in 10 times Min Max of read times in 10 times Read Data Line Break 2 Th...

Page 89: ...time Adjustment lower limit value us 0 0 Set to d ef x 10 c us From 30μs Shutter time Adjustment upper limit value us 0 1 To 9000μs Sensor gain Adjustment lower limit value times 1 0 Set to cd ef times From 1 time Sensor gain Adjustment upper limit value times 1 1 To 10 times Setting example Set adjustment upper limit value of shutter time to 400 μs Esc DT3Q0Q1Q2Q4Q0Q0 CR To output current exposur...

Page 90: ...h And output this continuously To start end reading test use the following command Item Command Description Remark Reading test Start End V Start reading test W End reading test The reading test outputs following data continuously BANK 1 RATE 100 TIME 25 26 ms 123456789 CR BANK 1 RATE 100 TIME 24 28 ms 123456789 CR BANK 1 RATE 100 TIME 24 27 ms 123456789 CR BANK 1 RATE 100 TIME 24 26 ms 123456789 ...

Page 91: ...ank selection and trigger Z command This allows executing with 1 command Item Command Description Default Bank selection TRG Qa Qb Bank specify trigger Effective value a 0 b 1 7 a 0 b 1 To end reading use Y command just like Z command Confirm Current Bank 7 4 3 To confirm current bank number use the following setting Item Command Description Remark Confirm current bank DGQ Display the current bank...

Page 92: ...Chapter 8 Read Options NLV 5201 User s Manual 82 1st 8 Read Options This chapter describes the read options for the scanner 8 1 Read Modes Overview 8 2 Auto Trigger 8 3 Illumination and Aiming ...

Page 93: ... key on the side of scanner to operate when testing and maintenance Trigger Delay Time Trigger delay Delay read operation until specified time Default no delay Read Mode Single read End after reading 1 code Default Multiple read 1 Stores read code data to memory and continue operation with not reading the same data Multiple read 2 Permit same data reading of read code data with time limit and cont...

Page 94: ...cessfully decoded until the read time expires To prevent that a barcode is read twice the scanner saves the read barcodes in memory and checks if it has been read before The list in memory is 20 barcodes long so after 20 different barcodes the same barcode can be read again If there is more than one code within the read area as in the following figure this read mode is helpful to prevent reading t...

Page 95: ...rcode is read in between or when at least Double read reset time refer to 8 2 3 has past If the same code continues to be at the same position in the image it will not be read even if the double read reset time has canceled Example Read multiple codes sequentially with single trigger Double read reset time Double read reset time Continues Read To confirm the reading performance in test etc read co...

Page 96: ...ode in a batch setting is available from the UniversalConfig batch reading function From following table up to 4 codes batch reading can be set Please contact to sales offices if there are items cannot be set with above Data Edit Function 8 1 4 Data edit script programming is a form of data output formatting so the user may change the scanned data to a format that is more desirable to be output Th...

Page 97: ...he detection sensitivity can be adjusted The sensitivity varies with the ambient environment and adjustment may be necessary Item Command Description Default Auto trigger sensitivity XMF Sensitive XMH Normal XMJ Insensitive Double Read Reset Time 8 2 3 This allows setting of time interval before the same code can be decoded again in auto trigger mode When a code with different data is read this wi...

Page 98: ...de 8 2 5 When nothing is detected after a specific configurable period while in auto trigger mode the scanner goes into sleep mode The scanner performs presence detection at specified time intervals in sleep mode and when a target is detected or any event such as trigger occurs the unit exits from sleep mode Setting a time of 0 seconds means that sleep mode is disabled Item Command Description Def...

Page 99: ...on in which a code was read is memorized and will be prioritized for subsequent reading This function is recommended when reading the target that specular reflection easily occurs LED Illumination Prevent specular reflection Disable illumination only when specular reflection by LED illumination occur and reads Item Command Description Default LED illumination mode D39 LED illumination Enable D3A L...

Page 100: ...specific options and number of characters to be read It is strongly recommended to enable only the required codes and options for best reading performance These settings do not affect the reading of the 1D menu codes Refer 11 3 Sample codes for the codes 9 1 Setting of Readable Codes 9 2 Setting of Code Common Options 9 3 Setting of Code Specific Option 9 4 Setting of Number of Characters ...

Page 101: ...mbologies Enable Disable command Default Single Multiple Disable Enable Mini length Positive Negative Image ST SP trans mission CD check Suffix UPC J1 R1 X4B Positive Image Only USB HID ENTER USB COM RS 232C CR UPC A J1A R1A V1A UPC E J1B R1B V1B EAN JAN J4 R4 X4E EAN JAN 13 JG JU DDM EAN JAN 8 JA JO DDN Code 39 A2 B2 VB 1 Tri Optic JD JZ DDJ Codabar A3 B3 VC 2 Industrial 2 of 5 J7 R7 X4K 5 Interl...

Page 102: ...le Suffix Chinese Post Matrix 2 of 5 JE JS JT USB HID ENTER USB COM RS 232C CR Korean Postal Authority JL WH WI Intelligent Mail Barcode D5H D5F D5G POSTNET D6C D6A D6B PLANET DG2 DG3 DG4 Japan Postal D5R D5P D5Q Netherland KIX Code D5M D5K D5L Australian Postal D6O D6M D6N UK Postal Royal mail DG7 DG8 DG9 4 State Mailmark Barcode DGS DGT DGU ...

Page 103: ...xpanded GS1 DataBar Expanded Stacked JK DR SL Refer to 9 2 1 for convert GS1 and read GS1 Composite Code 9 1 4 Symbologies Enable Disable command Default Multiple Disable Enable Suffix Composite GS1 DataBar CC A CC B Limited CC A Limited CC B Expanded CC A Expanded CC B BHE BHF USB HID ENTER USB COM RS 232C CR Composite GS1 128 CC A CC B CC C Composite EAN EAN 13 CC A EAN 13 CC B EAN 8 CC A EAN 8 ...

Page 104: ...es BF4 BF2 BF3 Chinese sensible code D4K D4L D4M Maxi Code BC2 BCE BCQ Refer to 9 2 1 for convert and read GS1 QR code and GS1 Data Matrix Other Options for Codes 9 1 6 Symbologies Single Multiple Disable Remark All codes 1D 2D A0 B0 Excluding add on All 1D codes BCA BCM BCY Excluding add on All 2D codes BCB BCN BCZ 1 2 1 PDF417 Codablock F QR Code Data Matrix ECC 200 Maxi Code MicroPDF417 Aztec C...

Page 105: ...ENTER USB COM RS 232C CR Machine readable Visa A DJ4 DJ5 DJ6 Machine readable Visa B DJ7 DJ8 DJ9 Official Travel Documents 1 DJA DJB DJC Official Travel Documents 2 DJD DJE DJF ICAO travel document can be read regardless of the image direction because the format is fixed OCR free edit To free edit standard OCR font and read refer to 9 2 6 OCR free edit For advanced setting please check the separat...

Page 106: ...utted Initial setting status FNC1 Non output AI Data Fixed length AI Data Variable length FNC1 Non output AI AI Data Variable length GS1 after conversion For USB HID AIM ID output AI Data Fixed length AI Data Variable length Ctrl Key output AI AI Data Variable length For USB COM and RS 232C AIM ID output AI Data Fixed length AI Data Variable length GS 0x1D Output AI AI Data Variable length For AIM...

Page 107: ...e and white on black background is called negative barcode Positive Image of Code 128 Negative Image of Code 128 Following are the positive and negative barcode reading setting Code Item Command Description Default 1D Positive and Negative Image of Barcodes DLA Q0 Decode positive bar codes only Q1 Decode negative bar codes only Q2 Decode positive bar codes and negative bar codes It is strongly rec...

Page 108: ...cy 3 BS Read 5 time redundancy 4 BT Read 6 time redundancy 5 BU Read 7 time redundancy 6 BV Read 8 time redundancy 7 BW Read 9 time redundancy 8 This setting only affects the reading of 1D barcodes 2D codes are not affected by this redundancy setting Add on waiting time 9 2 4 The scanner search valid UPC EAN add on code within the selected time If effective add on code is found scanner sends data ...

Page 109: ...er following the back slack and 2 back lash indicates back slash To not to output ECI protocol change the data career identifier to ID not using ECI protocol delete the 6 digits number following the back slash and replace the 2 back slashes to 1 back slash Supported Code QR Code Data Matrix Aztec Code Maxi Code Output example Output Q2 000001test test Not output Q1test test Back slash Setting comm...

Page 110: ... OCR standard format set from UniversalConfig OCR free edit function Numerical value alphabet symbol of up to 40 digits and 2 rows can be set For advanced setting please check the separate sheet Data Edit Programing Manual Please contact to the sales offices for the items cannot set ...

Page 111: ... UPC A Add on 2 digits 5 digits UPC A add on 2 digits 5 digits is a barcode of UPC A plus 2 digits or 5 digits supplement code When Add on is enabled 2D scanner needs Add on code to be within the read range or fails to read If it is not within the range after Add on waiting time it reads as UPC or EAN When Add on is enabled and reading only UPC EAN reading response will decrease Transfer data form...

Page 112: ...ts is a barcode of UPC E plus 2 digits or 5 digits supplement code Transfer data format UPC E Add on 2 digits Leading 0 Data 6 digits CD 1 digit Add on 2 digits Transfer data format UPC E Add on 5 digits Leading 0 Data 6 digits CD 1 digit Add on 5 digits UPC E CD transfer front 0 transfer This allows you to set whether or not to transmit CD check digit and a leading 0 The 8 digits transfer data fo...

Page 113: ...single UPC Add on 2 R2 Enable UPC Add on 2 X4C Disable UPC Add on 2 Add on 5 digits J3 Enable single UPC Add on 5 R3 Enable UPC Add on 5 X4D Disable UPC Add on 5 UPC E UPC E Leading zero CD transmission E6 UPC E Leading zero transmit CD transfer digits 8 digits E7 UPC E No leading zero transmit CD transfer digits 7 digits E8 UPC E Leading zero not transmit CD transfer digits 7 digits E9 UPC E No l...

Page 114: ...it Setting items EAN JAN 13 Add on 2 digits 5 digits EAN JAN 13 Add on 2 digits 5 digits is the barcode of EAN JAN 13 plus 2 digits or 5 digits supplement code When Add on is enabled 2D scanner needs Add on code to be within the read range or fails to read If it is not within the range after Add on waiting time it reads as UPC or EAN When Add on is enabled and reading only UPC EAN reading response...

Page 115: ... conversion of EAN 13 9791230671184 converts it to 1230671188 and outputs it ISBN conversion of EAN 13 9780123782830 converts it to 012378283X and outputs it ISSN conversion When ISSN conversion is enabled it converts data with a leading 977 of EAN 13 ISSN conversion will re calculate CD by omitting leading 3 digits and outputs it in 8 digits ISMN conversion When ISMN conversion is enabled it conv...

Page 116: ...AN 8 plus 2 digits or 5 digits supplement code When Add on is enabled 2D scanner needs Add on code to be within the read range or fails to read If it is not within the range after Add on waiting time it reads as UPC or EAN When Add on is permitted and reading only UPC EAN reading response will decrease Transfer data format EAN JAN 8 Add on 2digits Data 7 digits CD 1 digit Add on 2 digits Transfer ...

Page 117: ...9 414 419 977 978 Enable EAN forced add on D When EAN 13 start at 434 439 414 419 977 978 Disable EAN forced add on ISBN Conversion IB Disable ISBN conversion IA Enable ISBN conversion IK When possible enable ISBN conversion ISSN Conversion HN Disable ISSN conversion HO Enable ISSN conversion 4V When possible enable ISSN conversion ISMN Conversion IO Disable ISMN conversion IP Enable ISMN conversi...

Page 118: ...ion Settings Standard Code39 Send data character as it is Full ASCII Code39 This setting converts the correct combination of the data character to Full ASCII and transmits it If an incorrect combination is found in the character it will not be transmitted When possible Full ASCII Code39 This setting converts the specified combination of the data character to Full ASCII and transmits it Incorrect c...

Page 119: ...ion D9 Transmit Code39 CD D8 Not transmit Code39 CD ST SP transmission D1 Not transmit ST SP D0 Transmit ST SP Full ASCII conversion D5 Normal Code 39 D4 Full ASCII Code 39 K Full ASCII Code 39 if possible It Pharm D6 It Pharmaceutical only D7 It Pharmaceutical if possible DA Not transmit leading A for It Pharm DB Transmit leading A for It Pharm Concatenation M Disable concatenation L Enable conca...

Page 120: ...de ABC is an acronym of American Blood Commission It consists of 2 side by side barcodes Margin is necessary When the barcode s first stop character and the second start character is D it will be concatenated and sent Two D character will not be sent CX mode It consists of 2 side by side barcodes Margin is necessary When the barcode s first stop character is C and the second start character is B i...

Page 121: ...it Codabar CD ST SP transmission F0 Not transmit Start Stop code F1 Start Stop code ABCD TN E F2 Start Stop code abcd tn e F3 Start Stop code ABCD ABCD F4 Start Stop code abcd abcd HJ Start Stop code DC1 DC2 DC3 DC4 DC1 DC2 DC3 DC4 Space insertion HE Disable space insertion HD Enable space insertion ABC CX conversion HA Enable only Codabar normal mode H4 Enable only ABC code H5 Enable only CX code...

Page 122: ...5 S Code and Matrix 2 of 5 CD check or not Interleaved 2 of 5 CD transmit Whether to transfer CD check digit or not is configurable This setting also configures Interleaved 2 of 5 Industrial 2 of 5 S Code and Matrix 2 of 5 CD transfer or not Industrial 2 of 5 space check Whether to enable disable the space inter character gap check of Industrial 2 of 5 which has large or irregular spaces can be se...

Page 123: ...or setting detail Concatenation of Code 128 When Code128 data s leading is FNC2 character concatenate or not can be set Reading the barcode that contains FNC2 character in leading of Code128 data concatenate the data by omitting the leading FNC2 When reading the barcode that does not contains FNC2 character in leading of Code128 it concatenates the data to the end of data that is buffering to the ...

Page 124: ... 10 4C Check 2 CD MOD 10 MOD 10 4D Check 2 CD MOD 10 MOD 11 4R Check 2 CD MOD 11 MOD 10 4S Check 2 CD MOD 11 MOD 11 CD transmission 4G Not transmit CD 4E Transmit CD 1 4F Transmit CD 1 and CD 2 UK Plessey 9 3 9 Code Item Command Description Default UK Plessey CD transmission 4O Not transmit CD 4N Transmit CD Space insertion DO Disable space insertion DN Enable space insertion X conversion DP Conve...

Page 125: ...LH Check 2CD BLI Check auto 1 or 2 CD CD transmission BLJ Not transmit CD BLK CD transmit Korean Postal Authority 9 3 12 Code Item Command Description Default Korean Postal Authority code CD transmission CD transmit Not transmit CD Transmit dash Transmit dash Not transmit dash Upside down reading 9 Upside down reading enabled 8 Upside down reading disabled ...

Page 126: ...et numbers 20 types symbol function character FNC1 Digits GS1 DataBar Omnidirectional and GS1 DataBar Limited Application identifier 01 and 14 digits GS1 DataBar Expanded number 74 digits and alphabet 41 digits Check sum Check sum is always checked but not sent GS1 DataBar Omnidirectional Modulus 79 GS1 DataBar Limited Modulus 89 GS1 DataBar Expanded Modulus 211 CD check GS1 DataBar Omnidirectiona...

Page 127: ... B is normal MicroPDF417 CC C is normal PDF417 Maximum digits CC A 56 character CC B 338 character CC C 2361 character Symbol size 1D part refer to GS1 DataBar and UPC EAN Composite part CC A and CC B are same as MicroPDF417 CC C is same as PDF417 Error correction 1D part error detection only Composite par Reed Solomon error correction Link flags GS1 DataBar and GS1 128 composite have link flags U...

Page 128: ...um digits PDF417 Text compression 1850 character Byte compression 1108 character Numeric compression 2710 character Maximum digits MicroPDF417 Text compression 250 character Byte compression 150 character Numeric compression 366 character Symbol size PDF417 Number of lines 3 90 Number of rows 1 30 Symbol size MicroPDF417 Number of lines 4 44 Number of rows 1 4 Error correction PDF417 Error correct...

Page 129: ...Chinese character Character specified by the shift coded expression of JIS X 0208 Maximum digits Alphanumeric data 4296 character 8 bit data 2953 character Numeric data 7089 character Chinese character data 1817 character Symbol size Minimum 21 x 21 module Maximum 177 x 177 module Error correction Reed Solomon error correction level 4 L 7 M 15 Q 25 H 30 Negative barcode mirror printing Negative an...

Page 130: ...the shift coded expression of JIS X 0208 Maximum digits Alphanumeric data 21 character 8 bit data 15 character Numeric data 35 character Chinese character data 9 character Symbol size error correction Version M1 11 x 11 module Error detection only Version M2 13 x 13 module Reed Solomon error correction 2 steps L M Version M3 15 x 15 module Reed Solomon error correction 2 steps L M Version M4 17 x ...

Page 131: ...gits ECC200 square Alphanumeric data 2335 characters 8 bit data 1556 characters Numeric data 3116 characters Maximum digits ECC200 rectangle Alphanumeric data 98 characters 8 bit data 47 characters Numeric data 72 characters Symbol size ECC200 Even rows and even columns square or rectangle Square minimum 10 x 10 maximum 144 x 144 module Rectangle minimum 8 x 18 maximum 16 x 48 module 6 patterns Er...

Page 132: ... ASCII value 0 127 ISO 646 ASCII value 128 255 ISO 8859 1 Alphabet No 1 Expand ASCII Using ECI many other character sets Maximum number of digits Alphanumeric data 3067 characters Number 3832 characters Byte 1914 character Symbol size Minimum 15 x 15 module Maximum 151 x 151 module Error correction The selectable error correction level is 5 to 95 of the data area Transfer data format Data variable...

Page 133: ... Fixed Length ON Minimum Maximum Length for Selected Codes 9 4 1 This option enables fixed length and minimum maximum length checking for each code types and will only affect the specified code types Configuration with commands Item Command Description Default valid range Fixed length Specify Code Input length of digits Fixed length for selected codes Length 1000a 100b 10c d 0 8000 9 4 2 Qa Qb Qc ...

Page 134: ...abar DC2 DB2 DA2 Industrial 2 of 5 DC3 DB3 DA3 Interleaved 2 of 5 DC4 DB4 DA4 Code 93 DCD DBD DAD Code 128 DCB DBB DAB MSI Plessey DC8 DB8 DA8 IATA DC7 DB7 DA7 PDF417 DCL DBL DAL QR code DCJ DBJ DAJ Data Matrix DCH DBH DAH Maxi code DCK DBK DAK Aztec code DCI DBI DAI MicroPDF417 DCM DBM DAM RSS Expanded GS1 Databar DCF DBF DAF Composite DCG DBG DAG GS1 128 DCC DBC DAC S Code DC5 DB5 DA5 UK Plessey...

Page 135: ... Options NLV 5201 User s Manual 125 1st 10 String Options This chapter describes the alterations which can be made to the transmitted data string The configurations available are 10 1 Prefix Suffix 10 2 Case Conversion ...

Page 136: ...be added in front of or at the end of the data for each specific symbology 1 By default the prefix is empty and the suffix of all codes is a CR character When using 9 2 6 OCR Free Edit or 8 1 4 Data Edit Function this cannot be set Preamble Postamble up to 8 digits Specified characters can be added in front of or at the end of the data for all codes By default they are empty Preamble Prefix for ea...

Page 137: ...dentification The code identification is transmitted in OPTICON ID ISO15424 standard or AIM ID Code length The code length is the number of characters after the output format that is configured with options in 9 3 Setting of Code Specific Options Scan time The scan time is the time from the trigger until the data output start ...

Page 138: ... time 10 1 8 Example to set C39 as the prefix and CR and LF as the suffix for Code 39 Command Esc M40CQ3Q96AO41M1J CR Prefix Suffix can also be set with menu barcode or 2D menu code Note The prefix and suffix setting commands clear the current values and configure new ones The default suffix of CR is also cleared Clearing the default suffix CR is possible by scanning the RZ menu code Set suffix fo...

Page 139: ...ode prefix suffix setting command Code Prefix Command Suffix Command UPC A N1 N6 UPC A add on M0 O0 UPC E N2 N7 UPC E add on M1 O1 EAN 13 N3 N8 EAN 13 add on M2 O2 EAN 8 N4 N9 EAN 8 add on M3 O3 Code 39 M4 O4 Tri optic MC PN Codabar M5 O5 Industrial 2 of 5 M6 O6 Interleaved 2 of 5 M7 O7 S Code MB OB Matrix 2 of 5 GL GM Chinese Post Matrix 2 of 5 IATA I8 I9 MSI Plessey N0 N5 Telepen L8 L9 UK Plesse...

Page 140: ...G GS1 DataBar Limited D6K D6H GS1 DataBar Expanded D6L D6I GS1 Composite code RR RS Codablock F D4S D4T Data Matrix MD PO Aztec BF0 BF1 Chinese Sensible Code D4N D4O QR Code MK PW Maxi Code ML PX PDF417 OC PY MicroPDF417 OD PZ Machine Readable Passports DJJ DJP Machine Readable Visas A DJK DJQ Machine Readable Visas B DJL DJR Official Travel Documents 1 DJM DJS Official Travel Documents 2 DJN DJT ...

Page 141: ...H G BEL 1G 5I I 0I i I H BS 1H 5J J 0J j J I HT 1I 5K K 0K k K J LF 1J 5L L 0L l L K VT 1K 5M M 0M m M L FF 1L 5N N 0N n N M CR 1M 5O O 0O o O N SO 1N 5P P 0P p P O SI 1O 6A Q 0Q q Q P DLE 1P 6B R 0R r R Q DC1 1Q 6C S 0S s S R DC2 1R 6D T 0T t T S DC3 1S 6E U 0U u U T DC4 1T 6F V 0V v V U NAK 1U 6G W 0W w W V SYN 1V 7A X 0X x X W ETB 1W 7B Y 0Y y Y X CAN 1X 7C Z 0Z z Z Y EM 1Y 7D 0 Q0 Z SUB 1Z _ 7...

Page 142: ...ter Example Add OPTICON Code ID to the all codes prefix Configuring with Command Esc RY 2 CR Code Length 10 1 6 For 1D codes the code length is transmitted as 2 digits excluding prefix and suffix characters For 2D codes the code length is transmitted as 6 digits It is also possible to send the length as 6 digits for both 1D and 2D codes These direct input characters count as 1 entry of the 4 permi...

Page 143: ...code within the image Item Command Description Default Code Coordinates DDX Code vertex coordinate DDY Code center coordinate Vertexes output format X1 Y1 X2 Y2 X3 Y3 X4 Y4 Center output format X Y X Y format X 1 to 3 digits Y 1 to 3 digits The range of coordinate is described below X 0 to 639 Y 0 to 479 Coordinate 0 0 Vertex1 X1 Y1 Center X Y Vertex2 X2 Y2 Vertex3 X3 Y3 Vertex4 X4 Y4 X Coordinate...

Page 144: ...User s Manual 134 1st Scan Time 10 1 8 The scan time is the time from trigger until data output start Item Command Description Default Scan time value EDG Scan time Data Data Trigger Command Scan Imaging and Decoding Scan time Z Command ...

Page 145: ...he host requires upper or lower case characters only Upper case Lower case conversion example Description AbCd Default No case conversion AbCd Convert to upper case ABCD Convert to lower case abcd Exchange case aBcD Upper case and Lower case can be set from following commands Items Command Description Default Case Conversion YZ No case conversion YW Convert to upper case YX Convert to lower case Y...

Page 146: ...Chapter 11 Appendix NLV 5201 User s Manual 136 1st 11 Appendix This chapter lists the reference data 11 1 Code ID Table 11 2 NLV 5201 Specification Overview 11 3 Sample Codes ...

Page 147: ...gent mail 0 EAN 8 A Postal TNT KIX 1 EAN 8 2 J Japan postal 2 EAN 8 5 K Postnet 3 Code 39 V Australia postal code 4 Code 39 Full ASCII W US Planet 6 Italian Pharmaceutical Y UK Postal Royal mail 7 Codabar R 4 state Mailmark barcode 8 Codabar ABC S Codablock F E Codabar CX f Data Matrix t Industrial 2 of 5 O Aztec o Interleaved 2 of 5 N Aztec Runes S Code g Chinese Sensible Code e Matrix 2 of 5 Q Q...

Page 148: ...igent Mail Barcode X0 EAN 8 E4 POSTNET X0 EAN 8 2 E7 GS1 DataBar e0 EAN 8 5 E7 CC A e1 Code 39 A CC B e1 Code 39 Full ASCII A CC C e1 Tri Optic X0 GS1 DataBar with CC A e0 Code 39 lt Pharmaceutical X0 GS1 DataBar with CC B e0 Codabar F GS1 DataBar with CC C e0 Codabar ABC F Codablock F O Codabar CX X0 DataMatrix d Industrial 2 of 5 S0 Aztec z Interleaved 2 of 5 I X0 S Code X0 QR Code Q Matrix 2 of...

Page 149: ...t transmit CD D8 A3 Full ASCII Code 39 D4 or Full ASCII Code 39 if pos K Check CD C0 Not transmit CD D8 A7 Codabar option AIM ISO15424 Code ID F Codabar normal mode HA Not check CD H7 Transmit CD H8 F0 Codabar normal mode HA Not check CD H7 Not transmit CD H9 F4 Codabar ABC H4 or H3 Not check CD H7 Transmit CD H8 F1 Codabar ABC H4 or H3 Not check CD H7 Not transmit CD H9 F5 Codabar normal mode HA ...

Page 150: ...D 10 MOD 10 4C 4C Transmit CD1 4E or 4C Not transmit CD 4G or 4C Transmit CD1 and CD2 4F X0 Check 2CD s MOD 11 MOD 10 4R 4D Transmit CD1 4E or 4D Not transmit CD 4G or 4D Transmit CD1 and CD2 4F X0 Telepen option AIM ISO15424 Code ID B Telepen numeric or ASCII only Telepen numeric followed by ASCII ASCII mode D3 B0 ASCII mode D3 B0 Numeric mode D2 B1 Numeric mode D2 B2 Telepen ASCII followed by nu...

Page 151: ... z4 Structured append header included FNC1 preceding 1st message character ECI protocol implemented zA FNC1 following an initial letter or pair of digits ECI protocol implemented z5 Structured append header included FNC1 following an initial letter or pair of digits ECI protocol implemented zB Structured append header included z6 Structured append header included and FNC1 preceding 1st message cha...

Page 152: ...ED Aiming light source Single line green LED Effective pixels 0 30 million pixels H 640 x V 480 View angle Horizontal about 38 0 Vertical about 28 9 Diagonal about 46 4 Supported 1D Symbologies Symbologies 1D UPC A UPC E UPC A Add on UPC E Add on EAN 13 EAN 8 EAN 13 Add on EAN 8 Add on JAN 13 JAN 8 Code 39 Codabar Industrial 2 of 5 Interleaved 2 of 5 Code 93 Code 128 GS1 128 MSI Plessey Code 11 Po...

Page 153: ...3 mm OCR OCR font OCR A OCR B Imager Image data format Windows Bitmap JPEG Shades of gray 1024 256 16 2 Range of output image Select top bottom column and left right row Resolution of output image Full 1 2 1 4 Interface of output image RS 232C USB COM Baud rate USB COM full speed About 3 sec Resolution Full RS 232C baud rate 115 2 kbps About 40 sec Power Range of operating voltage 4 5 5 5 V RS 232...

Page 154: ...istance SR HD 125 mm UD 78mm Sunlight 100 000 lx or less Vibration 10 Hz to 100 Hz acceleration of 19 6 m s 2 60 minutes per cycle repeat once in each X Y and Z direction Drop Drop 3 times at each 5 faces right left front back and top from a height of 75 cm onto a concrete surface Excluding the part where the interface cable is attached Dust and drip proof IP65 equivalent Physical Features Dimensi...

Page 155: ...Guaranteed Value mm Typical Value mm Near Far Near Far 0 127 mm 5 mil Code 39 0 9 0 8 64 110 53 126 0 254 mm 10 mil Code 39 0 9 0 8 62 209 52 237 0 508 mm 20 mil Code 39 0 9 0 8 84 371 69 433 0 2 mm 7 9 mil Code 128 0 9 0 8 77 165 62 191 0 33 mm 13 mil UPC EAN 0 9 0 8 62 248 50 291 0 169 mm 6 7 mil PDF417 0 9 0 8 57 129 49 146 0 254 mm 10 mil PDF417 0 9 0 8 53 183 42 211 0 169 mm 6 7 mil QR Code 0...

Page 156: ...aranteed Value mm Typical Value mm Near Far Near Far 0 076 mm 3 mil Code 39 0 9 0 8 53 63 45 72 0 127 mm 5 mil Code 39 0 9 0 8 43 102 35 119 0 254 mm 10 mil Code 39 0 9 0 8 62 155 55 179 0 2 mm 7 9 mil Code 128 0 9 0 8 77 138 68 159 0 33 mm 13 mil UPC EAN 0 9 0 8 62 171 48 200 0 127 mm 5 0 mil PDF417 0 9 0 8 46 95 39 109 0 254 mm 10 mil PDF417 0 9 0 8 51 135 46 154 0 127 mm 5 0 mil QR Code 0 9 0 8...

Page 157: ...PCS MRD Guaranteed Value mm Typical Value mm Near Far Near Far 0 076 mm 3 mil Code 39 0 9 0 8 35 56 28 65 0 127 mm 5 mil Code 39 0 9 0 8 35 68 23 82 0 254 mm 10 mil Code 39 0 9 0 8 64 93 53 108 0 33 mm 13 mil UPC EAN 0 9 0 8 66 102 50 120 0 084 mm 3 3 mil QR Code 0 9 0 8 42 45 33 55 0 381 mm 15 mil QR Code 0 9 0 8 29 92 22 109 0 084 mm 3 3 mil Data Matrix 0 9 0 8 43 48 35 55 0 254 mm 10 mil Data M...

Page 158: ...0 mm D except protruding portion Weight Approx 125 g excluding cable Mechanical Drawing Plastic Mask Mounting Holes M3 Depth 3 5 Buzzer Holes 41 1 33 10 9 12 Status LED Mode Key Trigger Key 24 35 9 15 8 18 8 Mounting Holes M3 Depth 3 5 11 2 6 Illumination LED Lens Imaging Lens X X X X X X 13 11 Aiming Lens Unit mm ...

Page 159: ...of serial label attached to the scanner is shown below The details of the label are as follows 6 digits serial number is displayed to SN Address Label Address label attached to the scanner is shown below The details of the label are as follows As per European EMC directive 2014 30 EU X X X X X X ...

Page 160: ...Chapter 11 Appendix NLV 5201 User s Manual 150 1st Sample Codes 11 3 1D Barcode 11 3 1 UPC UPC A UPC A 2 UPC A 5 UPC E UPC E 2 UPC E 5 ...

Page 161: ...Chapter 11 Appendix NLV 5201 User s Manual 151 1st EAN JAN EAN JAN 13 EAN JAN 13 2 EAN JAN 13 5 EAN JAN 8 EAN JAN 8 2 EAN 8 5 ...

Page 162: ...V 5201 User s Manual 152 1st Code 39 Code 39 Code39 Italian Pharmaceutical Code 39 Full ASCII Tri Optic Codabar Codabar Codabar ABC Codabar CX Industrial 2 of 5 Interleaved 2 of 5 Industrial 2 of 5 Interleaved 2 of 5 S Code ...

Page 163: ...Chapter 11 Appendix NLV 5201 User s Manual 153 1st Code 128 Code 93 IATA MSI Plessey IATA MSI Plessey UK Plessey Telepen UK Plessey Telepen Code11 Matrix 2 of 5 Code11 Matrix 2 of 5 ...

Page 164: ... User s Manual 154 1st Postal Code 11 3 2 Chinese Post Matrix 2 of 5 Korean Postal authority Intelligent Mail Barcode POSTNET PLANET Japan Postal Netherland KIX Code Australian Postal UK Postal Royal mail 4 State Mailmark Barcode ...

Page 165: ...V 5201 User s Manual 155 1st GS1 DataBar 11 3 3 GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Expanded Stacked ...

Page 166: ...Chapter 11 Appendix NLV 5201 User s Manual 156 1st GS1 Composite Code 11 3 4 CC A CC B Limited CC A Limited CC B Expanded CC A Expanded CC B Composite GS1 128 CC A CC B CC C ...

Page 167: ...Chapter 11 Appendix NLV 5201 User s Manual 157 1st Composite EAN EAN 13 CC A EAN 13 CC B EAN 8 CC A EAN 8 CC B Composite UPC UPC A CC A UPC A CC B UPC E CC A UPC E CC B ...

Page 168: ...Chapter 11 Appendix NLV 5201 User s Manual 158 1st 2D Code 11 3 5 PDF417 MicroPDF417 Codablock F QR Code Micro QR Data Matrix ECC 200 Aztec Code Aztec Runes Chinese sensible code Maxi Code ...

Page 169: ...WXYZ L898902C 3JPN4209247M16092711234567890 78 Machine readable Visa A V UTOERIKSSON ANNA MARIA L8988901C4XXX4009078F96121096ZE184226B Machine readable Visa B V UTOERIKSSON ANNA MARIA L8988901C4XXX4009078F9612109 Official Travel Documents 1 I UTOD231458907 7408122F1204159UTO 6 ERIKSSON ANNA MARIA Official Travel Documents 2 I UTOERIKSSON ANNA MARIA D231458907UTO7408122F1204159 6 ...

Page 170: ... NLV 5201 User s Manual 160 1st OCR Font Free OCR Edit 11 3 7 OCR A OCR B OCR A Free Edit Enable OCR B Free Edit Enable 4567890 0123456789012 DEFGHIJ 23456CDEFGH 345678 89012345678 FGHIJKLMN 56789012ABCD Free Edit Disable ...

Page 171: ...Chapter 11 Appendix NLV 5201 User s Manual 161 1st ...

Page 172: ......

Reviews: