background image

 F-100 SR 

1st 

 

 

SPECIFICATIONS MANUAL 

 

Detailed View 

5

 

 

Detailed View 

5.1

 

 

Figure 1: Detailed View of F-100 SR 

 

No. 

Name 

Description 

Scan key

 

By pressing this key, the scanner starts reading barcodes. 
Pressing for more than 5seconds, the scanner shifts to read rate mode. 
Ends by pressing key again or inputting trigger signal. 

Status LEDs

 

Indicates reading result and USB communication status. 
In read rate mode, the read rate is indicated by these 3-color LEDs. Refer 
to section 5.2 for details. 

Scan Window

 

Light paths of the imager and LED illumination. Ensure that the lens is free 
from dust and dirt before scanning. 

Mounting holes 

Screw holes that can be used to mount the scanner. Screw hole is M3, 
maximum depth is 4mm and tightening torque is 0.5 Nm. 

 
 

 

Summary of Contents for F-100 SR

Page 1: ...SPECIFICATIONS MANUAL F 100 SR Fixed Position 1D Linear Imager Scanner 80mm width model This manual provides specifications for the F 100 SR fixed position 1D scanner 1st ...

Page 2: ...products that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or inciden...

Page 3: ...F 100 SR 1st SPECIFICATIONS MANUAL Revision History Product Name F 100 SR Edition Date Page Section Description of Changes First 2018 02 21 ...

Page 4: ... Sample 9 8 1 Scan Area 10 8 2 Depth of Field 10 8 3 Printed Contrast Signal PCS 11 8 4 Minimum Resolution 11 8 5 Barcode Width 11 8 6 Pitch Skew and Tilt 12 8 7 Curvature 12 8 8 Motion Tolerance 13 8 9 Interface Specification 14 9 RS 232C Interface D Sub 9pin 14 9 1 9 1 1 Communication Initial Setting 14 9 1 2 Signal Specification 14 9 1 3 Pin Assignment 14 9 1 4 RS 232C D Sub 9pin Circuit 15 9 1...

Page 5: ...ging 23 10 11 Electrical Specifications 23 10 12 Regulatory Compliance 24 11 LED Safety 24 11 1 Product Safety 24 11 2 EMC 24 11 3 RoHS 24 12 Reliability 24 13 Precautions 25 14 Product Display 26 15 Product Label 26 15 1 UL Label 26 15 2 Packaging Specifications 27 16 Individual Packaging Specification RS 232C 27 16 1 Individual Packaging Specification USB 28 16 2 Collective Packaging Specificati...

Page 6: ... 15 Figure 12 RS 232C D sub 9pin Interface Cable 15 Figure 13 Interface Circuit RS 232C Loose End 17 Figure 14 RS 232C Loose End Interface cable 17 Figure 15 USB Plug A Pin Assignment 18 Figure 16 Interface Circuit USB 19 Figure 17 USB Interface Cable 19 Figure 18 Ambient Light Immunity 21 Figure 19 Scan key durability 22 Figure 20 Cable Bending Strength 22 Figure 21 Drop Impact Strength 23 Figure...

Page 7: ...m wide barcodes at a distance of 35mm Installation assistant function The F 100 features a read rate mode in which the reading performance is indicated by a 3 color status LED and the buzzer This mode greatly simplifies the optimal installation in your application Configure Waveform acquisition application To configure the F 100 the Universal Config PC program is available which can generate seria...

Page 8: ...s for this Model Description 3 2 Reading width Focus Symbol Description SR 80mm width model focus distance 35mm WA 120mm width model focus distance 64mm Interface Cable Symbol Description RS232C RS 232C cable external AC adapter power supply spec is connected USB COM USB cable is connected and interface default setting is USB COM USB USB cable is connected and interface default setting is USB HID ...

Page 9: ...ey ISBN code Code 11 Korean Postal Authority code Code 3 of 5 UK Plessey GS1 DataBar RSS S Code Telepen Tri Optic Minimum resolution Code 39 0 125mm PCS 0 9 Skew 15 Pitch Tilt 0 Room temperature room humidity Ambient Light 500 to1000lx Curvature Radius 30 mm EAN JAN 13 Radius 20 mm EAN JAN 8 Barcode width Possible to read Code 39 with 80 mm width and resolution 0 19mm DOF 35 mm Depth of Field Code...

Page 10: ...or residential commercial and light industry environments Immunity Test ESD immunity No destruction Air discharge direct 15 kV Condition IEC61000 4 2 compliant No malfunction Contact discharge direct indirect 6kV Air discharge direct 8 kV Radio frequency electromagn etic field Amplitude modulation Frequency 80 to 1000 MHz Condition IEC61000 4 3 compliant Level 3 V m AM 80 AM Fast transient Voltage...

Page 11: ...essing key again or inputting trigger signal 2 Status LEDs Indicates reading result and USB communication status In read rate mode the read rate is indicated by these 3 color LEDs Refer to section 5 2 for details 3 Scan Window Light paths of the imager and LED illumination Ensure that the lens is free from dust and dirt before scanning 4 Mounting holes Screw holes that can be used to mount the sca...

Page 12: ...ting for USB connection Communication reading error Read rate mode LED indication By pressing the scan key for more than 5 seconds or by sending a serial command the scanner shifts to read rate mode The status LED s then show the read rate according to the following table To exit read rate mode either press the scan key send a serial command or activate the trigger signal Reading rate Less than 50...

Page 13: ...C 5 0 V Range of working voltage 4 75 to 5 25 V Power ripple 100 mVp p max 10 to 100 kHz power supply voltage 5 0 V Current consumption 340 mA Typ 500mA Max during reading operation 100 mA Typ in stand by mode USB Specification 6 2 Input power supply voltage 500 mA High Power Current consumption 340 mA Typ 500mA Max during reading operation 100 mA Typ in stand by mode The current consumption was m...

Page 14: ...l performance is at its best It is recommend to set the barcode at this position especially when reading a high resolution or a low PCS barcode It is possible to read up to 80mm wide barcodes at this distance Figure 2 Reading distance Optical Axis and Dead Zone 7 3 The optical axis is at 6 25 1mm from the bottom of the scanner Please make sure to position the barcode in this area and respect the p...

Page 15: ...V PCS 0 9 or higher Scanning Test More than 630 times success during 700 scans Barcode Test Sample Specified in each section Barcode Test Sample 8 1 Code39 Resolution Code type PCS Barcode width Quiet Zone Digits 1 0mm Code 39 0 9 53mm 20mm 1 0 5mm 54mm 10mm 4 0 25mm 42mm 5 1mm 8 0 19mm 60mm 5 1mm 17 80mm 5 1mm 24 0 15mm 60mm 5 1mm 10 0 125mm 16mm 5 1mm 4 0 19mm 0 45 60mm 5 1mm 17 EAN JAN Resoluti...

Page 16: ...re not satisfied the above reading range may not be reached Please check the readability beforehand and decide appropriate installation conditions Depth of Field 8 3 Code Resolution mm Code type PCS Depth of Field mm Maximum reading width 0 125 below 0 19 Code 39 0 9 35 5 60mm 0 19 1 08 Code 39 0 9 35 10 80mm Note Maximum reading width of the barcode includes the quiet zone 35 5 5 10 10 60 80 Reso...

Page 17: ...e Reflectance of black bar Reflectance of white space Note Be sure to keep the optical window clean without dirt or scratches or it may deteriorate the reading performance Minimum Resolution 8 5 0 125mm Code 39 specified in Section 8 1 Conditions Bar code Above code specified in Section 8 1 Distance 35 5 mm from the front edge of the scanner Angle α 0 β 15 γ 0 Curvature R Barcode Width 8 6 80 mm C...

Page 18: ...he front edge of the scanner Curvature R Angle Pitch β 15 γ 0 Skew Dead zone α 0 γ 0 Tilt α 0 β 15 Figure 6 Pitch Skew and Tilt Curvature 8 8 0 26 mm 13 digit EAN JAN R 30 mm 0 26 mm 8 digit EAN JAN R 20 mm Conditions Barcode Sample EAN JAN PCS 0 9 specified in Chapter 8 1 Distance 35 mm from the front edge of the scanner Angle α 0 β 15 γ 0 Figure 7 Curvature Tilt Pitch Skew α β γ R Barcode 35 Uni...

Page 19: ...the height of the barcode is very small Figure 8 Barcode moving vertically However when scanning barcodes that are moving horizontally as shown in figure 9 the scanning performance will be reduced rapidly at increasing speed Therefore make sure to stop the barcode for a brief moment when the barcode is aligned at the center of the scanner Figure 9 Barcode moving horizontally Note When scanning bar...

Page 20: ... bit 1 bit 9 1 2 Signal Specification Signal names are based on the signals transmitted from the scanner to the host Signal Level RS 232C communication line Signal Name IN OUT Voltage V Mark Space TxD OUT 5 to 15 5 to 15 RxD IN 3 to 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 9 1 3 Pin Assignment Signal Name Pin No Note NC 1 Open not connected TxD 2 RS 232C communication line RxD 3 R...

Page 21: ...9pin 9 1 5 RS 232C D Sub 9pin Interface Cable Cable length 2000 mm Wire conductors diameter AWG28 Cable diameter φ3 8mm Weight Approx 75g Figure 12 RS 232C D sub 9pin Interface Cable Barcode reader main circuit VCC TxD RxD RTS CTS S GND F GND TxD RxD CTS RTS External device F 100 DC JACK φ 3 8 10 50 2000 0 100 10 ...

Page 22: ...e host Signal Level Sequencer Signal loose end only Signal Name IN OUT Voltage V ON OFF Trigger IN 0V to 1 5V 3 0 V to Vcc OK OUT 0 3V 5mA OC output 24V max NG OUT 0 3V 5mA OC output 24V max OC output Open Collector output 9 2 3 Pin Assignment Signal Name Pin No Note TxD Green RS 232C communication line RxD White RS 232C communication line RTS Gray RS 232C communication line CTS Blue RS 232C commu...

Page 23: ...2000 mm Wire cable length 60mm Wire conductors diameter AWG28 Insulator outer deameter 0 58mm Wire length 7mm Cable diameter φ3 8mm Weight Approx 55g Figure 14 RS 232C Loose End Interface cable Barcode reader main circuit VCC DC 5V load Maximum DC 24V TxD RxD RTS CTS OK NG Trigger Trigger S GND F GND TxD RxD CTS RTS External device F 100 2000 φ 3 8 60 7 5 1 Unit mm 50 ...

Page 24: ... version driver While using USB COM and the host COM port is not actively open scan data cannot be sent and F 100 SR will make an error sound 9 3 1 USB Interface Specifications Bus power class 500 mA high power Speed Full speed 12 Mbps Interface HID COM Virtual COM Port Note The USB interface models are bus powered and no AC adapter is needed Do not use the host keyboard when using USB HID to tran...

Page 25: ...ure 16 Interface Circuit USB 9 3 4 USB Interface Cable Cable length 2000 mm Cable diameter φ3 8mm Weight Approx 60g Figure 17 USB Interface Cable Full Speed USB Transceiver Buffers 3 3V Pin No Signal 1 VBUS 2 D 3 D 4 GND Shell FG USB A Connector 2000 φ 3 8 50 1 4 Unit mm ...

Page 26: ...m PCS 0 9 specified in chapter 8 1 Distance 35 mm from the front edge of the scanner Angle α 0 β 15 γ 0 Curvature R Humidity 10 2 Scanning performance is guaranteed when the ambient humidity is within the following ranges Operating Humidity 20 to 85 RH no condensation no frost Storage Humidity 20 to 90 RH no condensation no frost Conditions Barcode EAN JAN 13 Resolution 0 26 mm PCS 0 9 Specified i...

Page 27: ... uniform on the barcode surface Angle α 0 β 15 γ 0 Curvature R Figure 18 Ambient Light Immunity Note Avoid direct or specular reflection from the light source to get the best scanning performance When the illuminance is not uniform on the barcode surface the scanner may fail to read Dust and Drip Proof 10 4 IEC IP42 equivalent Protection against solid objects Level 4 equivalent Protected against s...

Page 28: ...nd repeat this 5 million times Figure 19 Scan key durability Cable Strength 10 6 There shall be no malfunction after the following cable strength test Cable Strength Test Affix the scanner to an immovable object and pull the cable using a force of 24 5N 2 5 kgf static loading for 60 seconds Cable Bending Strength 10 7 There shall be no malfunction after the following cable bending test Cable Bendi...

Page 29: ...epeat this twice for each of X Y and Z direction Drop Impact Strength without packaging 10 10 There shall be no malfunction after the following drop test Drop test Drop the scanner 18 times 3 times at each of 6 orientations from a height of 60 cm onto a concrete floor Figure 21 Drop Impact Strength Drop Impact Strength in individual packaging 10 11 There shall be no sign of malfunction after the f...

Page 30: ... 2013 EMC 11 3 EN 55032 2012 EN 55024 2010 FCC Part 15 Subpart B Class B VCCI CISPR 32 2016 Class B RoHS 12 RoHS compliance RoHS The restriction of the use of certain hazardous substances in electrical and electronic equipment 2011 65 EU Reliability 13 MTBF Mean Time Between Failures 50 000 hours Note This is calculated based on standard operation of the product within the operating environment pa...

Page 31: ...oduct at temperatures outside the specified range Do not pour boiling water on this product Do not throw this product into fire Do not bend the cable at extremely low temperatures 3 Foreign Materials Do not immerse this product in water or any other liquid Do not expose this product to chemicals 4 Others Do not plug unplug the connectors while power is supplied Do not disassemble this product This...

Page 32: ...l attached to the scanner is shown below Serial number is 6 digits from 000001 Refer 17 3 Mechanical Drawing for the allocation Figure 22 Product Label UL Label 15 2 Example of UL label attached to the scanner is shown below Refer 17 3 Mechanical Drawing for the allocation Figure 23 UL Label ...

Page 33: ...model Figure 24 Individual Packaging RS 232C BOX Mirror mat Short side down Place the bundled cable under the mirror mat Put QUICK START GUIDE on top Do not fold at the Barcode position when stick label on to the box BARCODE LABEL for BOX Display for the serial No From 000001 to 999999 Same number as the scanner Number of six digits Continuous Number Twist ties QUICK START GUIDE ENG ...

Page 34: ...Individual Packaging USB BOX Mirror mat Short side down Place the bundled cable under the mirror mat Put QUICK START GUIDE on top Do not fold at the Barcode position when stick label on to the box BARCODE LABEL for BOX Display for the serial No From 000001 to 999999 Same number as the scanner Number of six digits Continuous Number Twist ties QUICK START GUIDE ENG ...

Page 35: ...ed in Japan MADE IN JAPAN Packaged 100 sets into the carton box CARTON BOX Barcode Serial Label Missing Serial Number Label Barcode Serial Label for Packaging Box Stick the labels on both front and back side ofthe box Missing Serial Number Label Attach this label when there are more than 3 labels ofwhich serial numbers are outof order not in a correct sequence C No 3 Missing Serial Number Missing ...

Page 36: ... Approx 45 5 W 20 25 D 19 H mm except protruding portion Weight 17 2 Approx 15 g excluding cable Mechanical Drawing 17 3 Figure 27 Mechanical Drawing Mounting holes M3 Depth4 Scan window Illumination LED lens Imaging lens Scan key Status LED 30 12 8 19 6 25 20 25 45 5 Unit mm ...

Page 37: ...eaved 2 of 5 6 S Code 5 Code 93 1 Code 128 1 GS1 128 EAN 128 5 1 MSI Plessey 3 CD1 CD1 UK Plessey 2 Telepen 1 Matrix2of5 5 IATA 5 CODE11 1 GS1 DataBar Omnidirectional RSS 14 Transmit AI GS1 DataBar Expanded RSS Expanded 1 GS1 DataBar Limited RSS Limited Transmit AI GS1 DataBar Truncated RSS 14 Truncated Transmit AI 1 Reading column Read Not read Not supported 2 Transmit CD column Transmit Not tran...

Page 38: ...conds Trigger input Enable Buzzer durations 50msec Buzzer tone 3 0kHz Buzzer loudness Loud maximum Indicator duration Green LED 200msec 1 In case of the following symbologies because of the prevention of miss decoding the reading times are increased once and redundancy is also increased once Symbology Length Code 39 5 or less Codabar NW 7 All IATA 8 or less Industrial 2 of 5 8 or less Interleaved ...

Page 39: ...Indefinitely ACK NAK time out 1 sec Command header ESC Command terminator CR Response to command Disable 18 3 2 USB Item Default Keyboard language USA USB HID Send new line key after data Enable Send TAB key after data Disable Send key after data Disable Other CDC ACM compliant USB COM The Opticon USB COM driver must be installed on your host to use in USB COM Please contact sales offices for the ...

Page 40: ...ated output voltage 5 0V Rated output current 2 0A Mechanical Drawing Dimensions 19 2 Figure 28 AC adapter Mechanical Drawing Figure 29 DC plug Mechanical Drawing Figure 30 AC plug Mechanical Drawing 71 3 1 1800 45 53 6 1 16 1 0 2 32 6 1 69 0 1 Unit mm 4 0 1 7 EIAJ Voltage type2 EIAJ 2 Unit mm ...