F-100 SR
1st
23
SPECIFICATIONS MANUAL
Vibration Strength (without packing)
10.8
There shall be no malfunction after the following vibration test.
Vibration test:
Increase the frequency of the vibration from 10Hz to 100Hz at an acceleration velocity
of 19.6m/s
2
(2.0 G) for 30 minutes in the non-operating state. Repeat this twice for each of X, Y and Z
direction.
Vibration Strength (in individual packing)
10.9
There shall be no malfunction after the following vibration test.
Vibration test:
Increase the frequency of the vibration from 10Hz to 100Hz at an acceleration velocity
of 19.6 m/s
2
(2.0 G) for 30 minutes in individually packaged state. Repeat this twice for each of X, Y
and Z direction.
Drop Impact Strength (without packaging)
10.10
There shall be no malfunction after the following drop test.
Drop test:
Drop the scanner 18 times (3 times at each of 6 orientations), from a height of 60 cm onto
a concrete floor.
Figure 21: Drop Impact Strength
Drop Impact Strength (in individual packaging)
10.11
There shall be no sign of malfunction after the following drop test.
Drop test:
Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges, and 6
faces, from a height of 150 cm onto a concrete floor.
Electrical Specifications
10.12
Electrostatic discharge*
immunity*
No destruction
±15 kV (air discharge, direct)
No malfunction
±8 kV (air discharge, direct)
±6 kV (contact discharge, direct / indirect)
* Testing method is compliant with IEC-61000-4-2. (150 pf, 330 ohm)
60cm
Concrete floor