installation of the minimum air duct and pipe connection. The height of ceiling should consider the

condensate water discharging height and service room. According the distance of unit’s four

fastening brackets and the height of ceiling joist, make sure the location and height of four sleeves.

The helix length on the sleeve can adjust the level degree of indoor unit and make sure of the

unobstructed condensate water discharge.

2.3 Installation of Ducting Air Line

The ducting air line should be accordance with the local regulation. Make sure that the air line is

insulated on its entire length. Unit should be equipped with muffler by 300-500mm length soft pipe

to reduce the noise. When installing the air line, lay the air outlet line and air return line according

with the static pressure, or it can lead to insufficient air quantity or noise.

2.4 Installation of Outdoor Unit

In order to get maximum cooling performance, the outdoor unit should be installed according to

the following items:

A) The unit installation location should face away from the prevailing wind and avoid air

discharging in that direction.

B ) No obstacle in the location between the air discharging and intake.

C) Install an awning to protect the outdoor unit.

D) Verify that any wall on which the outdoor unit is installed is capable of carrying the unit’s

weight. Do not install on a light unstable structure or vibration.

E) Do not install the unit in a highly polluted area in which the air is contaminated by oil mist,

salt or sulfuric gas.

2.5 Safety Notice

Make sure the outdoor unit location allows easy access for servicing, air inflow and outflow.

Provide minimum disturbance to the owner and nearby neighbors.

Minimum distance between the indoor unit installation location and outdoor unit location, and

minimum quantity of refrigerant pipe bends.

2.6 Tube Connection

The standard tube length is 8/15m. The unit interconnecting tube length can influence the cooling

or heating capacity of unit. Tubing route shall be kept to straight lines as much as possible. When

installing, keep the number of tube bends to a minimum. If bends are necessary, perform them only

by using professional tube benders and not manually; make sure an ideal height difference between

the indoor unit and outdoor unit.

Summary of Contents for 6000 PRO4

Page 1: ...MODELS 6000 PRO4 SPLIT 10500 PRO4 SPLIT 15000 PRO4 SPLIT CAPACITIES 6KW 15KW Operation Instructions and Installation Manual...

Page 2: ...com 1 Contents 1 0 Technical Parameter 2 2 0 Installation Operation and Maintenance 5 3 0 Use of Wire Controller and PCB 8 4 0 System fault protection and code 11 5 0 Operating Tips 12 6 0 Maintenanc...

Page 3: ...ompressor Qty 1 1 1 Type Rotor Scroll Refrigerant R417A Refrigerant charge Connecting pipe 3M See the note on the next page g 1300 0 1800 0 2300 0 Static Pressure Pa 40 0 Noise dB A 50 57 58 Net Dimen...

Page 4: ...r and outdoor unit connecting pipes are connected and leak tested open the valve to vacuum and fill the refrigerant according to the nameplate refrigerant quantity connecting pipe is 3 meters 3 When t...

Page 5: ...http www hicoolopticlimate com 4 1 2 Dimension ELITE 6000 SPLIT ELITE 10500 SPLIT ELITE 15000 SPLIT...

Page 6: ...he stated wire and use the recorded gage wire size 8 or 10 avoid any outside force directly working on the connection end or wire The wrong wire connections can cause a fire If a refrigerant leak occu...

Page 7: ...on location should face away from the prevailing wind and avoid air discharging in that direction B No obstacle in the location between the air discharging and intake C Install an awning to protect th...

Page 8: ...sate water 2 9 Electrical Connections Electrical connection shall be made only by authorized electricians and in accordance with local electrical requirements and codes Power supply should be isolated...

Page 9: ...e MODE for 5 seconds press the MODE again to switch the heating moon symbol night or cooling Special note The control board is optical control In the default state it is cooling during the day and hea...

Page 10: ...ds the hour time flashes and start set the timing start time Press to adjust the hourly timing start time After press the or again the minute time flashes Press to adjust the minute timing start time...

Page 11: ...ter settings Press the SET for 9 seconds to enter the parameter setting menu Press the ON OFF to select System Function Settings Menu Protection Temperature Time Menu Defrosting parameter or Password...

Page 12: ...types of these faults performs corresponding protection processing and displays the corresponding fault code The fault code displays EE XX at the position of the clock 88 88 EE XX Fault Fault code Cau...

Page 13: ...mperature difference is excessive EE 53 The temperature difference between the inlet and outlet water is higher than the value of C3 Stop unit After repair 1 compressor tube temperature protection EE...

Page 14: ...properly connected and power switch is in its ON position After using the unit for 1 or 2 years make sure an integrated maintenance for the unit to guarantee the performance Replaceable Components The...

Page 15: ...http www hicoolopticlimate com 14 Elite 10500 Split Elite 15000 Split...

Reviews: