Installation, Operation and Maintenance

The air-conditioner must be installed by qualified technician. Incorrect installation may lead to

damage, electric shock, and fire or water leak.

Before installing the air-conditioner, please read the “warning and notice” carefully to ensure the

correct installation. After installation, please conduct a trial run and check whether the operation is

normal or not.

Explanation of warning and notice signs

Refers to warning……Neglecting warning may cause a severe accident.

Refers to notice……Neglecting notice may cause injury or damage of the unit.

Verify that any wall on which the outdoor unit is installed is capable of carrying the weight. Do not

install on a light unstable structure susceptible to vibration.

Electrical connection shall be made only by authorized electricians and in accordance with local

electrical requirements and codes.

Insufficient wire capacity or bad circuit structure can cause

creepage or fire.

Make sure the tightness of all wire connection, use the stated wire and use the recorded gage

(wire size 8 or 10 ) , avoid any outside force directly working on the connection end or wire. The

wrong wire connections can cause a fire.

If a refrigerant leak occurs during the installation, please vent air immediately. If the refrigerant

catches fire, it will produce poisonous gas.

Earth leakage breaker must be built in and the ground should be connected during the electrical

connection. If there is no ground connection or imperfect earth, it may lead to electric shock.

Do not let cooling air vent onto your body directly for a long time. Excessively low room

temperature is not good for your health and wastes electricity.

When checking the units, do not revise or replace the electrical components and protection device.

Running without protection device can damage the unit.

If the unit displays the malfunction code, it can be restarted after troubleshooting.

2.1 Warning

In case of air-conditioner failure, immediately cut off power supply and have failure corrected by

specialty maintenance personnel, before restarting the unit or it could cause damage, fire or electric

shock.

2.2 Installation of Indoor Unit

Verify that the indoor unit installation location is capable of carrying its weight, and the

Summary of Contents for 6000 PRO4

Page 1: ...MODELS 6000 PRO4 SPLIT 10500 PRO4 SPLIT 15000 PRO4 SPLIT CAPACITIES 6KW 15KW Operation Instructions and Installation Manual...

Page 2: ...com 1 Contents 1 0 Technical Parameter 2 2 0 Installation Operation and Maintenance 5 3 0 Use of Wire Controller and PCB 8 4 0 System fault protection and code 11 5 0 Operating Tips 12 6 0 Maintenanc...

Page 3: ...ompressor Qty 1 1 1 Type Rotor Scroll Refrigerant R417A Refrigerant charge Connecting pipe 3M See the note on the next page g 1300 0 1800 0 2300 0 Static Pressure Pa 40 0 Noise dB A 50 57 58 Net Dimen...

Page 4: ...r and outdoor unit connecting pipes are connected and leak tested open the valve to vacuum and fill the refrigerant according to the nameplate refrigerant quantity connecting pipe is 3 meters 3 When t...

Page 5: ...http www hicoolopticlimate com 4 1 2 Dimension ELITE 6000 SPLIT ELITE 10500 SPLIT ELITE 15000 SPLIT...

Page 6: ...he stated wire and use the recorded gage wire size 8 or 10 avoid any outside force directly working on the connection end or wire The wrong wire connections can cause a fire If a refrigerant leak occu...

Page 7: ...on location should face away from the prevailing wind and avoid air discharging in that direction B No obstacle in the location between the air discharging and intake C Install an awning to protect th...

Page 8: ...sate water 2 9 Electrical Connections Electrical connection shall be made only by authorized electricians and in accordance with local electrical requirements and codes Power supply should be isolated...

Page 9: ...e MODE for 5 seconds press the MODE again to switch the heating moon symbol night or cooling Special note The control board is optical control In the default state it is cooling during the day and hea...

Page 10: ...ds the hour time flashes and start set the timing start time Press to adjust the hourly timing start time After press the or again the minute time flashes Press to adjust the minute timing start time...

Page 11: ...ter settings Press the SET for 9 seconds to enter the parameter setting menu Press the ON OFF to select System Function Settings Menu Protection Temperature Time Menu Defrosting parameter or Password...

Page 12: ...types of these faults performs corresponding protection processing and displays the corresponding fault code The fault code displays EE XX at the position of the clock 88 88 EE XX Fault Fault code Cau...

Page 13: ...mperature difference is excessive EE 53 The temperature difference between the inlet and outlet water is higher than the value of C3 Stop unit After repair 1 compressor tube temperature protection EE...

Page 14: ...properly connected and power switch is in its ON position After using the unit for 1 or 2 years make sure an integrated maintenance for the unit to guarantee the performance Replaceable Components The...

Page 15: ...http www hicoolopticlimate com 14 Elite 10500 Split Elite 15000 Split...

Reviews: