USER MANUAL
HDMI MATRIX ROUTER : OHM-88
OHM-88 Manual
Page 13
2.6.2
MONITOR OUTPUT SELECTION
– To verify the video source press FUNCTION
key twice.
1) Connect a display to the MONITORING port and any video sources to the HDMI
Input ports on the rear panel.
2) Press the FUNCTION key once
– the LCD displays:
============ Function ===========
Monitor Output sel.
Old Input Channel: 1
New Input Channel:
3) Press Input button of the Input to be monitored.
4) Press
ENTER
to finish the process.
[Note] For OHM-88, Output #1 will be disconnected automatically when monitoring port is
connected and working.
2.6.3
RS-232 BAUD RATE: press FUNCTION three times
Press Input 1 button for 19200
Press Input 2 button for 38400
Press Input 3 button for 57600
Press Input 4 button for 115200
Press
ENTER
to complete the process and return to the User mode.
=========Function Mode========
RS-232 Baud Rate
Old Baud Rate:
19200
New Baud Rate:
19200
[Note] Baud Rate of 19200 bps is highly recommended.
2.6.4
GATEWAY: press FUNCTION four times
The Under Bar mark represents selected and activated.
Pressing Input 1 button repeatedly changes the selected number from 0, 1, 2...9.
The Input 2 button decreases the number.
Input 3 and 4 buttons moves the Under Bar left and right.
=========Function Mode========
Gate Way
192. 168. 000. 001
192. 168. 000. 001
Factory setting is 192.168.000.001.
Press
ENTER
button to complete the process and return to the
User mode
.