background image

OPTICAL SYSTEMS DESIGN

DOC ID: 10102303

OSD361 OPERATOR MANUAL

PAGE 9

3

 

MAINTENANCE

3.1

 

INTRODUCTION

The following section outlines the fault-finding procedure for the OSD361 modems. Please take note of
the following:

V

 

Personnel without appropriate training should not attempt any maintenance except that outlined
below.

 

V

 

If further maintenance is attempted you are warned that every care should be taken to ensure that
internal measurements made while the equipment is operational are taken carefully as some
components within the unit are expensive and may be damaged by failure of any portion of their
support circuitry.

 

V

 

Some components within the unit are ES sensitive and ESD precautions should be taken when
performing maintenance upon the unit.

3.2

 

EXTERNAL INSPECTION

Visually check for the following:

V

 

Check that the correct power source is connected to the power socket.

 

V

 

Check that the video signals are connected to the modem correctly and that the distant  modem has
been terminated correctly to any external equipment.

V

 

Inspect the optical connectors for any contamination and clean using isopropyl alcohol and a lint
free tissue if any contamination is detected.

 

V

 

Check that any external termination resistors are connected if the system configuration requires
them.

3.3

 

ROUTINE MAINTENANCE

V

 

There is no routine maintenance required with the OSD361.

Summary of Contents for OSD361

Page 1: ...OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE...

Page 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10102303 OSD361 OPERATOR MANUAL PAGE 1 OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE Document No 10102303...

Page 3: ...1 WARNING AND PRECAUTIONS 6 2 2 2 OSD361 DRAWINGS AND DIMENSIONS 7 2 2 3 POWER SUPPLY CONNECTIONS 8 2 2 4 SIGNAL CONNECTIONS 8 2 2 5 INDICATOR 8 3 MAINTENANCE 9 3 1 INTRODUCTION 9 3 2 EXTERNAL INSPEC...

Page 4: ...th one of the OSD300 series fiber optic receiver modules will provide CCTV or better quality video transmission at distances of over 5km using standard low cost multimode optical fiber Using the OSD36...

Page 5: ...1 3 PRODUCTS AND OPTIONS There are various options available for the OSD361 as identified in Table 1 below TABLE 1 PRODUCTS AND OPTIONS ITEM DESCRIPTION OSD361 STANDARD FIBER OPTIC CCTV TRANSMITTER M...

Page 6: ...tio 50dB at 30dBm peak received optical power 7 Transmitter Wavelength 850 40nm multimode 1300 40nm singlemode 8 Transmitter Coupled Power 16dBm peak into 62 5 125um multimode fiber 20dBm peak into 10...

Page 7: ...e adequate measures OPTICAL OUTPUT OPERATION Class 1 Class 3A The multimode version of the OSD361 is a Class 1 LED product Wavelength of 850nm and 8dBm power output The singlemode version of the OSD36...

Page 8: ...ND DIMENSIONS The OSD361 should be mounted on an even surface and secured by means of M4 or smaller screws Figure 2 is an outer case drawing showing the required mounting dimensions FIGURE 2 OSD361 CA...

Page 9: ...NNECTIONS Video input signal should be connected to the female BNC connector on the OSD361 using 75 cable terminated in a male BNC connector The optical fiber cable must be terminated with the appropr...

Page 10: ...f any portion of their support circuitry V Some components within the unit are ES sensitive and ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION Visual...

Page 11: ...e for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the r...

Page 12: ...ko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email osdsales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B...

Reviews: