background image

OPTICAL SYSTEMS DESIGN

DOC ID: 10102303

OSD361 OPERATOR MANUAL

PAGE 8

2.2.3

 

POWER SUPPLY CONNECTIONS

The OSD361 requires external DC or AC power. The acceptable DC voltage range is +9 to +18V DC,
and the allowed AC voltage range is 6 to 15V AC, with maximum current draw of 100mA. Power
should be connected to the 2 way socket located at the back of the case. Take care to connect DC
power with the correct polarity: Pin 2 is ground and Pin 1 is positive power. For AC supplies the
polarity is not applicable.

FIGURE 3: OSD361 SIDE VIEWS

2.2.4

 

SIGNAL CONNECTIONS

Video input signal should be connected to the female BNC connector on the OSD361 using 75

Ω

 cable

terminated in a male BNC connector.

The optical fiber cable must be terminated with the appropriate optical connector. Before connection,
inspect the ends of the connectors to ensure that no dust or dirt is present as it could contaminate the
modem connector and result in poor performance.

If it is necessary to clean the cable connectors use isopropyl alcohol and lint free tissue to remove
contamination.

2.2.5

 

INDICATOR

The OSD361 has one LED indicator. The indicator will be ‘green’ to indicate that power to the unit is
“on”.

1

2

3

4

5

6

7

BNC Input

Not Used

Not Used

LED - Power

Power Ground (pin 2)

Power +ve (pin 1)

Optical Output

2

3

4

1

5

6

7

Summary of Contents for OSD361

Page 1: ...OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE...

Page 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10102303 OSD361 OPERATOR MANUAL PAGE 1 OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE Document No 10102303...

Page 3: ...1 WARNING AND PRECAUTIONS 6 2 2 2 OSD361 DRAWINGS AND DIMENSIONS 7 2 2 3 POWER SUPPLY CONNECTIONS 8 2 2 4 SIGNAL CONNECTIONS 8 2 2 5 INDICATOR 8 3 MAINTENANCE 9 3 1 INTRODUCTION 9 3 2 EXTERNAL INSPEC...

Page 4: ...th one of the OSD300 series fiber optic receiver modules will provide CCTV or better quality video transmission at distances of over 5km using standard low cost multimode optical fiber Using the OSD36...

Page 5: ...1 3 PRODUCTS AND OPTIONS There are various options available for the OSD361 as identified in Table 1 below TABLE 1 PRODUCTS AND OPTIONS ITEM DESCRIPTION OSD361 STANDARD FIBER OPTIC CCTV TRANSMITTER M...

Page 6: ...tio 50dB at 30dBm peak received optical power 7 Transmitter Wavelength 850 40nm multimode 1300 40nm singlemode 8 Transmitter Coupled Power 16dBm peak into 62 5 125um multimode fiber 20dBm peak into 10...

Page 7: ...e adequate measures OPTICAL OUTPUT OPERATION Class 1 Class 3A The multimode version of the OSD361 is a Class 1 LED product Wavelength of 850nm and 8dBm power output The singlemode version of the OSD36...

Page 8: ...ND DIMENSIONS The OSD361 should be mounted on an even surface and secured by means of M4 or smaller screws Figure 2 is an outer case drawing showing the required mounting dimensions FIGURE 2 OSD361 CA...

Page 9: ...NNECTIONS Video input signal should be connected to the female BNC connector on the OSD361 using 75 cable terminated in a male BNC connector The optical fiber cable must be terminated with the appropr...

Page 10: ...f any portion of their support circuitry V Some components within the unit are ES sensitive and ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION Visual...

Page 11: ...e for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the r...

Page 12: ...ko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email osdsales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B...