2.2

 

TECHNICAL SPECIFICATIONS 

 
 

TABLE 1: TECHNICAL SPECIFICATIONS 

 

SPECIFICATION 

PERFORMANCE 

Electrical Data Interface 

IEEE802.3z 1000Base-Lx, 1000Base-Sx 
IEEE802.3u 100Base-Fx 

Operating Mode 

Full duplex for 100M/1G 

Store-and-Forward 

IEEE802.3x full-duplex flow control 

Number of Optical Port 
Connectors 

SFP x 28: 24 for 10/1000SFPs Port1-24, 4 for the 1G uplink/trunk ports 

Optical Port Connector Type 

SFP (LC or SC) 

SFP Options 

Short haul, long haul, single fiber operation, etc. 

Please see OSD Datasheets #102100XX and #1021000XX for 100Mbps and 
1Gbps SFP optical modules 

Indicators 

28 x 100M/1G Link/Activity/Speed 

2 x Power 

1 x Status 

Configuration Connector 

Mini USB Console Port 

Alarms 

Four: Two for Power Supply Status 

          Two user definable via the GUI as specified in the user manual 

Alarm Interface 

Four opto-isolated relay drivers via two 4-way 3.5mm terminal blocks 

Control 

System Reset 

Operating Temperature 

-20

°

C to +75

°

C for OSD2790SFPDC 

-20

°

C to +65

°

C for OSD2790SFPAC and OSD2790SFPDAC 

Relative Humidity 

0 to 95% non-condensing 

Power Requirements 

+10 to +36V

DC

 @ 40VA Max for DC version 

90 to 264V

AC

 @ 50VA Max for standard single AC version 

90 to 264V

AC

 @ 55VA Max for optional redundant AC version 

Power Connector 

4 way 5.08mm Terminal Block for DC powered version 

One IEC power inlet module for the standard AC powered version 

Two IEC power inlet modules for the optional redundant AC powered version 

Dimensions of Enclosure (mm) 

443W x 300D x 44H 

1022790SFP01 

 

Summary of Contents for OSD2790SFP

Page 1: ...Quick Start Guide OSD2790SFP MANAGED 24 x 100M 1G SFP 4 x 1G TRUNK UPLINK SFP ETHERNET SWITCH...

Page 2: ......

Page 3: ...I OVERVIEW 11 8 1 CONNECT TO CLI 11 8 2 CLI COMMAND FOR IP CONFIGURATION 12 9 GUI OVERVIEW 13 9 1 DEFAULT SETTING 13 9 2 LOG INTO THE SWITCH 13 9 3 GUI OVERVIEW 13 9 4 IP CONFIGURATION 14 9 5 USERS AU...

Page 4: ...Trunk Uplink SFP Ethernet Switch A number of various SFPs can be used including 100Mbps 1Gbps duplex single fiber and RJ45 Copper Please see OSD SFP datasheets for options available 2 1 2 APPLICATION...

Page 5: ...80Gbps switching backplane IEEE 802 1Q 2005 Rapid spanning tree RSTP IEEE 802 3ad Link aggregation static and LACP DHCP client Port mirroring Security Port based 802 1X Web and CLI authentication and...

Page 6: ...nk Activity Speed 2 x Power 1 x Status Configuration Connector Mini USB Console Port Alarms Four Two for Power Supply Status Two user definable via the GUI as specified in the user manual Alarm Interf...

Page 7: ...ECAUTIONS All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures during servicing of equipment Areas where laser pro...

Page 8: ...4 USB Console Port 5 24 x 100 1000M SFP ports with 100M 1G Link Activity Speed LEDs 6 4 x 1G Trunk Uplink SFP ports with 100M 1G Link Activity Speed LEDs 4 2 REAR PANEL FIGURE 2 REAR PANEL 7 PSU 2 Red...

Page 9: ...wer FIGURE 3 POWER CONNECTION 6 LED Indicators TABLE 2 LED FUNCTION LED Function PSU 1 Red PSU 1 Not connected or faulty Green PSU 1 On PSU 2 Red PSU 2 Not connected or faulty Green PSU 2 On Status Re...

Page 10: ...installing Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP unt...

Page 11: ...STEMS DESIGN DOC ID 10117502 OSD2790SFP QUICK START GUIDE PAGE 11 8 CLI OVERVIEW 8 1 CONNECT TO CLI The Silicon Laboratories CP210x VCP Drivers is required to be installed on the PC before connecting...

Page 12: ...ld jump to the next line 4 Using the Username and password to login the switch Default Username admin Default Password None 8 2 CLI COMMAND FOR IP CONFIGURATION show ip interface brief Display the cur...

Page 13: ...password 9 3 GUI OVERVIEW This Quick Start Guide will only show a few main or important features to get the user started and running the OSD254SFP successfully On the top right hand of the GUI screen...

Page 14: ...dress and Mask Length in the table Choose the management VLAN ID to access that IP in VLAN table if VLAN function is required If the multiple IP addresses are required click Add Interface to add more...

Page 15: ...ATION In the tree map on the left of the GUI expand the Configuration Security Switch Users Click admin to change the current admin account setting If multiple users are required click Add New User PS...

Page 16: ...he configuration on start up 9 7 PORT SPEED SETTING The default port speed settings for the OSD2790SFP is 1Gbps If the user uses 100Mbps SFP devices the unit will have to have those ports manually set...

Page 17: ...tive for all repairs 10 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 10 2 2 OUT OF WARRANTY REPAIRS OSD reserves...

Page 18: ...OPTICAL SYSTEMS DESIGN DOC ID 10117502 OSD2790SFP QUICK START GUIDE PAGE 18...

Page 19: ...OPTICAL SYSTEMS DESIGN DOC ID 10117502 OSD2790SFP QUICK START GUIDE PAGE 19...

Page 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: