11
Put the cable protective cover up to the root of the sensor
cable and secure it to the chain or other device with a cable
tying band.
3
Use a cable tying band to secure.
Cover the cable protective
cover over the end of the
sensor cable.
Caution
・
An opening having the detection window faces immediately
lateral when hanging the sensor.
・
If the sensor inclines at the time of hanging, make horizontal
adjustments by changing a point where the cable is fastened
on the chain wire.
Extension of sensor cable
The standard length of the sensor cable is 9 m. To extend the cable, refer to
the following.
To extend the cable, connection using pull box is recommended.
The cable clamp fits the cable sheath diameter of 6 to 8 mm.
Max. cable length X
Pull box, etc.
Nominal
sectional area
Max. cable length X
0.3 mm
2
20 m
0.5 mm
2
40 m
0.75 mm
2
70 m
1.0 mm
2
100 m