Detectable Speed

Power Input

This unit is designed to detect movement of an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept 

responsibility for any damages or  other consequences resulting from an intrusion. This product confirms to the EMC Directive 89/336 EEC.

PROBLEM

PROBABLE CAUSE

REMEDY

Incorrect power supply voltage.

Faulty wiring to detector. Transmitter is not 
connected to BX-80NR

Wireless transmission does not reach the receiver.

Battery is dead.

Normal Performance. Refer to section "8-2.2. 
BATTERY SAVING TIMER" and "8-2.1.WALK TEST MODE".

No alarm event even though 
someone is walking in 
detection area.

LED blinks continuously

Make alarms even though no 
moving object is in the area

No detection occasionally

Incorrect power supply voltage.

Detector is not installed perpendicular to the ground.

Lower detection area is unnecessarily long.

Lower detection area any object.

Lower detection area is exposed to direct sunlight or 
car light.

There is a heat source (stove or heater, etc.) in the 
area that may cause temperature change. 

There is a moving object (laundrt on clothesline, 
plants, etc.) in the area.

Detection area is not set appropriately.

Sensitivity is set for L(ow)

Set supply voltage for a range of 3 to 9VDC battery.

Rewire alarm correcty.

Check transmitter.

Change battery.

Battery saving timer is working.

Reinstall the detector perpendicular to the ground.

Confirm and reset the detection area.

Remove the reflector or reset the detection area 
reflected light.

Reset the area so it does not receive direct light.

Reset the area or remove the heat source.

Reset the area or remove moving objects.

Reset the area appropriately.

Reset sensitivity for M(edium) or H(igh).

mm(inch)

33(1.30)

9(0.36)

1

5

(0

.5

9

)

Magnetic Contact

MODEL

BX-80NR

Detection Method

Passive Infrared

Coverage

24m (80ft.) (12m(40ft.) on each side)

Detection Zones

4 zone (2 zone on each side)

Sensitivity

2°C at 0.6m/s (3°F at 2.0ft/s)

0.3-1.5m/s (1-5ft/s)

2.5-10VDC

Current Draw   

3mA (Walktest, LED on)  15uA (Standby)

Alarm Period

2.0±1.0 sec.

Relay Output

Tamper Switch

Form C changes when cover removed

Walk Test Mode

ON / OFF

Warm-up Period

Approx. 2 min.

LED Indicator

RF Interference

No Alarm  20 V/m

Mounting

Wall (Indoor/Outdoor)

Mounting Height

Weight

520g (18.4oz)

IP rating

IP55

Accessories

MOUNT SCREW (+4×20) × 2, BATTERY LEAD× 2

Form C-Solid state switch : 10VDC, 0.01A(MAX.)

Disable during normal operation

Enable during WALK TEST or LED SW on

-20°C

+50°C(-4°F

+122°F)

Environmental Humidity

 95%(MAX.)

0.8

1.2m (2.7

4ft.)

ALARM CABLE, 006P CONNECTER CABLE, 

Operating Temperature

No detection occasionally 
when conduct walk tests.

Walk test switch is OFF. 
(Battery saving timer is working.)

Switch ON the walk test mode. Refer to section 
"8-2.1.WALK TEST MODE".

̪

Specifications and design are subject to change without prior notice.

SPONGE PAD,VELCRO TAPE× 2

5

6

(2

.2

0

)

128(5.04)

60(2.36)

M

o

u

n

ti

n

g

 P

it

c

h

 8

3

.5

(3

.2

8

)

2

3

5

(9

.2

5

)

OPTEX CO., LTD.
(JAPAN) 

(ISO9001 Certified by LRQA) 
(ISO14001 Certified by JET)
5-8-12 Ogoto 
Otsu, Shiga 520-0101 
Japan
Tel:+81-77-579-8670  
Fax:+81-77-579-8190
http://www.optex.co.jp/e

OPTEX INCORPORATED
(USA)

13661 Benson Ave., Bldg.C.Chino, 
CA 91710 U.S.A.
Tel:+1-909-993-5770
Fax:+1-909-628-5560
http://www.optexamerica.com

OPTEX (EUROPE) LTD.
(UK)

(ISO 9001 Certified by NQA)
Clivemont Road, Maidenhead,
Berkshire, SL6 7BU 
UK
Tel:+44-1628-631000
Fax:+44-1628-636311
http://www.optexeurope.com 

OPTEX SECURITY SAS 
 (FRANCE)

Batiment Sis 475, Rue Piani 69480 
Amberieux d'Azergues, France
Tel:+33-437-55-50-50
Fax:+33-437-55-50-59
http://www.optex-security.com

OPTEX KOREA CO., LTD.
(KOREA)

1001 Sambu Renaissance-Tower 456,
 Kongduck-Dong, Mapo-Gu, Seoul
 Korea
Tel:+82-2-719-5971
Fax:+82-2-719-5973
http://www.optexkorea.com

OPTEX SECURITY SP.Z O.O.
(POLAND)

ul. Bitwy Warszawskiej 1920 r. 7B,02-366
Warszawa, Poland
Tel:+48-22-598-06-60
Fax:+48-22-598-06-61

10. SPECIFICATIONS & DIMENSIONS

11. TROUBLE SHOOTING

3-9VDC Lithium or Alkaline Battery

Operating Voltage

Set supply voltage for a range of 3 to 9 VDC battery.

                  5913801  06.11.11 

Reviews: