Confirm detection area referring to this section.
8. FUNCTION SETUP
9. WALK TEST
8-1.Sensitivity Adjustment
8-2.DIP Switch Setup
٨
Walk test should be conducted annually.
If LED are not activated when detection fingers are blocked, or LED are activated while there is nothing to detect in detection area,
see section 11 TROBLE SHOOTING.
When greater sensitivity is desired, select [H].
When the installation site is poor(bad conditions) select [L].
Sensitivity [H] is recommended when:
1. The angles of detection areas are changed in horizontal direction.
2. Greater sensitivity is required around the end of detection area(near 12m)
٤
Adjust the detection length by sliding the lower lens as shown.
(The lower areas are adjustable on right and left sides independently.)
Do not press hard.
Remove the LENS HOLDER from the FRONT COVER as described in section 7-1.
The lower lens slides to adjust the detection length. Select the appropriate position
from the guide on the LENS HOLDER (A,B,C, or D).
Make sure to conduct walk tests after changing the position.
The LED light (see section 8-2) can be used to identify detection areas. If the detec-
tion areas are not appropriate, re-adjust the detection length by sliding the lens to a
different position on the LENS HOLDER.
٤
The lower detection finger can be adjusted to control the detection length as
shown below:
[ Detection length setting chart ]
Installation height must be between 0.8m
㨪
1.2m(2.7
㨪
4ft.).
Detection range depends on installation height.
٤
The upper detection finger stays parallel to the ground at all times. The
lower detection finger moves as shown in the section depending on the
position. So, the length of detection is limited by the angle of lower finger,
since both upper & lower fingers have to be blocked at the same time to
activate detector.
Both upper and lower
finger are blocked!
Detection!
Only lower finger is
blocked!
Only upper finger is
blocked!
No
Detection
No
Detection
IMPORTANT
7-2. Detection Length Adjustment
10
5
12
12
40 (ft)
(m)
(m)
40 (ft)
20
30
(m)
12
(m)
3.3
(ft)
1
(ft)
(m)
(m)
3.3
(ft)
(m)
3.3
1
5
20
30
10
20
30
(ft)
(m)
12
40
10
10
10
10
[ POSITION B ]Side view of detection
[ POSITION D ]Side view of detection
[ POSITION C ]Side view of detection
[ POSITION A ]Side view of detection
3.3
1
1
(ft)
5
0
30
(ft)
40
20
5
10
10
0
0
0
0
0
0
0
(single side)
(single side)
(single side)
(single side)
Next, make sure to switch off the WALK TEST MODE. Then, conduct walk tests near by the windows to be protected by BX-80NR and
confirm if it alarms. If there is no alarm during the walk tests, the detection areas are not developed properly on horizontal direction.
In this case, please see section 7 AREA SETUP and confirm if the areas are properly developed.
POSITION
MAX DETECTION LENGTH m(ft)
Standard
*
㧭
㧮
㧯
㧰
12.0
8.0
5.0
2.0
(40.0)
(26.7)
(16.7)
(6.7)
10.0 - 15.0
(33.3 - 50.0)
6.0 - 10.0
(20.0 - 33.3)
4.0 - 6.0
(13.3 - 19.8)
1.5 - 3.0
( 5.0 - 9.9)
*The maximum detection length may vary as above due to
environmental thermal conditions.
Instration height=1m(3.3ft)
3
ON
1 2
O
N
O
F
F
5
s
T
E
S
T
1
2
0
s
N
O
R
M
.
3. LED Indicator
Select LED Indicator status : [ON] or [OFF].
2. BATTERY SAVING TIMER
Alarm output activations are limited by a timer selection 5 or 120 seconds.
Even if there are continuous alarm events, the alarm is generated only once
in the timer period which can be 5 or 120 seconds.
1. WALK TEST MODE
120s : The factory set timer position.
5s : If frequent alarm transmission is requires select the "5s" option.
Battery life will be shortened when using the "5s" setting.
TEST (Walk test mode)
LED will light when detector is tripped.
Alarm will be generated instantly on detection.
NORM. (Normal operation : Battery saving mode)
LED is off. (When LED SW is OFF.)
SEN
S
L
M
H