PHOTOELECTRIC DETECTOR

PHOTOELECTRIC DETECTOR

CONTENTS

1 INTRODUCTION

  1-1 BEFORE YOUR OPERATION ............................... 2

 1-2 PRECAUTIONS...................................................... 3

2 PARTS IDENTIFICATION

............................................ 3

3 INSTALLATION

 3-1 NOTE...................................................................... 4

 3-2 INSTALLATION METHOD .................................... 4

4 WIRE CONNECTION

................................................... 6

5 ALIGNMENT

 5-1 OPTICAL ALIGNMENT .......................................... 7

 5-2 BEAM INTERRUPTION TIME................................ 8

 5-3 SELECTABLE BEAM FREQUENCIES 

< AX-100/200TF ONLY >....................................... 8

6 WALK TEST

................................................................. 9

7 SPECIAL FUNCTION < AX-100/200TF ONLY >

  7-1 ENVIRONMENTAL DISQUALIFICATION.............. 9

 7-2 ALARM MEMORY.................................................. 9

8 OPTIONAL ACCESSORIES

  8-1 HEATING UNIT : HU-3......................................... 10

  8-2 BACK COVER : BC-3........................................... 11

  8-3 POLE SIDE COVER : PSC-3 ............................... 11

9 TROUBLESHOOTING

............................................... 12

10 SPECIFICATIONS

  10-1 SPECIFICATIONS.............................................. 13

 10-2 DIMENSIONS & OPTION................................... 14

INSTALLATION INSTRUCTIONS

FEATURES

No.59-2419-1 1701-31

No.59-1282-7 0904-30

AX-70TN, AX-130TN, AX-200TN

AX-100TF, AX-200TF

< AX-70/130/200TN, AX-100/200TF >

•High-performance waterproof structure

•Horizontal alignment dial for user-friendliness

•Adjustable beam interruption period

•Tamper function

•Optional Accessories : Heating unit (HU-3), Back cover (BC-3), 

Pole side cover (PSC-3)

•UL Listed

< AX-100/200TF ONLY >

•4 selectable  beam frequencies

•LED indicator for fine beam alignment level

•D.Q. circuit (Environmental disqualification) 

•Alarm memory

AX-200TN

60 m / 200 ft.

30 m / 100 ft.

4 selectable beam 

frequencies 

60 m / 200 ft.

AX-100TF

AX-200TF

Model

Detection range

Feature

20 m / 70 ft.

40 m / 130 ft.

Standard model with 

detection range 

60 m / 200 ft.

AX-70TN

AX-130TN

UL

AX-70TN, AX-130TN, AX-200TN

AX-100TF, AX-200TF

Summary of Contents for AX-100TF

Page 1: ...NS 10 1 SPECIFICATIONS 13 10 2 DIMENSIONS OPTION 14 INSTALLATIONINSTRUCTIONS FEATURES No 59 2419 1 1701 31 No 59 1282 7 0904 30 AX 70TN AX 130TN AX 200TN AX 100TF AX 200TF AX 70 130 200TN AX 100 200TF High performance waterproof structure Horizontal alignment dial for user friendliness Adjustable beam interruption period Tamper function Optional Accessories Heating unit HU 3 Back cover BC 3 Pole s...

Page 2: ...cally for safe use If any problem is found do not attempt to use the product as it is and have the product repaired by a professional engineer or electrician Do not touch the unit base or power terminals of the product with a wet hand do not touch when the product is wet with rain etc It may cause electric shock Warning Caution Failure to follow the instructions provided with this indication and i...

Page 3: ...cates prohibition This symbol indicates recommendation Avoid aerial wiring Receiver Transmitter other model Transmitter 1 m 3 3 ft 2 PARTS IDENTIFICATION View Finder Terminals Transmitting Condition LED Transmitter Alarm Indicator LED Receiver Waterproof Plug Selection Dip Switch See 4 WIRE CONNECTION 5 2 BEAM INTERRUPTION TIME and 7 2 ALARM MEMORY AX 100 200TF ONLY Alarm Memory Receiver See 7 2 A...

Page 4: ...ation angle In case to be installed in these angles as below maximum detection range shall be half of the original detection range The attenuation of beam by the edge of the cover about 1 m 3 3 ft When removing the cover do not put your fingers on the hood which may cause damage 1 Loosen the cover lock screw to detach the cover 2 Turn the optical unit and open the waterproof plug 3 Loosen the unit...

Page 5: ... for leakage prevention Align the optical axis to the maximum receiving level according to 5 1 OPTICAL ALIGNMENT Then check for the operation with reference to 6 WALK TEST Put the cover and tighten the cover lock screw Make sure that the cover edge has reached the line prepared on the side of the unit base See the figure left Wiring guide should be as above Knockout needs to be opened with a nippe...

Page 6: ...ity 28VDC and 0 2A max Receiver Receiver Tamper output It opens when cover is removed Non voltage contact output Contact capacity 28VDC and 0 1A max Power input 10 5 to 28VDC Power input 10 5 to 28VDC Power input 10 5 to 28VDC Power input 10 5 to 28VDC Tamper output BE Model only it opens when cover is removed Non voltage contact output Contact capacity 28VDC and 0 1A max Transmitter Transmitter A...

Page 7: ...oltmeter until it reaches maximum monitor output over Good level Fine adjustment with monitor jack Receiver Receiver Alarm Indicator View Finder For Horizontal Vertical alignment refer to the following illustration AX 100 200TF Alarm Indicator Light interrupting Light receiving ON red fast flicker slow flicker OFF Monitor output Realign Less than 1 0V Fair 1 0V or more Good 2 0V or more Excellent ...

Page 8: ... top of one another See following example The upper unit is set on channel 1 while the lower is on channel 3 channels 2 and 4 could have also been used Note CH msec 500 250 100 50 Interruption time Switches 50 ms 100 ms 250 ms 500 ms 50msec 100msec 500msec 250msec Running 2 4m s Jogging 1 2m s Walking 0 5m s Slow movement 0 3m s AX 70 130 200TN AX 100 200TF Selection Dip Switch Selection Switch Se...

Page 9: ...ple COM N C N C N C Power 12VDC N C Alarm Alarm Power 12VDC Alarm1 Alarm2 N C D Q transmitter transmitter receiver receiver Control Panel Control Panel External Relay COM COM N C D Q COM COM Power GND Load N C Alarm N O A C B Alarm Indicator Alarm Output Cancellation D Q Alarm 7 SPECIAL FUNCTION AX 100 200TF ONLY D Q will send a trouble signal which indicates the adverse weather condition when the...

Page 10: ...ring holes with the waterproof material included so that there is no gap between the wire and the surrounding plastic Repeat it for both holes Rotate the optical unit approximately 45 away from the knockout area that you cut out in Step 1 8 OPTIONAL ACCESSORIES Power voltage of 24 VAC DC is required to use the heating unit 8 1 HEATING UNIT HU 3 Knockout Knockout cutoff section Optical Unit Front v...

Page 11: ...INSTALLATION 8 2 BACK COVER BC 3 Unit Base Mounting Screw Wiring distance Wire Size AWG18 0 83mm2 AWG16 1 31mm2 AWG14 2 09mm2 Wiring Distance 300 m 1000 ft 500 m 1700 ft 800 m 2600 ft UL Listed applications the heating unit was not investigated with the models AX 70 130 200TN AX 100 200TF Back Cover Unit Base Cut with cutter Knockout Mounting plate lock screws for main unit Pole lock screws for ma...

Page 12: ... beams from other transmitters Disconnection in power line Inappropriate wiring distance or wire diameter Check the voltage and make sure that it is between 10 5 and 28VDC Check the voltage and make sure that it is between 10 5 and 28VDC Check the wiring Repair the required Contact the distributor or installer See 5 1 OPTICAL ALIGNMENT and make realignment Remove any object blocking the beam See 5...

Page 13: ...0 m 2000 ft 300 m 1000 ft 600 m 2000 ft 38mA max T 17mA R 21mA 41mA max T 20mA R 21mA 45mA max T 24mA R 21mA 44mA max T 6mA R 38mA 48mA max T 10mA R 38mA Maximum arrival distance Detection method Selectable beam frequency Interruption period Power input Current draw Transmitter Receiver Alarm output Output Alarm period D Q output Tamper output Alarm indicator Receiver Indicator Power Transmitter A...

Page 14: ... http www optex com pl OPTEX PINNACLE INDIA PVT LTD India URL http www optex net in en sec OPTEX KOREA CO LTD Korea URL http www optexkorea com OPTEX DONGGUAN CO LTD SHANGHAI OFFICE China URL http www optexchina com OPTEX Thailand CO LTD Thailand URL http www optex net th th Copyright C 2017 OPTEX CO LTD EU contact information Manufacturer OPTEX CO LTD 5 8 12 Ogoto Otsu Shiga 520 0101 JAPAN Author...