ENGLISH
FRANÇAIS
DEUTSCH
IT
ALIANO
ESP
AÑOL
PORTUGUÊS
EN-8
Initial setting is at 50ms for normal work.
According to the speed of a supposed target you select one specific setting out of 4 steps.
Set the interruption time adjustment switches of the Receiver according to the speed of the human object to detect.
The selectable beam frequencies can be used to avoid unwanted crosstalk that can occur
when using multiple photo-beams for long distance or beam stacking applications.
• To select between 4 separate beam frequencies, use the switch provided.
• Make sure the receiver and transmitter that are facing each other are set to the same channel.
• More than double stacked application is not possible.
More than double stacked apprication is not possible.
Note>>
Always switch the frequencies TWO channels apart when stacking units on top of one another
(See following example) .
The upper unit is set on channel 1 while the lower is on channel 3.channels 2 and 4 could have
also been used.
Note>>
(CH)
(msec)
500
250
100
50
Interruption
time
Switches
50 ms
100 ms
250 ms
500 ms
50msec
100msec
500msec
250msec
Running
(2.4m/s)
Jogging
(1.2m/s)
Walking
(0.5m/s)
Slow movement
(0.3m/s)
[AX-70/130/200TN]
[AX-100/200TF]
Selection Dip Switch
Selection Switch
Selection Switch
5-2
BEAM INTERRUPTION TIME
5-3
4 SELECTABLE BEAM FREQUENCIES < AX-100/200TF ONLY >
Tr-A
Tr-B Tr-C
Re-A Re-B
Re-C
Tr-A
Tr-B Tr-C
Re-A Re-B
Re-C
1. Long distance protection
3. Perimeter protection
4. Double stacked long perimeter protection
<EXAMPLE>
2. Double stacked long distance protection
Ch1
Ch1
Ch1
Ch1
Ch2
Ch2
Ch3
Ch3
Ch3
Ch3
Ch4
Ch4
Ch1
Ch1
Ch1
Ch1
Ch3
Ch3
Tr-A= Transmitter “A”
Re-A = Receiver “A”
Keys>>
1:OFF, 2:OFF
1:OFF, 2:ON
1:ON, 2:OFF
1:ON, 2:ON
Tr(Ch1)
Tr(Ch3)
Tr(Ch2)
Tr(Ch4)
Re(Ch1)
Re(Ch3)
Re(Ch2)
Re(Ch4)
Re(Ch2)
Re(Ch4)
Tr(Ch2)
Tr(Ch4)
Tr(Ch1)
Tr(Ch3)
Re(Ch1)
Re(Ch3)
Tr(Ch1)
Tr(Ch3)
Tr(Ch1)
Tr(Ch3)
Re(Ch1)
Re(Ch3)
Re(Ch3)
Re(Ch1)