OPERATION EXAMPLE
1. Set both Temperature Controllers to 160 Degrees F.
2. Set Vacuum Dwell to 30 Seconds.
3. Set Pressure Dwell to 20 Seconds.
4. Place Prelaminated product on Platen.
5. Slide Hold-Down Device into place.
6. Slide Drawer into Vessel.
7. Momentarily depress the “CYCLE START” button.
8. Machine will complete one “AUTOMATIC CYCLE”.
9. “CYCLE READY” Light Illuminates.
10. Slide the drawer out, and remove substrate.
NOTE:
If at any time the operator desires to exit the cycle, depress the “CYCLE-
RESET” button and machine will return to Step 0. Atmospheric pressure will be
vented to the chamber and the drawer may be opened.
NOTE:
If at any time the operator wishes to hold the cycle at a given step, depress
the “CYCLE STOP” button. The machine program will hold at the present step
indefinitely. To resume the program sequence, press “CYCLE START” button.
NOTE:
If the operator wishes to step through the program manually, depress the
“SINGLE STEP” button. Unit will advance one program step with each pressing
of the button, maintaining that step’s conditions after completion of the timer
setting.