background image

Fiber Ethernet Switch Transceivers Product Manual (Product Manual) 

DashBoard

Menus 

••••

 4-1

Configuration

In This Chapter

This chapter provides a general overview of the user controls and configuration options available for your F iber
Ethernet Switch Transceiver.

The following topics are discussed:

 

Card Overview

 

Control and Monitoring Features

 

Configuring a VLAN

 

Enabling Trunking

 

Enabling Alarms

Summary of Contents for 9450GT

Page 1: ...9450GT Fiber Ethernet Switch Transceivers Product Manual 9450GT OM Version 1 0...

Page 2: ...e following Canadian Patents 2039277 1237518 1127285 Other patents pending Notice The material in this manual is furnished for informational use only It is subject to change without notice Trademarks...

Page 3: ...minor equipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic devi...

Page 4: ...ld void the user s authority to operate this equipment CANADA This Class A digital apparatus complies with Canadian ICES 003 Cet appariel numerique de la classe A est conforme a la norme NMB 003 du Ca...

Page 5: ...d fiber handling practices Safety Measures for Operation During normal operation of this product heed the following safety measures Do not stare at or into broken or damaged fibers Do not stare at or...

Page 6: ...ent and to diminish the need for the extraction of natural resources you are encouraged to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end...

Page 7: ......

Page 8: ...Sensitivity Models 3 2 9450GT Functional Block Diagram 3 3 Cabling for the 9450GT 3 4 9450GT Cabling Overview 3 4 9450GT Technical Specifications 3 5 9450GT 20 40 80Series 3 5 9450GT CWDM Series 3 6 C...

Page 9: ...ii Contents Fiber Ethernet Switch Transceivers Product Manual V1 0 Warranty and Repair Policy 5 3 Contact Cobalt Digital Inc 5 4 Visit us at the Cobalt Digital Inc website 5 4...

Page 10: ......

Page 11: ...Ethernet Switch Transceivers Product Manual Introduction 1 1 Introduction In This Chapter This chapter contains the following sections Overview Features User Interfaces Documentation Terms and Conven...

Page 12: ...t fiber infrastructure from one wavelength to up to 16 wavelengths on a fiber High Sensitivity Series Some Fiber Ethernet Switch Transceivers are equipped with high sensitivity SFPs for increased link...

Page 13: ...sed on individual ports Allows for port disabling Up to seven available ports using a combination of ethernet via RJ45 connections fiber optic ports and a GigE internal link to the MFC 8322 N card in...

Page 14: ...rk Controller Card refer to the MFC 8300 Series Product Manual Card edge Controls The front edge of the Fiber Ethernet Switch Transceiver cards have an LED indicator for power status LEDs on the rear...

Page 15: ...the MFC 8322 N and MFC 8322 NS unless otherwise noted OG3 FR series refers to all versions of the OG3 FR frames and any available options unless otherwise noted openGear frame refers to the 8321 serie...

Page 16: ...1 6 Introduction Fiber Ethernet Switch Transceivers Product Manual Product Manual...

Page 17: ...er This chapter provides instructions for installing the rear module s for the Fiber Ethernet Switch Transceivers installing the cards into the frame cabling details and updating the software The foll...

Page 18: ...cise proper grounding precautions when working on circuit boards and related equipment Unpacking Unpack each Fiber Ethernet Switch Transceiver you received from the shipping container and ensure that...

Page 19: ...wax sheet You will need to remove this wax sheet before applying the label in order that the label can be affixed to the rear module surface Affix the supplied Rear Module Label to the BNC area of the...

Page 20: ...of a connected fiber or device transmitting an optical signal The transmitted light is not in the visible spectrum and may cause permanent eye damage Turn off all laser sources before disconnecting de...

Page 21: ...e refer to the MFC 8300 Series Product Manual Ethernet Cabling Overview The exact steps for connecting to your facility via an ethernet network depends on the network requirements of your facility You...

Page 22: ...u This menu provides a list of the compatible cards based on the card selected in step 2 Specify the card s to upload the file to by selecting the check box es for the cards you wish to upload the fil...

Page 23: ...ter This chapter provides the cabling designations and the technical specifications for the 9450GT Single Link Ethernet Fiber Transceivers Note that specifications are subject to change without notice...

Page 24: ...80KM LC Dual Fiber 80km 1550nm transmitter and wideband receiver CWDM and High Sensitivity Models Options are also available with Coarse Wavelength Division Multiplexing CWDM transmitters with a stand...

Page 25: ...nual Product Manual 9450GT Setup 3 3 9450GT Functional Block Diagram This section provides a functional block diagram that outlines the workflow of the 9450GT series regardless of the model type Figur...

Page 26: ...ar Module Each rear module occupies two slots and accommodates one card This rear module provides one single mode optical input one single mode optical output and four RJ45 Ethernet 10 100 1000 ports...

Page 27: ...the 9450GT 20 9450GT 40 and 9450GT 80 Table 3 6 9450GT Technical Specifications Category Parameter Specification Number of Inputs 1 Number of Outputs 1 9450GT 20 1310nm 9450GT 40 1310nm Nominal Wavele...

Page 28: ...9450GT 51 1510nm 9450GT 53 1530nm 9450GT 55 1550nm 9450GT 57 1570nm 9450GT 59 1590nm Nominal Wavelength 9450GT 61 1610nm 9450GT xx CWDM series 5dBm to 0dBm Tx Power 9450GT xxH CWDM series 7dBm to 2dB...

Page 29: ...ion In This Chapter This chapter provides a general overview of the user controls and configuration options available for your F iber Ethernet Switch Transceiver The following topics are discussed Car...

Page 30: ...er Ethernet Switch Transceivers use a blind mate LC UPC connector to interface with the Rear Modules The rear module remains passive while allowing for the Fiber Ethernet Switch Transceiver to be repl...

Page 31: ...dge of each Fiber Ethernet Switch Transceiver includes LED indicators for alarms and communication activity Refer to Figure 4 2 for the location of these LEDs on the card edge Figure 4 2 Fiber Etherne...

Page 32: ...iber signal on the specified SFP is functioning correctly and that no anomalies have been detected Green When lit green this LED indicates the port speed is 1Gbps Orange When lit orange this LED indic...

Page 33: ...LED indicates communication activity is occurring on the specified RJ45 port ETHERNET PORT LINK ACTIVITY Off When off this LED indicates an invalid link is detected on the specified RJ45 port Verify...

Page 34: ...nternal Loop issue cannot occur with an MFC 8322 S or DFR 8321 series frames Troubleshooting a Loop When a loop is created the Fiber Ethernet Switch Transceiver may automatically detect the loop and d...

Page 35: ...RJ45 Link Fails check box es to enable the card to report when the specified RJ45 connector on the rear module loses network connection 3 Select the required Fiber Link Fails check box es to enable th...

Page 36: ...ection you wish to monitor Incompatible Rear Module Monitoring You can choose to enable the card to report when an unsupported rear module is installed with your card This alarm is reported in the HW...

Page 37: ...his Chapter This chapter briefly summarizes the menus items and parameters available from the DashBoard Control System for the Fiber Ethernet Switch Transceiver Note that default values are indicated...

Page 38: ...he corresponding alarm is disabled in the Alarm Enable tab RJ45 Link Status Link Failure Red The link for the specified port is invalid fails and the corresponding alarm is enabled in the Alarm Enable...

Page 39: ...Optical Module is drawing power outside the SFP recommended range Tx Power High Red a Tx Power Low Red a The transmitter component of the Optical Module is drawing power outside the SFP recommended r...

Page 40: ...settings in the Alarms Enable tab Voltage mV Measured input voltage Current mA Measured current consumption of card CPU headroom Processing power available RAM available On board processing memory av...

Page 41: ...Fiber Ethernet Switch Transceivers Product Manual Product Manual DashBoard Menus 4 13...

Page 42: ...umbo packet size regardless of CRC or alignment errors RX Errors Reports the number of packets received by the specified port that have either an FCS error or an alignment error RX Dropped Reports the...

Page 43: ...runk Group 1 Selected Includes the specified ports into Trunk Group 2 Trunking RJ45 Fiber Trunk 2 Cleared Excludes the port from Trunk Group 2 Selected Includes the specified port into Virtual LAN Gro...

Page 44: ...tab to report when the GigE connection to the OG3 FR midplane experiences an error condition Internal Link Fails Cleared Disables this alarm Selected The HW Status field in the Hardware tab reports wh...

Page 45: ...Bm TX Power Low Cleared Disables this alarm for the specified port Selected Enables the corresponding Optical Rx Power field in the Signal tab to report when the optical receiver power of the Optical...

Page 46: ......

Page 47: ...net Switch Transceivers Product Manual Product Manual Service Information 5 1 Service Information In This Chapter This chapter contains the following sections Troubleshooting Checklist Warranty and Re...

Page 48: ...e presence of power If the power LED is not illuminated verify that the power cable is connected to a power source and that power is available at the power main Confirm that the power supplies are ful...

Page 49: ...e product by completing and returning a product registration form In the event of a warrantable defect the purchaser shall notify Cobalt with a description of the problem and Cobalt shall provide the...

Page 50: ...pport 217 344 1243 PHONE Fax 217 344 1245 General Information Info cobaltdigital com E MAIL Sales Information Sales cobaltdigital com Cobalt Digital Inc 2406 East University Avenue Urbana IL 61802 USA...