background image

 

 

 

Ontech GSM 9020 

 

 

User Manual 

 

 

a

ENGLISH

a

 

 

 

Summary of Contents for GSM 9020

Page 1: ...Ontech GSM 9020 User Manual aENGLISHa...

Page 2: ...1234 1 0 Also the buttons to be pressed when using a telephone in tone mode not pulse is shown in this way Text in italic indicates a menu in your mobile phone for example Contacts Quotation mark shal...

Page 3: ...the relay with SMS 13 The position of the relay after a power failure 14 Alarm 14 Wired alarm 15 Wireless alarm detectors 16 Delayed activation of alarm detector 17 Activation of relay when alarming A...

Page 4: ...kup battery is connected 27 Short range radio extra relays 28 Reference 29 SMS from the unit 29 Alarm SMS Status SMS 29 SMS about power supply 30 SMS about GPS 30 SMS showing the SIM card settings 31...

Page 5: ...NC Can be programmed to activate relay when alarms Wireless alarm detectors will be available during 2009 Internal temperature sensor reports temperature External temperature sensor with high accurac...

Page 6: ...ose Contacts in the mobile phones menu a Create a new entry Name it PINCODE b In the field for telephone number enter your personal four digit number This number is the PINCODE you must enter each tim...

Page 7: ...ble to set a delayed activation for an alarm detector This is for giving you time to deactivate the alarm before the unit is sending an alarm 2 Create a new contact Name it DELAYX X is the ID of the a...

Page 8: ...t alarms when the ordinary power is disconnected It is possible to set a delay for this alarm 2 Create a new contract and name it POWERFAIL i In the telephone number field write the number of minutes...

Page 9: ...ckup battery If you want to use an internal backup battery see page 26 you should install this before the physical installation The backup battery is optional and is not included in the standard packa...

Page 10: ...ls Do not pull longer as there is a risk for the flex cable to the membrane switch to disconnect 4 Install the SIM card see picture a The upper part of the SIM card holder is moved to left until you h...

Page 11: ...reless alarm detectors See page 28 c Switch 6 Set to ON if you do not use the short range radio and wants to turn it off in order to decrease power consumption See page 25 d Switch 8 Set to ON if you...

Page 12: ...u shall use main power contact a professional electrician Normally Open Connect the cables to connector 2 and 3 on terminal B When activated the relay will connect the two connectors and when deactiva...

Page 13: ...th another operation without calling up again When you have completed all operations then hang up Control the relay with SMS 1 Activate the relay send an SMS to the unit with the following text ABCD 1...

Page 14: ...AB will start to sell different wireless alarm units which communicate with Ontech 9020 Up to 7 different alarm detectors can be connected The wireless alarm detectors planned are A Motion detector B...

Page 15: ...or on the terminal has the following markings 0V Ground A Alarm input A B Alarm input B 12 Voltage 12 V Switch from Normally Open to Normally Closed mode Locate the DIP switch see Fig 1 Factory defaul...

Page 16: ...ed NC mode Wireless alarm detectors In the 2009 Ondico AB will market wireless alarm detectors These can be easily connected to work together with Ontech GSM 9020 Up to 7 different detectors can be co...

Page 17: ...evel is too high the relay is activated and turns on a pump The function is activated by adding a contact on the SIM card and name it ALARMRELAY In the telephone number field write 1 see page 7 The fu...

Page 18: ...will be published on our web site www ondico se Tip If you want to know if the alarm is turned on or off you can check this by requesting a status SMS from the unit see page 29 When the alarm is turn...

Page 19: ...erature sensor the second number refers to external temperature sensor if connected If not connected will be written instead If there is an asterisk for example 24 2 before the number this indicates t...

Page 20: ...icate 1 2 degrees higher than normal due to heat produced by the relay If you wish higher accuracy 1 we recommend you to purchase the external temperature sensor Ontech Temp Sensor 9020_002 If you wis...

Reviews: