MD-101A
E F B A L A D J U S T
E F B A L X X M O - W
E F B A L X X M O - W
E F B = X X S AV E
E F B A L A D J U S T
A
B
TE
VC
VC
E F B A L M O - W
4
FL Display
ADJUSTMENT PROCEDURES-6
Adjustment of traverse (EF balance)
[Preparation]
(1) Connect oscilloscope to
TE
and
VC
on Extended JIG.
[NOTE]
Do not connect the
VC
to the GND of the unit.
To MD mechanism
(2) Loading the MO disk to the unit.
Oscilloscope
Extended JIG
Part No. 0J12
[Adjustment]
(1) Turns the
JOG
knob, and select for the display
of FL tube to be set to
EFBAL ADJUST
.
(2) Press the
JOG
button .
(3) Turn the
JOG
knob, adjust so that reading
of the waveform currently observed with the
oscilloscope should be as follows.
(4) Press the
JOG
knob.
(5) Remove the oscilloscope and extended
JIG from MD mechanism.
(6) Take out disk from the unit by pressing
the
EJECT
button.
Adjusted so that it may grow into
A=B
.