2.3.4 Installation of Meters with Packing Gland Connection (No Insertion Tool)*
Use the following formula to determine insertion depth for meters with a packing gland
connection (NPT and flanged) without an insertion tool.
Figure 6. Flow Meter with Removable Insertion Tool
Example:
To install the F-1500 flow meter with a standard probe (S = 28.67) into a
14 inch schedule 40 pipe, the following measurements are taken:
F = 3 inches
R = 5 inches
t = 0.438 inches
The example insertion length is 20.23 inches.
*All dimensions are in inches.